Evaluation of Functional Dimensions of Macintosh Laryngoscope Blade During Direct Laryngoscopy in Patients With Normal Mouth Opening
NCT ID: NCT02639897
Last Updated: 2025-03-25
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
100 participants
OBSERVATIONAL
2026-10-31
2030-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Since submucous fibrosis and the associated restricted mouth opening have taken the proposition of an epidemic owing to widespread use of betel nut and tobacco; these patients, when requiring surgery, are difficult candidates for GA and airway control. The fact that, when they arrive as pre-surgical candidates, they have variable degree of mouth opening restriction, which if approached with a strategy, may be amenable to conventional control of airway. If investigators paint all the patients with mouth restriction as difficult airway, it will result in uncalled surgical, economic, health system and psychological burden. Therefore, it is prudent to undertake research relating to refinement of airway access techniques with the easily available, cheap and user- friendly equipment (conventional laryngoscope), such that a proportion of above stated burden can be reduced.
In view of the above, investigators plan to undertake a study to enhance our working knowledge with a conventional laryngoscope (Macintosh) to facilitate ways to control the airway difficulty secondary to mouth opening restriction. Investigators believe that the prospective knowledge thus generated would help us identify whether there is a feasibility of conventional airway management or an alternative advanced access technique is needed in the first place. This will prevent undue cancellations, delayed surgeries, and patient morbidity.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of Video Laryngoscopy in Patients With Head and Neck Pathology
NCT03265938
Glottic Visualization & Ease of Intubation With Different Laryngoscope Blades
NCT01352299
Macintosh Blade Size for Endotracheal Intubation in Operative Rooms
NCT06232837
Comparing Ease of Endotracheal Intubation Using C Blade and D Blade of CMAC Videolaryngoscope in Patients Undergoing Elective Cervical Spine Surgery
NCT05561231
Measurement of Forces Applied Using a Macintosh Direct Laryngoscope Compared to GlideScope Video Laryngoscope
NCT01814176
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Oral submucous fibrosis (SMF) is a well-recognized, potentially malignant progressive condition afflicting the oral cavity that is characterised by a reduced mouth opening. The reduction in mouth opening occurs due a vertical reorientation of collagen fibrils that are normally haphazardly arranged. Of the currently available multiple classifications to identify disease stage/severity, the functional classification based on the inter-incisor distance (IID) seems to be most relevant.
IID forms an important component of airway examination and a value of less than 3-cm is suggestive of difficulty in airway management. However, despite the above, SMF is largely unrecognized as a cause of airway difficulty, and even when recognized, no set protocol is available to ensure (as far as possible) a favourable outcome in terms of least morbidity to the patient, and stress to the anaesthesiology team in question.
Need Assessment for the Study Generally, in a tertiary level centre, with all facilities at hand, cases with a reduced IID are normally tackled using a fiberoptic bronchoscope guided tracheal intubation. However, in India, the burden of this disease lies to a great extent in rural/suburban settings where access to a fiberoptic bronchoscope is unlikely. As a result these cases are referred to 'higher' centres for management. This imposes undue burden (logistics/ financial) onto patients and their families. Hence, there is a great need for anaesthesiologists working at the primary/secondary level healthcare set up to get oriented to this problem and be able to manage it with conventional options (direct laryngoscopy \& intubation) available to them.
Scientific Contention Direct laryngoscopy remains the foremost among the various techniques available to access the upper airway and the Macintosh blade has been the most preferred blade type. In order to improve direct laryngoscopy, many modifications of blade design have been tested/ compared with the Macintosh blade, but apparently, the clarity as to which laryngoscope blade is most suited for a given airway remains low. For the majority of practicing anaesthesiologists, the availability of different laryngoscope designs has only increased the hit-and-trial option for laryngoscopy.
Since the time it was first introduced, the Macintosh blade (size 1, 2, 3, 4, and 5) has weathered many newer laryngoscope blade designs and stood by our side with consistent/optimal performance. Per se, from a technical standpoint, although shaped the same, various sizes of the Macintosh blade are not exactly similar, the discrepancy becomes obvious when comparing sizes 1, 2 with 3 \& 4. Unfortunately, investigators are still unclear as to how design characteristics and the various sizes of the Macintosh blade impact the process of direct laryngoscopy. Generally, the selection of laryngoscope blade (type and sizes) is largely a function of individual experience and preferences. The absence of predefined parameters for the selection of the most appropriate laryngoscope blade for a given airway remains arbitrary. Apparently, an anaesthesiologist will be able to intubate an adult trachea with any of the laryngoscope blade, however, blade type and size selection assumes significance in the presence of a difficult airway.
