Clinical Assessment Of Inlay Retained Bridge Designs (Tub Shaped And Inlay Shaped) In Missing Posterior Teeth Cases.

NCT ID: NCT03715842

Last Updated: 2018-10-23

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

7 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-03-11

Study Completion Date

2020-04-11

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The interest in partial coverage retainers such as inlays and onlays have increased drastically because these restorations are able to provide a more conservative option requiring minimal tissue removal thus preserving healthy tooth structure to a maximum extent.

If patient rejects an implant treatment and enough sound tooth structure is available it would be desirable to restore a missing tooth with Inlay-Retained Fixed Partial Denture instead of full coverage retained one .

The use of all-ceramic materials for inlays and onlays in restorative dentistry is becoming more popular , the proper selection of restorative materials, careful preparation design and adequate adhesion between tooth/restorative material interfaces considered important factor to prevent failures .

Zirconia was introduced into dentistry in the 1990s.The high initial strength and fracture toughness of zirconia results from a physical property of partially stabilized zirconia known as transformation toughening. On the other hand, its white color, similar to the color of natural teeth and its ability to transmit light makes it useful in aesthetically important areas .

Inlay Fixed Partial Denture restoration may have increased the risk of fracture due to the relative small size of restorations compared to the complete coverage restoration. An unfavorable distribution of stresses between the ceramic inlay and tooth structure may result in marginal deterioration around the inlay or its failure.

The direction of forces on the occlusal surface of Inlay Fixed Partial Denture may lead to the phenomenon of submargination, ceramic fracture, wear at interface and postoperative hypersensitivity which remain a problem that require further investigation. One of the most important factors in the success and longevity of a restoration is to have an accurate marginal fit. Ideally, the cemented restoration should precisely meet the finish line of the prepared tooth. In reality, clinical perfection is challenging to achieve and to verify.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The tub-shaped inlay preparation design this consists of an occlusal proximal reduction featuring a 3.5-4 mm width bucco-lingually, 3-3.5mm depth occluso-gingivally and 7-7.5 mm length mesio distally for molars and 2.3-2.8mm width buccolingually, 3-3.5 mm depth occluso gingivally and 3.5-4mm length mesiodistally for premolars. when necessary, superficial extensions may also be made on the preparations so that the occlusal fossa included in the preparation area and then the susceptibility for plaque accumulation will be diminished.

Participant timeline

The visits will be designated as follows:

Visit 1: one week after allocation, preoperative records, face-to-face adherence reminder session, clinical examination, radiographic examination, intraoral photography and primary impressions for diagnostic cast construction .

Visit 2: one week after the first visit, teeth preparations, secondary impression and temporization .

Visit 3: one week after the second visit, try in for the restoration will be done.

Visit 4: one week after the try in, final cementation of the restoration.(GC resin cement) Visit 5: follow up after twelve months from the cementation visit.

The aim of the study is to assess the fracture resistance of two inlay retained bridge designs (tub shaped and inlay shaped) in missing posterior teeth cases. Based on previous papers by Ohlmann et al., 2008 7 and İzgi et al.,2011 4 indicate that the failure rate among controls is 52%. If the true failure rate for experimental subjects is 99%, we will need to study 12 in each group to be able to reject the null hypothesis that the failure rates for experimental and control subjects are equal with probability (power) 0.8. The Type I error probability associated with this test of this null hypothesis is 0.05. We will use an uncorrected chi-squared statistic to evaluate this null hypothesis. This number is to be increased to 15 in each group (25% more than the calculated) to compensate for possible losses during follow up. The sample size was calculated by PS: Power and Sample Size Calculation software Version 3.1.2 (Vanderbilt University, Nashville, Tennessee, USA).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Missing Tooth

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Tub shaped design

The tub-shaped preparation design this consists of an occlusal proximal reduction featuring a 3.5-4 mm width bucco-lingually, 3-3.5mm depth occluso-gingivally and 7-7.5 mm length mesio distally for molars and 2.3-2.8mm width buccolingually, 3-3.5 mm depth occluso gingivally and 3.5-4mm length mesiodistally for premolars. when necessary, superficial extensions may also be made on the preparations so that the occlusal fossa included in the preparation area and then the susceptibility for plaque accumulation will be diminished.

