Test-retest Reliability of Two Measurements of the Visual System
NCT ID: NCT03242421
Last Updated: 2020-02-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
21 participants
OBSERVATIONAL
2017-08-07
2017-09-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
One such evaluation method is reliability. A reliable test is one that will give the same result when repeated on multiple occasions (i.e. test-retest reliability) or by different people (inter-rater reliability). An unreliable test gives widely varying results when repeated, which would make changes in a patient's test results difficult to interpret. Therefore, this study aims to determine the test-retest reliability of seven binocular vision tests across two independent measurements. The investigators will measure 20 healthy people ages 18 to 35 years for each of these tests on two separate occasions, one week apart. Since these tests have been in use for many years, we are expecting the two measurements to be within acceptable range of each other.
The tests being investigated measure: 3D vision (i.e. gross stereoscopic acuity), uniform movement of the eyes (i.e. "motor punctum proximum"), ability of the eyes to adapt to a target moving towards and/or away from the eyes (i.e. binocular fusion with convergence and divergence), quick movements of the eyes (i.e. saccadic movements), natural alignment of the eyes (i.e. anatomic oculomotor deviation), and double vision as a target is moved towards the eyes (i.e. convergence fusional proximum).
The results of each test will be analyzed individually. If the tests are perfectly reliable, we would expect the results of the first test to equal the results of the second test for each participant. To examine the test-retest reliability the difference between the first and second test for each individual and across all individuals' scores summed together will be assessed.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of Different Color Vision Tests in Children
NCT02464241
A More Engaging Visual Field Test to Increase Use and Reliability in Pediatrics
NCT02157025
Randomized Controlled Trial on Visual Field Training
NCT01669031
Subjective Image Quality in Stereoscopic Image Modifications
NCT01624415
Study of Eye Movement Testing and Therapy
NCT00472485
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
One such method of evaluation is reliability. A reliable test is one that will provide the same results when repeated on multiple occasions (i.e. test-retest reliability), by different people (i.e. inter-rater reliability), or the same person (i.e. intra-rater reliability). An unreliable test yields widely varying results when repeated, which would make changes in a patient's test results difficult to interpret. In this study, test-retest reliability will be estimated using a single clinician (equivalent to intra-rater reliability) as it examines the degree to which a test is able to produce consistent results or whether it is dependent on the situation or the state of the individual being tested (Rousson, Gasser, \& Seifert, 2002). In future studies, inter-rater reliability will be examined which is largely dependent on and concerned with adequate training of raters as opposed to the properties of the test itself.
Furthermore, for health measures - such as the binocular vision tests - to be useful in clinically guiding patient management, they must be valid and sensitive to the system of interest (i.e. visual system). We are currently unable to quantify the validity of these binocular vision tests as this domain lacks a "gold-standard" (Hachana et al., 2013), thus, test-retest reliability must be determined first (Broglio et al., 2007). Therefore, this study aims to determine the test-retest reliability of seven binocular vision tests across two independent measurements. Twenty healthy participants aged 18 to 35 years will be measured on two separate occasions, one week apart. Since these tests have been in use for many decades, it is hypothesized that the two measurements will be within acceptable range of each other.
The binocular vision tests undergoing examination differ from optometry tests in that they use more advanced equipment which can measure very small deviations in several domains of the visual system. These seven binocular vision tests measure various elements of the visual system and will be described in detail below:
Gross stereoscopic acuity: (range 0-15 arc seconds) Our binocular vision allows us to see in three dimensions (3D), or more simply, to see depth. In this test, seated participants wearing 3D glasses are shown images. Inability to see depth or 3D will cause images to appear as points instead of objects. The objects are presented in different stages, with each stage requiring them to discriminate different levels of depth perception. The test is scored in optical units, with a range of 0 to 15 arc-seconds. The maximum score corresponds to the level where the last object was identified.
Near point of convergence and near point of convergence - break: (cm) When an object is moving towards our eyes, they symmetrically converge in order to maintain focus. However, there is a point at which our eyes no longer symmetrically converge (point of convergence). This test measures the distance (cm) between the bridge of the nose and point of convergence in seated participants as an object is moved closer to the head.
Positive fusional vergence: (diopters, prism convergence units) This test measures how well someone can adapt to challenges in focusing light on the retina. There are two almost identical tests. One test occurs with an object placed at 3m from the seated participant, and the other with an object at 30cm from the seated participant. Light from an image is passed through a prism. This is analogous to moving the image further away from the body. In response, the eyes must diverge (separate) to focus on the object, just as they would if the image actually moved away from the body. Different prisms are used to create increasing challenges. The score for these tests is simply the maximum amount of prism convergence (dioptres, noted on the prism, as one would note diopters on eye glasses) that the seated participant can accommodate at 3m and at 30cm.
Negative fusional vergence: (diopters, prism convergence units) This is the same test as (3), except that the prisms diverge the light and the participant has to converge their eyes to maintain focus. The score for these tests is simply the maximum amount of prism divergence (diopters, noted on the prism, as one would note diopters on glasses) that the seated participant can accommodate at 3m, and at 30cm.