The three factors which influence successful direct laryngoscopy performance are:
i) The ability to place the laryngoscope blade tip in vallecular recess and engage the hyoid bone. This requires an adequate length of the blade to be introduced orally to reach the vallecula (transition space between base of the tongue and the epiglottis) position.
ii) The ability to displace the tongue aside for clear view to the glottic-epiglottic region iii) Achieving a clear line-of-sight to the glottis-opening. To ensure that the tip of the laryngoscope blade engages the hyoid by placement in the vallecula, an adequate blade length must be inserted into the oral cavity. Normally, this is easily achieved. However, when faced with a situation involving reduced mouth opening/inter-incisor distance (e.g.as in case of SMF), the length of blade that can be inserted into the oral cavity (functional length) becomes a function of the width of the blade's flange at the incisor point. Thus the size of the flange, corresponding to the width of the blade that must be accommodated in the oral cavity assumes particular significance in patients with reduced inter-incisor gap. Typically, for the Macintosh blade's curved design confers different length to its flange's glossal (concave) and the palatal (convex) surface, the functional width of its flange increases from the tip towards the heel \[Figure\]. Based on the degree of mouth opening restriction and the available IID (in cm), during preoperative evaluation, one can predict and plan how long a Macintosh blade length will be required and what size of the blade would suffice to be placed orally through the available IID.
Hypothesis Development Marks et al, utilized an x-ray based method to devise a method to evaluate laryngoscope blade design during active laryngoscopy procedure. Technically, they found that Macintosh sizes 3 and 4 have a more refined blade design that provides greater degree of forward space enhancement (FSE, allows greater mandibular space for the tongue to be moved into) than other conventional blades (Miller, Soper, etc.). This FSE-effect gets further magnified with increase in functional length of the blade (the length of the blade inside the oral cavity during active laryngoscopy).
Their elaborate work addressed the performance of the laryngoscope blade (size, type) selection in a theoretical setting. The information gleaned from their assessment offered valuable suggestions on optimal blade position during direct laryngoscopy and included:
i) Mandibular space 'encroachment/enhancement' with the use of different blade types/sizes, and ii) 'Line-of-vision' (view to the glottis) versus 'mandibular space restriction' (space for tongue displacement during laryngoscopy).
However, still, the clinical feasibility of knowledge thus gained from performance assessment facilitated by x-ray/fluoroscopy is difficult to translate into routine clinical practice.
As the investigator prepares to take the conventional direct laryngoscopy process into difficult airway situations where the primary difficulty is due to reduced mouth opening, there is a need to convert theoretical knowledge into clinical suggestions. Investigators thus contend that unless they get accustomed with greater clarity on the use of routine equipments, and analyse their practical feasibility in difficult situations, the element of randomness and subjectivity will continue to be a setback.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Direct Laryngoscopy
Tracheal intubation with direct laryngoscopy using Macintosh laryngoscope blade
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Both gender
3. Age: 20-65 years
4. Normal preoperative upper airway evaluation and without the presence of anticipated airway access difficulty
5. Patients scheduled for surgery under general anaesthesia with airway control by direct laryngoscopy and tracheal intubation
Exclusion Criteria
2. Anticipated airway access difficulty
3. Edentulous patients
4. Patients with dental problem (missing tooth, overlap, cosmetic treatment)
5. Vulnerable Patients: High risk situation, major surgery, extremes of age, obstetric patients
6. Previously difficult airway
20 Years
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Sir Ganga Ram Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Nitin Sethi, DNB
Consultant
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Amitabh Dutta, MD
Role: STUDY_DIRECTOR
Sir Ganga Ram Hospital, New Delhi, INDIA
Ameya Pappu, MBBS
Role: STUDY_CHAIR
Sir Ganga Ram Hospital, New Delhi, INDIA
Nitin Sethi, DNB
Role: PRINCIPAL_INVESTIGATOR
Sir Ganga Ram Hospital, New Delhi, INDIA
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Sir Ganga Ram Hospital
New Delhi, , India
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
EC/10/15/901
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.