The Value of Polyp Surface Pattern Recognition in the Identification of Neoplasia: a Prospective Study
NCT ID: NCT01182623
Last Updated: 2023-04-10
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
260 participants
OBSERVATIONAL
2009-12-31
2010-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Computer Assisted Optical Assessment of Small Colorectal Polyps
NCT02522702
Predictors of Unsuccessful Endoscopic Mucosal Resection of Complex Colon Polyps
NCT02782793
Endoscopic Surveillance in Serrated Polyposis Syndrome and Low-risk of Advanced Neoplasia
NCT04906343
Randomised Comparison of 2 Cold Snare Polypectomy Techniques
NCT02208401
Accuracy of the Optical Diagnosis of Small Colonic Polyps Using the Nice Classification
NCT02009774
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
1. Hyperplastic, which have negligible potential to turn into cancer and if left would cause no harm. These account for around one third of all small polyps encountered
2. Adenomas, which can turn into cancer and should be removed
3. Polyp cancers, which should be either biopsied or removed completely
The management pathway for polyps \>10mm is very simple as they are either likely to be adenomas which need removal or cancers which need a biopsy and tattoo. There is a rare possibility of these big polyps being hyperplastic / serrated adenomas and given the risk of malignant transformation, they need removal as well.
It has been traditionally felt that hyperplastic polyps cannot be separated clinically from adenomas or polyp cancers by the endoscopist. It is for this reason that all polyps are removed. However, polypectomy increases the risk of perforation and results in a significant cost in processing the samples. Recently it has been suggested that it is possible to differentiate neoplastic from non neoplastic lesions in the colon using skills in polyp surface pattern recognition.
Kudo's pit pattern is an effective way of in-vivo prediction of histology and differentiating neoplastic from non neoplasic polyps. However, it was originally described using vial staining which is cumbersome, time consuming and is not possible to perform outside Japan due to lack of availability and fears of toxicity related to gentian violet. It does however produce excellent results when used for pit pattern recognition. (Hurlstone DP C. S., 2004) It works by irreversibly binding microbial DNA and directly inhibiting cell replication. (Wakelin LPG, 1981).
Gentian violet is not the only way to examine the surface patterns of polyps. Many of the features can be seen with white light endoscopy. (Fu KI, 2004). Furthermore, there is extensive experience with other dies which are commonly used in Western Europe. Indigo carmine dye spray has been performed in studies in Japan, and has proven to be very effective in the assesment of polyp characteristics. It has been used for over 14 years in colonoscopy (Axelrad, 1996). Overall diagnostic accuracy by conventional view, chromoendoscopy and chromoendoscopy with magnification ranged from 68% to 83%, 82% to 92%, and 80% to 96%, respectively. (Axelrad AM, 1996) (Tung SY, 2001) (Eisen GM, 2002) (Su MY, 2004) (Apel D, 2006). It has the advantage over gentian violet that it does not bind to tissues and is therefore very safe. It has been questioned whether widespread applications of the techniques could influence the indications for biopsy sampling during colonoscopy and the indication for mucosectomy (Yasushi Sano, 2005).
When compared to standard colonoscopy, indigo carmine chromoendoscopy, with magnification, has been shown to increase the accuracy for polyp differentiation from 84% to 96% (Fu KI, 2004). High-resolution indigo carmine chromoendoscopy demonstrated a small increase in accuracy over chromoendoscopy without magnification from 81% to 83% . (Hurlstone DP K. M., 2005).
Because of its numerous benefits in lesion detection and assessment of polyps indigo carmine has become a standard part of colonoscopy and is recognised by the British Society of Gastroenterology as an important skill for the practicing endoscopist. It has become standard practice within Portsmouth Hospitals NHS trust when performing colonoscopy. This is a position which is reflected nationally in most large units which participate in the bowel cancer screening programme.
White light endoscopy and chromoendoscopy are not the only methods of examining colonic polyps. Computed virtual colonoscopy, where a video computer processor within the endoscopy equipment enhances the endoscopic picture have become commonly available. There are systems available from all of the main endoscope manufacturers, including narrow band imaging from Olympus and i-scan from Pentax. Fujinon has developed a very effective post processor technology called FICE which helps define the surface pattern of polyps in great detail. This is now a standard feature on all of the endoscopes produced by the company. It has been shown in a limited number of studies to offer a potentially useful alternative to dye spray in predicting in-vivo histology. (J. Pohl, 2008). A prospective randomised multicentre study looked at 764 patients with FICE compared to white light with targeted indigocarmine spray. It found that FICE and indigocarmine were both able to differentiate adenomas from neoplasia. There was a sensitivity in differentiating adenomas from non-neoplastic polyps of 92.7%,with FICE, comparable but not superior to that of indigocarmine (90.4%), with no statistically significant difference between the two techniques observed. (p=0.44.) FICE did not shorten the procedure time. A prospective series looking at FICE in the evaluation of colononic polyps up to 2cm in size by the same team suggested a sensitivity of 89% could be achieved. Unfortunately these studies looked at larger lesions and therefore it is difficult to say whether this could be achieved with polyps \<1cm, where accurate assessment is clearly more difficult. However, it is in the smaller lesions where the greatest gain in terms of a change in management exists. (Pohl J N.-T. M., 2008).
It is generally accepted that further research is needed in this field. If it is possible for endoscopists to differentiate neoplastic from non neoplastic polyps the potential benefits both in terms of safety and histopathology costs would be significant. The current policy of polypectomy or biopsy of all polyps detected during colonoscopy is a very expensive option (£ 80-120) and carries a significant risk of perforation.
Within Portsmouth Hospitals NHS trust it has become standard practice to assess all polyps with FICE and dye spray with indigo carmine prior to removal. This is consistent with current guidelines from the British society of Gastroenterologists and is important both in the detection and assessment of polyps. These techniques are established and their importance in colonoscopy is not under investigation. What is unclear is whether endoscopists are able to differentiate neoplastic from non-neoplastic lesions on a basis of surface pattern recognition accurately enough to be able to change clinical practice.
We aim to assess the impact of surface pattern assessment on the potential management of patients, and whether it has the potential to safely replace the policy of biopsy / polypectomy for pateints with polyps \<10mm in size.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
In vivo diagnosis
Patients undergoing colonoscopy where one or more polyps up to 10mm in size are found.
Observation of surface patterns of polyps
examination of the surface patterns of polyps using FICE and indigo carmine dye spray
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Observation of surface patterns of polyps
examination of the surface patterns of polyps using FICE and indigo carmine dye spray
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Portsmouth Hospitals NHS Trust
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Pradeep Bhandari, MBBS,MD,MRCP
Role: PRINCIPAL_INVESTIGATOR
Consultant gastroenterologist
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Portsmouth Hospitals NHS trust
Portsmouth, Hampshire, United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PHT2009/046
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.