Saccadic movements or oculomotor capacity: (Score = bad, medium, good) A light appears on the screen and the participant move their eyes to fix on the object. While they eyes adjust, they will temporarily cover small distances until they achieve a fixed focus. These are called saccadic movements. Lights appear and disappear, in different locations on the screen, at a rate of 100 per minute, lasting 2 minutes. The test result is scored by the evaluator based on a global impression over the entire 2 minutes, with 3 separate sub scores on an ordinal scale for quality (bad, medium, good), for synchronization (bad, medium, good) and saccadic correction (many corrections, few corrections, no corrections). The three sub scores are combined into an overall score according to our industry partner's (Apexk) proprietary algorithm.
Anatomic oculomotor deviation: (diopters, prism convergence units) This test measures the eyes' natural deviation (heterophoria) and also allows the detection of strabismus. In strabismus, anatomic deviation is evident and the person's dominant eye is looking at you, but the "lazy/deviated" eye is not. In heterophoria anatomic deviation is not visible to the naked eye and the deviation has to be triggered by covering in sequence, one eye at a time, to trigger the deviation. There are two identical tests: one occurs with an object placed at 3m from the seated participant (far vision), and the other with an object at 30cm from the seated participant (near vision). In this test, seated participants focus on an object. These movements can be seen by the clinician. The clinician covers/uncovers eyes to trigger movements and uses a prism to cancel the movement. The prism that achieves this cancellation is the measure of anatomic deviation. The rating of the prism that achieves this cancellation is considered the score for this test, with one score for the object placed at 3m and another score for the object placed at 30cm. Participants with strabismus are excluded in our study because strabismus is a contra-indication to post-concussion visual training, which is part of our larger study and thus, patients with strabismus do not represent our target population.
Convergence fusional proximum: (diopters, prism convergence units) This test is similar to (2) above. When an object is moving closer to our head, the eyes symmetrically converge. When the object is moved beyond the participant's ability to converge, the participant will start to see two images (double vision). This test measures the distance between the bridge of the nose and point where double vision (cm) occurs in seated participants as an object is moved closer.
In addition, demographic information relevant to our study will be collected in order to appropriately describe the population and explore if these factors modify the test-retest correlations. Variables such as age, sex, highest level of education achieved (i.e. secondary school, CEGEP, university), the use of corrective lenses for vision problems, occupation, and any relevant past medical history (i.e. migraines, vision problems, medication, etc) will be included.
The main objective of this study is to evaluate the agreement and consistency between measurements of the visual system taken at two different times to determine the test-retest reliability of the seven binocular vision tests. To do so, the results of each test will be analyzed individually. If the tests are perfectly reliable, it is expected that the value of the first test is equal to the value of the second test for each participant across the range of values for all individuals. Reliability will be assessed using the intra-class coefficient (ICC) which measures the between-group variance divided by the total variance (sum of between- and within-group variance). The difference between the first and second test for each participant is called the within-group (each participant represents a group) variance. The difference across individuals is the between-group variance. If the within-group variance is 0 (first and second measures are identical), then the ICC = 1 (between-group variance / (between-group variance + 0)). In addition to the ICC, limits of agreement will be estimated using the paired data and illustrated via Bland-Altman plot (Bland \& Altman, 1986).
As the binocular vision tests we are examining have applicability in many health conditions (e.g. concussion, Alzheimer's, etc.), this study has the potential to contribute to the improved management of symptoms related to the visual system.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
OTHER
PROSPECTIVE
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Provide informed consent to participate in study
Exclusion Criteria
* History of migraine or known neurological disorders
* Use myorelaxants or medications for depression, anxiety, or other psychological condition
18 Years
35 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
McGill University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ian Shrier
Senior Investigator, Centre for Clinical Epidemiology, Lady Davis Institute; Associate Professor, Department of Family Medicine, McGill University
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ian Shrier, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
McGill University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
McGill University
Montreal, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Horwood A, Toor S. Clinical test responses to different orthoptic exercise regimes in typical young adults. Ophthalmic Physiol Opt. 2014 Mar;34(2):250-62. doi: 10.1111/opo.12109. Epub 2014 Jan 29.
Hachana Y, Chaabene H, Nabli MA, Attia A, Moualhi J, Farhat N, Elloumi M. Test-retest reliability, criterion-related validity, and minimal detectable change of the Illinois agility test in male team sport athletes. J Strength Cond Res. 2013 Oct;27(10):2752-9. doi: 10.1519/JSC.0b013e3182890ac3.
Broglio SP, Ferrara MS, Macciocchi SN, Baumgartner TA, Elliott R. Test-retest reliability of computerized concussion assessment programs. J Athl Train. 2007 Oct-Dec;42(4):509-14.
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986 Feb 8;1(8476):307-10.
Rousson V, Gasser T, Seifert B. Assessing intrarater, interrater and test-retest reliability of continuous measurements. Stat Med. 2002 Nov 30;21(22):3431-46. doi: 10.1002/sim.1253.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IT08159
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.