Pulse Pressure Variation Helps to Predict Fluid Responsiveness in Patients Ventilated With Low Tidal Volumes

NCT ID: NCT01569308

Last Updated: 2012-04-03

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

38 participants

Study Classification

OBSERVATIONAL

Study Start Date

2006-05-31

Study Completion Date

2009-10-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Objective: To determine the value of pulse pressure variation (ΔRESPPP) to predict fluid responsiveness in patients ventilated with low tidal volumes (VT), and to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.

Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.

The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.

The study hypothesis is not a good predictor of fluid responsiveness in patients ventilated with low tidal volumes.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Volume expansion is frequently used to treat critically ill patients with acute circulatory failure. The goal of volume expansion is to increase left ventricular stroke volume and consequently cardiac output. However, about 50% of patients with acute circulatory failure will respond to fluid challenge (preload- dependent patients). Therefore, the ability to predict fluid responsiveness in critically ill patients is crucial, particularly for ARDS patients because of increased alveolar-capillary membrane permeability, and avoiding unnecessary fluid loading has been shown to have a positive effect on patient outcome.Among the dynamic parameters used at the bedside to identify fluid responsiveness, pulse pressure variation (ΔRESPPP) is one of the most accurate in patients with acute circulatory failure receiving invasive mechanical ventilation. However, most studies evaluated patients ventilated with large tidal volumes (≥ 8 ml/kg). Therefore, the validity of ΔRESPPP to identify fluid responsiveness is still debated when lower tidal volumes are used.

The current literature about its performance during ventilation with low tidal volumes is unclear, and opposite conclusions have been drawn. The present study was designed to (1) determine the value of ΔRESPPP to predict fluid responsiveness in patients ventilated with low tidal volumes, and (2) to investigate whether a lower ΔRESPPP cut-off point should be used when patients are ventilated with low tidal volumes.

Methods: This cross-sectional, observational study included 37 critically ill patients with acute circulatory failure requiring fluid challenge. They were sedated and mechanically ventilated with Tidal Volume (VT) 6-7 ml/kg IBW (ideal body weight), monitored by pulmonary artery catheter and arterial line. Mechanical ventilation and hemodynamic parameters, including ΔRESPPP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase of at least 15% in cardiac index.

Patients were followed for 28 days or until discharge from the ICU.

Study Protocol Patients were sedated with midazolan and fentanyl (score of -4 to -5 in the Richmond Agitation Sedation Scale)and ventilated in controlled pressure or controlled volume mode (Servo I system v.12 or Servo 900 C, Siemens, Sweden) with VT \< 8 ml/kg IBW (51 + 0.9\[height in cm- 152.9\] for men and 45.5 + 0.91\[height in cm- 152.9\] for women). Ventilatory and hemodynamic variables were measured before and after FC with the patients in a supine position. Zero pressure was measured at the midaxillary line. The correct position of the pulmonary artery catheter in West's zone 3 was checked as described in the literature.

Fluid challenge was performed with 1000 ml 0.9% saline solution or lactated Ringer's solution (n=36) or 500 ml hydroxy-ethyl-starch solution 6% 130/0.4 for 30 minutes (n=2).

Hemodynamic Parameters

Variations in arterial pulse pressure were visualized on bedside monitors (HP S66 and PHILIPS IntelliVue, MP60, Germany) and measured with the cursor for each of 5 breathing cycles. ΔRESPPP was calculated using the following equation:

ΔRESPPP (%) = 100 x (PPmax - PPmin) / \[(PPmax + PPmin)/2\]

where PPmax and PPmin are the maximal pulse pressure at inspiration and the pulse pressure obtained on expiration, respectively.

A pulmonary artery catheter (Edwards Healthcare, Irvine, CA) was used to measure cardiac output according to the thermal dilution method (3 injections of 10ml 0.9% saline solution), systolic, diastolic and mean pulmonary arterial pressures, pulmonary artery occlusion pressure (PAOP, mmHg), central venous pressure (CVP, mmHg), and mixed venous saturation (SvO2). Mean arterial pressure (MAP, mmHg), measured using the arterial line, and heart rate (HR, bpm) were also recorded. All measurements were made at the end of expiration, before and after FC. Patients were defined as fluid responders when cardiac index increased at least 15% of baseline value.

Ventilation Parameters The following ventilatory parameters were measured: inspiratory and expiratory tidal volume, respiratory rate (RR), plateau pressure (cmH2O), peak pressure (cmH2O), total positive end-expiratory pressure (PEEPtot), static compliance (Cst) and driving pressure (DP= Pplat-PEEP). All measurements were made before and after FC.

Statistical Analysis Sample size was defined as 38 patients for estimation of the correlation between CI and ΔRESPPP 0.5 (moderate to high magnitude), with a level of significance of 0.05 and power of 90%.

The effects of FC on hemodynamic parameters were assessed using a paired Student's t-test for normally distributed variables or a nonparametric Wilcoxon Signed Rank test for non-normally distributed variables. The comparison of hemodynamic parameters between both groups at baseline and after FC was assessed using a two sample Student's t-test or a nonparametric Mann-Whitney U test. Results were expressed as mean values±SD or median (25-75 percentiles).

Receiver operating characteristic (ROC) curves were constructed to evaluate the ability of ΔRESPPP, ΔRESPPP/DP, CVP and PAOP to predict fluid responsiveness. The best cut-off value for ΔRESPPP ROC curve was determined for the entire population. In addition, measures of diagnostic performance were calculated: sensitivity, specificity, predictive values and likelihood ratio. Linear correlations were tested using the Spearman rank method. Data were analyzed using SPSS 15.0. A p value \<0.05 was considered significant.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hemodynamic Instability

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

CROSS_SECTIONAL

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age ≥ 16 years
* Hemodynamic instability defined as need for norepinephrine infusion and/or intravascular fluid administration to maintain systolic arterial blood pressure \> 90 mm Hg
* Arterial line in place (radial or femoral)
* Pulmonary arterial catheter in place

Exclusion Criteria

* Presence of cardiac arrhythmias
* Presence of pneumothorax
* Presence of heart valve disease or intracardiac shunt
* Previously diagnosed right ventricular insufficiency
Minimum Eligible Age

16 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Hospital de Clinicas de Porto Alegre

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Gilberto Friedman

Role: PRINCIPAL_INVESTIGATOR

Hospital de Clinicas de Porto Alegre

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hospital de Clinicas de Porto Alegre

Porto Alegre, Rio Grande do Sul, Brazil

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Brazil

References

Explore related publications, articles, or registry entries linked to this study.

Oliveira-Costa CD, Friedman G, Vieira SR, Fialkow L. Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes. Clinics (Sao Paulo). 2012 Jul;67(7):773-8. doi: 10.6061/clinics/2012(07)12.

Reference Type DERIVED
PMID: 22892922 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

06-109

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Effects of End-inspiratory Pause on Ventilation
NCT06692634 NOT_YET_RECRUITING NA