WatchPAT SpO2 Validation Study

NCT ID: NCT06947447

Last Updated: 2025-08-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

24 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-04-21

Study Completion Date

2025-05-02

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Validate the SpO2 accuracy of the WatchPAT compared to arterial blood CO-Oximetry

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The goal of this comparative, single-center, non-randomized study is to validate the SpO2 accuracy performance of the WatchPAT SpO2 sensor over the range of 70-100% SaO2 during non-motion conditions assessed by CO-Oximetry in 24 healthy male and female participants of any race, ranging in pigmentation from light to dark, aged 18-50 years old. The participants will have an arterial catheter placed in the radial artery to allow for simultaneous blood samples during stable plateaus of induced hypoxic levels, while an investigational device will be placed on the fingers of both hands.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

WatchPAT SpO2

Simultaneous data collection will be set up for the reference(s) and the device under test. The participants will have an arterial catheter placed in the radial artery to allow for simultaneous blood samples during stable plateaus of induced hypoxic levels. The WatchPAT will be placed on the finger(s) of both hands following the instructions for use.

Each participant test is expected to take approximately 1.5 to 2 hours.

No intervention

Intervention Type DEVICE

Device

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

No intervention

Device

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Participant must have the ability to understand and provide written informed consent.
* Participant is adult 18-50 years of age.
* Participant must be willing and able to comply with study procedures and duration.
* Participant is a non-smoker or who has not smoked within 2 days prior to the study.
* Male or female of any race.

Exclusion Criteria

* Participant is considered as being morbidly obese (defined as BMI \>39.5)
* Compromised circulation (i.e., Raynaud's Syndrome), injury, or physical malformation of fingers, toes, hands, ears or forehead/skull or other sensor sites which would limit the ability to test sites needed for the study. Tattoos in the optical path which would limit the ability to test sites needed for the study. (Note: Certain malformations may still allow participants to participate if the condition is noted and would not affect the sites utilized.)
* Females who are pregnant, who are trying to get pregnant, (confirmed by positive urine pregnancy test unless the participant is known to be not of child-bearing potential)
* Participants who have smoked in the last 2 days or participants who have refrained, for at least 48 hours, with COHb levels \>3% as assessed with a Masimo Radical 7 (Rainbow)
* Participants with known respiratory conditions such as: (self-reported)

* uncontrolled / severe asthma,
* flu,
* pneumonia / bronchitis,
* shortness of breath / respiratory distress,
* unresolved respiratory or lung surgery,
* emphysema, COPD, lung disease
* Recent COVID with hospitalization
* Participants with self-reported heart or cardiovascular conditions such as: (self-reported, except for blood pressure and ECG review)

* high blood pressure: systolic \>140 mmHg or diastolic \>90 mmHg on 3 consecutive readings (reviewed during health screen)
* have had cardiovascular surgery, except successful minor surgery without clinical symptoms (i.e., PFO, PDA)
* chest pain (angina)
* heart rhythms other than a normal sinus rhythm or with respiratory sinus arrhythmia (reviewed during health screen)
* previous heart attack
* blocked artery
* unexplained shortness of breath
* congestive heart failure (CHF)
* history of stroke
* transient ischemic attack
* carotid artery disease
* myocardial ischemia
* myocardial infarction
* cardiomyopathy
* implantable active medical device such as pacemaker or automatic defibrillator
* Self-reported health conditions as identified in the Health Assessment Form

* diabetes,
* uncontrolled thyroid disease,
* kidney disease / chronic renal impairment,
* history of seizures (except childhood febrile seizures),
* epilepsy,
* history of unexplained syncope,
* recent history of frequent migraine headaches,
* recent symptomatic head injury (within the last 2 months),
* Cancer requiring chemotherapy, radiation, or current treatment.
* Participants with known clotting disorders (self-reported)

* history of bleeding disorders or personal history of prolonged bleeding from injury
* history of blood clots
* hemophilia
* current use of blood thinner: prescription or daily use of aspirin
* Sickle Cell Trait or Disease
* Participants with severe contact allergies to standard adhesives, latex, silicone or other materials found in pulse oximetry sensors, ECG electrodes, respiration monitor electrodes or other medical sensors (self-reported)
* Participants with severe allergies to iodine (only applicable if iodine is used)
* Participants with severe allergies to lidocaine (or similar pharmacological agents, e.g. Novocaine),
* Failure of the Perfusion Index Ulnar/Ulnar+Radial Ratio test (Ratio \<0.4)
* Unwillingness or inability to remove colored nail polish or non-clear artificial nails from test digits.
* Surgical hardware in pathway of Device Under Test
* Other known health conditions should be considered upon disclosure in health assessment form.
Minimum Eligible Age

18 Years

Maximum Eligible Age

50 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Element Materials Technology

INDUSTRY

Sponsor Role collaborator

Itamar-Medical, Israel

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Element Materials Technology

Louisville, Colorado, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PR# 2024-598

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Postoperative Extubation in Hypoxemic Patients
NCT06688487 NOT_YET_RECRUITING NA