Effect of Different Apex Locators on Postoperative Pain in Endodontic Retreatment of Single-Rooted Teeth: Prospective Randomized Clinical Study
NCT ID: NCT06964490
Last Updated: 2025-05-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
PHASE4
120 participants
INTERVENTIONAL
2025-05-01
2025-08-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
A key factor in the success of both primary endodontic treatment and retreatment is the accurate determination of working length (WL), which dictates the apical extent of canal instrumentation and obturation \[5\]. Inadequate WL may result in over-instrumentation, leading to periapical irritation and postoperative pain \[6\]. WL is generally defined as the distance from a coronal reference point to the location where canal cleaning, shaping, and filling should ideally terminate, often coinciding with the apical constriction, and occasionally with the cementodentinal junction, where pulpal and periodontal tissues transition \[5\].
Although periapical radiographs are still commonly used for WL determination, they do not always provide definitive results due to certain limitations. Factors such as improper film placement, angular distortion, image magnification and distortion, patient exposure to ionizing radiation, and the superimposition of anatomical structures can compromise the accuracy of measurements \[7\]. As a result, electronic apex locators (EALs) have gained prominence as a dependable and objective tool for determining WL, offering real-time measurements less influenced by operator variability or anatomical distortions \[6\].
The initial generations of electronic apex locators (EALs) exhibited inconsistent readings and limited accuracy, particularly in the presence of irrigation solutions or tissue fluids. However, recent advancements have significantly enhanced the reliability and clinical performance of EALs. Modern EALs, such as the ProPex Pixi (Dentsply, Switzerland) and Root ZX (J. Morita, Japan) apex locators, utilize multiple-frequency impedance measurements to detect changes as the file approaches the minor apical foramen \[8\]. These devices are equipped with microprocessors that analyze real-time impedance variations, allowing for dynamic and accurate assessment of canal length during instrumentation. Thanks to these technological enhancements, contemporary EALs can precisely identify the apical constriction, even under challenging clinical conditions \[9\]. Recent studies have demonstrated that modern devices can achieve up to 90% accuracy in WL determination, making them indispensable tools in both primary and secondary endodontic procedures \[9, 10\]. Raypex (Raypex 6, VDW GmbH, Munich, Germany) is another widely used electronic apex locator (EAL). Aydın et al. \[11\] demonstrated that Raypex 6 showed success rates of 85% and 95% within ±0.5 mm and ±1 mm, respectively, in teeth with mature apices. Although apex locators function with the same principle, the areas detected by different devices may differ. These variations in apical measurements among different EALs may not only affect treatment accuracy but could also influence the extent of postoperative pain experienced by the patient.
Postoperative pain is a significant concern in endodontics, with its incidence ranging from 3% to 58% \[12\]. Irritation of periradicular tissues during root canal treatment induces an acute inflammatory response, leading to the release of chemical mediators and changes in local pressure and tissue adaptation \[13\]. Accurate WL determination plays a critical role in minimizing postoperative pain \[14\]. Although the use of electronic EALs in WL determination during root canal treatment has been widely accepted, there are only a limited number of clinical studies investigating their effect on postoperative pain. Recent studies have explored the clinical performance and accuracy of different EALs; however, their focus was primarily on measurement precision rather than postoperative outcomes like pain or patient comfort \[7, 15\].
Despite the increasing use of EALs in endodontic procedures, there is currently no clinical study that examines the impact of using different apex locator devices on postoperative pain in the nonsurgical endodontic retreatment. Given the added complexity of retreatment cases, such as the need to remove previous obturation materials and the potential for greater periapical irritation, this represents a significant gap in the literature. The primary aim of this randomized clinical study is to evaluate and compare the effect of WL determination using different apex locator
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effectiveness of Different Obturation Techniques
NCT06226740
Effect of Different Apical Actions on Local Inflammatory Mediators and Pain
NCT06760312
Treatment Durations for Endodontic Procedures
NCT07304869
The Effects of EndoActivator on Postoperative Pain and Root Canal Treatment Success
NCT06339905
The Effect of Apical Patency on Postoperative Pain Following Root Canal Treatment
NCT07233590
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ProPex Pixi Apex Locator
determination of working length
Compare the effect of WL determination using different apex locator devices (ProPex Pixi, Root ZX, and Raypex 6) on the incidence and intensity of postoperative pain following endodontic retreatment in single-rooted teeth
Root ZX Apex Locator
determination of working length
Compare the effect of WL determination using different apex locator devices (ProPex Pixi, Root ZX, and Raypex 6) on the incidence and intensity of postoperative pain following endodontic retreatment in single-rooted teeth
Raypex 6 Apex Locator
determination of working length
Compare the effect of WL determination using different apex locator devices (ProPex Pixi, Root ZX, and Raypex 6) on the incidence and intensity of postoperative pain following endodontic retreatment in single-rooted teeth
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
determination of working length
Compare the effect of WL determination using different apex locator devices (ProPex Pixi, Root ZX, and Raypex 6) on the incidence and intensity of postoperative pain following endodontic retreatment in single-rooted teeth
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
60 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ipek Eraslan Akyuz
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ipek Eraslan Akyuz
dentist
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2025/3
Identifier Type: -
Identifier Source: org_study_id
More Related Trials