Group Type EXPERIMENTAL

Tub shaped design

Intervention Type OTHER

The tub-shaped inlay preparation design this consists of an occlusal proximal reduction featuring a 3.5-4 mm width bucco-lingually, 3-3.5mm depth occluso-gingivally and 7-7.5 mm length mesio distally for molars and 2.3-2.8mm width buccolingually, 3-3.5 mm depth occluso gingivally and 3.5-4mm length mesiodistally for premolars. when necessary, superficial extensions may also be made on the preparations so that the occlusal fossa included in the preparation area and then the susceptibility for plaque accumulation will be diminished.

Inlay shaped design

The occlusal inlay had a preparation depth that allowed a thickness of 2.0 mm for the ceramic. The occlusal preparation was 4 mm wide and extended 4 or 6 mm mesio-distally for the premolar or molar models, respectively. The proximal box was 1 mm wide and had approximately 5˚ divergence, extending 2 mm apical to the isthmus floor . The preparations corresponded to a proximal connector area of 3 mm × 3 mm for molars and premolars.

Group Type ACTIVE_COMPARATOR

Inlay shaped design

Intervention Type OTHER

The occlusal inlay had a preparation depth that allowed a thickness of 2.0 mm for the ceramic. The occlusal preparation was 4 mm wide and extended 4 or 6 mm mesio-distally for the premolar or molar models, respectively. The proximal box was 1 mm wide and had approximately 5˚ divergence, extending 2 mm apical to the isthmus floor . The preparations corresponded to a proximal connector area of 3 mm × 3 mm for molars and premolars.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tub shaped design

The tub-shaped inlay preparation design this consists of an occlusal proximal reduction featuring a 3.5-4 mm width bucco-lingually, 3-3.5mm depth occluso-gingivally and 7-7.5 mm length mesio distally for molars and 2.3-2.8mm width buccolingually, 3-3.5 mm depth occluso gingivally and 3.5-4mm length mesiodistally for premolars. when necessary, superficial extensions may also be made on the preparations so that the occlusal fossa included in the preparation area and then the susceptibility for plaque accumulation will be diminished.

Intervention Type OTHER

Inlay shaped design

The occlusal inlay had a preparation depth that allowed a thickness of 2.0 mm for the ceramic. The occlusal preparation was 4 mm wide and extended 4 or 6 mm mesio-distally for the premolar or molar models, respectively. The proximal box was 1 mm wide and had approximately 5˚ divergence, extending 2 mm apical to the isthmus floor . The preparations corresponded to a proximal connector area of 3 mm × 3 mm for molars and premolars.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* From 18-55 years old, should be able to read and sign the consent document.
* Ability to tolerate the restorative procedures (physical and psychological).
* Good oral hygiene
* Low susceptibility to decay
* Have a minimum coronal tooth height of 5 mm,
* Parallel abutments
* Sufficient mesio distal edentulous gap dimensions.

Exclusion Criteria

* Partially erupted teeth (young)
* Bad oral hygiene and motivation
* Root canal treated teeth
* Psychiatric problems or unrealistic expectations
* Severe para-functional habits
* The absence of enamel on the preparation margins
* Extensive crown defects
* Abutment mobility
Minimum Eligible Age

18 Years

Maximum Eligible Age

55 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Cairo University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

mahmoud osama

clinical professor

Responsibility Role PRINCIPAL_INVESTIGATOR

References

Explore related publications, articles, or registry entries linked to this study.

Gresnigt MM, Kalk W, Ozcan M. Clinical longevity of ceramic laminate veneers bonded to teeth with and without existing composite restorations up to 40 months. Clin Oral Investig. 2013 Apr;17(3):823-32. doi: 10.1007/s00784-012-0790-5. Epub 2012 Jul 21.

Reference Type BACKGROUND
PMID: 22821429 (View on PubMed)

Shillingburg, H.T., Hobo, S. and Whitsett, L. (1997) Fundamentals of fixed prosthodontics. 3rd Edition, Quintessence, Chicago, 119-137, 171-174.

Reference Type BACKGROUND

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CEBD-CU-2018-10-08

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.