Detection of Atelectasis or Pneumothorax and Resolution With Electrical Impedance Tomography (EIT) in Newborn Infants
NCT ID: NCT04848727
Last Updated: 2022-11-22
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
20 participants
OBSERVATIONAL
2021-08-06
2022-06-07
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Electrical Impedance Tomography for Identification of Optimal Positive End-expiratory Pressure in Newborn Infants
NCT05612256
Triple EIT (Electrical Impedance Tomography)
NCT07247474
Comparison of Computertomography Scan, Electrical Impedance Tomography, and Ultrasound of the Lung in Infants
NCT04989439
Continuous Regional Analysis Device for Neonate Lung
NCT02962505
Electrical Impedance Tomography for Quantification of Pulmonary Edema in Acute Respiratory Distress Syndrome Patients
NCT02870894
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
* TimePeriod 1 (t1): The reference lung air content will be measured once the asymmetric lung disease is identified on chest x-ray.
* TimePeriod 2 (t2): A post-lung disease EIT measurement will be obtained at 6-24 hours later or immediately after therapy (i.e. chest tube placement or needle decompression).
Eligible infants with confirmed asymmetric lung disease (atelectasis or pneumothorax) by radiographic images requiring no respiratory support or on mechanical support or nCPAP therapy of 5-8 cm H20 achieved with a ventilator, an underwater "bubble" system, or a variable-flow device will be enrolled. All of these methods of providing the therapy are done with FDA approved devices currently used in the NICU.
EIT data will be acquired using The LuMon Monitor-Neo, GUI software 1.0.x.x/TIC software 1.6.x.xxx (SenTec, Landquart, Switzerland). The EIT system will be placed at the subject's bedside to collect EIT measurements: Ventilation distribution%, changes in regional aeration in arbitrary units (AU), dependent and non-dependent silent spaces.
A data acquisition cart will also be placed at the subject's bedside to collect hemodynamic and respiratory parameters measurements including: Heart rate (HR), blood pressure (BP), respiratory rate (RR), fraction of inspired oxygen (FiO2), transcutaneous carbon dioxide (TcCO2), and peripheral oxygen saturation (SpO2) via bedside monitoring devices.
The LuMon belts for neonates are disposable single-patient use belts that are adhesive-free and consists of 32 electrodes which are sized to the infant's chest circumference, generally at the 4th - 6th rib. Warmed NeoContactAgent (ingredients: Aqua, Glycerol, Sodium chloride) will be applied to the belt before placing on the infant. The embedded position sensor permits the LuMon System to measure and display the patient's position. The soft and expandable closure band prevents the chest from being constrained by the belt and, consequently, prevents restrictions to breathing and increased work of breathing.
EIT measurements and data will be collected on each timeperiods (t1 and t2) for approximately 15-30 minutes on invasive or non-invasive ventilatory support.
The EIT measurements may be repeated on an eligible participant if a reoccurrence of a confirmed asymmetric lung disease, atelectasis or pneumothorax, is identified on a radiographic image.
EIT is currently not used for patient care management at SMBHWN. EIT's use for patient care management is purely experimental. EIT, when used solely for physiologic data collection, its use is not subject to 21 CFR 50, 21 CFR 56, or 21 CFR 812. Data collection via EIT will occur when the subject is in a quiet, sleeping state, and can be accomplished in a convenient time period when care givers or parents are not interacting with the subject.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Atelectasis or Pneumothorax
Infants with asymmetric lung disease (i.e. atelectasis or pneumothorax) confirmed by chest radiograph
Detecting asymmetric lung disease like atelectasis or pneumothorax with electrical impedance tomography (EIT)
The EIT system will be placed at the subject's bedside to collect EIT measurements: Ventilation distribution%, changes in regional aeration in arbitrary units (AU), dependent and non-dependent silent spaces. A data acquisition cart will also be placed at the subject's bedside to collect hemodynamic and respiratory parameters measurements including: Heart rate (HR), blood pressure (BP), respiratory rate (RR), fraction of inspired oxygen (FiO2), transcutaneous carbon dioxide (TcCO2), and peripheral oxygen saturation (SpO2) via bedside monitoring devices.
The LuMon belts for neonates are disposable single-patient use belts that are adhesive-free. EIT measurements and data will be collected on each timeperiods (t1 and t2) for approximately 15-30 minutes on invasive or non-invasive ventilatory support.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Detecting asymmetric lung disease like atelectasis or pneumothorax with electrical impedance tomography (EIT)
The EIT system will be placed at the subject's bedside to collect EIT measurements: Ventilation distribution%, changes in regional aeration in arbitrary units (AU), dependent and non-dependent silent spaces. A data acquisition cart will also be placed at the subject's bedside to collect hemodynamic and respiratory parameters measurements including: Heart rate (HR), blood pressure (BP), respiratory rate (RR), fraction of inspired oxygen (FiO2), transcutaneous carbon dioxide (TcCO2), and peripheral oxygen saturation (SpO2) via bedside monitoring devices.
The LuMon belts for neonates are disposable single-patient use belts that are adhesive-free. EIT measurements and data will be collected on each timeperiods (t1 and t2) for approximately 15-30 minutes on invasive or non-invasive ventilatory support.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Informed consent obtained
3. Atelectasis confirmed on CXR
4. Pneumothorax confirmed on CXR
Exclusion Criteria
2. Infants with known congenital anomalies
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Sharp HealthCare
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Anup Katheria, M.D.
Director Neonatal Research Institute
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Anup C Katheria, MD
Role: PRINCIPAL_INVESTIGATOR
Sharp HealthCare
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sharp Mary Birch Hospital for Women & Newborns
San Diego, California, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Costa EL, Borges JB, Melo A, Suarez-Sipmann F, Toufen C Jr, Bohm SH, Amato MB. Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography. Intensive Care Med. 2009 Jun;35(6):1132-7. doi: 10.1007/s00134-009-1447-y. Epub 2009 Mar 3.
Miedema M, McCall KE, Perkins EJ, Sourial M, Bohm SH, Waldmann A, van Kaam AH, Tingay DG. First Real-Time Visualization of a Spontaneous Pneumothorax Developing in a Preterm Lamb Using Electrical Impedance Tomography. Am J Respir Crit Care Med. 2016 Jul 1;194(1):116-8. doi: 10.1164/rccm.201602-0292LE. No abstract available.
Rahtu M, Frerichs I, Waldmann AD, Strodthoff C, Becher T, Bayford R, Kallio M. Early Recognition of Pneumothorax in Neonatal Respiratory Distress Syndrome with Electrical Impedance Tomography. Am J Respir Crit Care Med. 2019 Oct 15;200(8):1060-1061. doi: 10.1164/rccm.201810-1999IM. No abstract available.
Kallio M, Rahtu M, van Kaam AH, Bayford R, Rimensberger PC, Frerichs I. Electrical impedance tomography reveals pathophysiology of neonatal pneumothorax during NAVA. Clin Case Rep. 2020 May 24;8(8):1574-1578. doi: 10.1002/ccr3.2944. eCollection 2020 Aug.
Related Links
Access external resources that provide additional context or updates about the study.
Design/patents related to the Lumon System
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
DePIct
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.