Microaspiration and Endotracheal Tubes

NCT ID: NCT07017205

Last Updated: 2025-12-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

72 participants

Study Classification

INTERVENTIONAL

Study Start Date

2026-02-01

Study Completion Date

2026-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this clinical trial is to learn if a new method for managing breathing tube pressure is better at preventing fluid from leaking into patients' lungs during surgery. It will also check if it causes fewer side effects like a sore throat.

The main questions it aims to answer are:

Does using a continuous pressure controller reduce fluid leakage past the breathing tube cuff compared to the standard manual method? Does the continuous pressure controller lead to fewer and less severe sore throats and voice changes after surgery?

Researchers will compare two groups:

Group 1: Patients whose breathing tube cuff pressure is managed with a continuous automatic controller.

Group 2: Patients whose breathing tube cuff pressure is managed with the standard manual method.

Participants will:

Be randomly assigned to one of the two groups before their surgery. Receive a small, safe amount of blue dye in their mouth during the procedure to help measure leakage.

Have two small secretion samples collected from their breathing tube during surgery.

Be asked about sore throat and voice changes at 1, 2, 3, and 24 hours after the breathing tube is removed.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

1. The Clinical Challenge: Microaspiration and the Breathing Tube

Endotracheal intubation is a life-saving procedure, but it inherently bypasses the body's natural defenses against lung infection. A critical, yet often overlooked, problem is microaspiration. This is the silent leakage of small amounts of oropharyngeal secretions past the cuff of the breathing tube and into the lower airways and lungs. This phenomenon is a primary contributor to the development of Ventilator-Associated Pneumonia (VAP), a serious complication that increases patient morbidity, mortality, and healthcare costs.

The cuff's primary role is to create a seal within the trachea. However, conventional cylindrical cuffs can form folds or channels when inflated, creating a direct pathway for secretions to leak through. Furthermore, maintaining the correct cuff pressure (recommended 25-30 cmH₂O) is challenging; pressure can fluctuate due to patient movement, changes in anesthesia gas volume, and surgical positioning.
2. Technological Innovations and the Evidence Gap

To address these issues, manufacturers have developed advanced endotracheal tubes. This study focuses on the TaperGuard™ Evac tube (Covidien/Medtronic), which features a uniquely shaped tapered cuff. This design is intended to inflate more uniformly against the tracheal wall, theoretically reducing the formation of leakage channels compared to traditional cylindrical cuffs.

Concurrently, technology for pressure management has evolved. While the current standard of care involves intermittent manual checks with a manometer, automated cuff pressure controllers (like the Pressure Easy® device) have been introduced. These devices continuously monitor and adjust the pressure, maintaining it within a pre-set target range throughout the entire procedure without manual intervention.

While laboratory (bench-top) studies strongly suggest that tapered cuffs are superior at preventing fluid leakage, and some early clinical studies are promising, there is a lack of robust, in-vivo evidence from a controlled surgical setting. This study aims to fill that gap by directly testing the combined effect of the advanced tube design with two different levels of pressure management sophistication.
3. The Study's Core Investigation: A Two-Factor Comparison

This trial is not just testing a new device, but rather investigating a clinical management strategy. The central question is: Does moving from a manual, intermittent pressure management protocol to a continuous, automated one provide a significant clinical benefit when using a modern, tapered-cuff endotracheal tube?

To answer this, we are employing a rigorous model to objectively quantify microaspiration:

The Blue Dye Model: A small, safe volume of blue dye is instilled into the patient's oropharynx above the cuff after intubation. The presence or absence of this dye in tracheal aspirate samples, collected later from below the cuff, serves as an objective, binary measure (Yes/No) of whether leakage has occurred.
4. Broader Impact and Secondary Patient-Centered Outcomes

Beyond the primary goal of preventing pneumonia, the study also investigates patient comfort and safety post-operatively. Damage to the tracheal mucosa from improper cuff pressure or physical irritation from the tube can lead to:

Post-extubation sore throat: A common and uncomfortable complaint.

Post-extubation dysphonia: Hoarseness or voice changes resulting from vocal cord irritation.

By ensuring more stable and optimal cuff pressure, the continuous controller may mitigate these issues. We will track these outcomes using standardized, validated scales (a Numeric Rating Scale for pain and the GRBAS scale for voice quality) to determine if the intervention leads to a tangible improvement in the patient's immediate recovery experience.
5. Methodological Rigor

To ensure the results are reliable and unbiased, the study employs key methodological safeguards:

Randomization: Patients are randomly assigned to a study group using a computer-generated sequence to ensure groups are comparable.

Partial Blinding: While the clinical team at the bedside cannot be blinded to the monitoring device, the laboratory analysis of the tracheal secretion samples is performed by personnel who are completely unaware of which group the sample came from. This prevents bias in determining the primary outcome.

In summary, this study seeks to provide high-quality evidence to guide clinical practice in operating rooms, determining if an investment in automated pressure control technology yields measurable benefits in patient safety and comfort when using state-of-the-art endotracheal tubes.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Endotracheal Tube Cuff Microaspiration Endotracheal Tube Cuff Pressure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

SCREENING

Blinding Strategy

DOUBLE

Participants Investigators
In addition to the participants, both the investigator responsible for patient randomization and the evaluator analyzing the samples for microaspiration will be blinded to group allocation. This double-masking approach is intended to minimize bias in both the allocation process and the outcome assessment.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Conventional Cuff Pressure Control Group

Patients will be intubated by experienced anesthesiologists using a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system. Cuff inflation will be performed using the standard method commonly employed in clinical practice (passive recoil of syringe plunger).

Group Type ACTIVE_COMPARATOR

Application of oropharyngeal dye and tracheal aspirate collection

Intervention Type DEVICE

After intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP \>65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis.

Continuous Cuff Pressure Control Group

The intervention group will receive a TaperGuard Evac tube (Covidien) with tapered cuff and subglottic suction system, plus continuous cuff pressure monitoring using the Pressure Easy® device (Medtronic) to maintain 25-30 cmH₂O.

Group Type EXPERIMENTAL

Application of oropharyngeal dye and tracheal aspirate collection

Intervention Type DEVICE

After intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP \>65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Application of oropharyngeal dye and tracheal aspirate collection

After intubation, 2 mL of blue dye will be applied to the oropharyngeal mucosa. Once hemodynamically stable (MAP \>65 mmHg), the first tracheal aspirate will be collected within 10 minutes by a blinded investigator for analysis.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Adult patients (\>18 years old) scheduled for surgery lasting at least one hour.
* ASA I-III classification.
* Signed informed consent.

Exclusion Criteria

* Pre-existing airway pathology (e.g., tracheomalacia, granulomas, stenosis, tumors).
* Anticipated difficult intubation (Macocha Score \> 3 points).
* Selective lung ventilation / one-lung ventilation.
* Current participation in another clinical trial.

Elimination Criteria:

* Accidental extubation.
* Cardiorespiratory arrest or death.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Argentinian Intensive Care Society

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Gustavo Plotnikow

Head of Physical and Respiratory Care Department, ICU

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hospital Britanico de Buenos Aires

CABA, Buenos Aires, Argentina

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Argentina

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Gustavo A Plotnikow, BPT; BCs ICU; PhD(c)

Role: CONTACT

+5491164543771

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Gustavo A Plotnikow

Role: primary

+5491164543771

References

Explore related publications, articles, or registry entries linked to this study.

Dullenkopf A, Gerber A, Weiss M. Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube. Intensive Care Med. 2003 Oct;29(10):1849-53. doi: 10.1007/s00134-003-1933-6. Epub 2003 Aug 16.

Reference Type BACKGROUND
PMID: 12923620 (View on PubMed)

Lorente L, Lecuona M, Jimenez A, Lorenzo L, Roca I, Cabrera J, Llanos C, Mora ML. Continuous endotracheal tube cuff pressure control system protects against ventilator-associated pneumonia. Crit Care. 2014 Apr 21;18(2):R77. doi: 10.1186/cc13837.

Reference Type BACKGROUND
PMID: 24751286 (View on PubMed)

Blot SI, Poelaert J, Kollef M. How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients. BMC Infect Dis. 2014 Nov 28;14:119. doi: 10.1186/1471-2334-14-119.

Reference Type BACKGROUND
PMID: 25430629 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PRIISABA15678

Identifier Type: -

Identifier Source: org_study_id