The Impact of Force Feedback in the dV5 Robotic Surgical System on Learning Curve and Safety in Robot-Assisted Radical Prostatectomy - A Prospective, Single-Center, Investigator-Initiated Clinical Trial

NCT ID: NCT07247175

Last Updated: 2025-11-25

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

PHASE2

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2026-01-01

Study Completion Date

2027-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This single-center, investigator-initiated prospective clinical study aims to evaluate the impact of the Force Feedback function of the da Vinci 5 (dV5) robotic surgical system on surgical skill acquisition and intraoperative safety during robot-assisted radical prostatectomy (RARP). Although robotic surgery is well established in urology, the absence of tactile sensation remains a major limitation of previous systems. The new dV5 platform incorporates real-time haptic (force) feedback, potentially reducing excessive tissue traction and improving surgical precision.

A total of 60 patients with clinically localized prostate cancer will be enrolled at Samsung Medical Center. Two surgeons (one faculty and one trainee) will each perform 30 RARP cases, with Force Feedback ON/OFF randomly assigned for each case. The primary endpoints are (1) mean traction force and (2) total instrument path length during seminal vesicle dissection. Secondary endpoints include surgical performance metrics (time, clutch counts), intraoperative safety, postoperative complications, and patient-reported outcomes (IPSS, IIEF-5, EPIC-CP, ICIQ-UI SF). Data will be analyzed using mixed-effects models accounting for surgeon-level random effects.

This study seeks to provide quantitative evidence on how Force Feedback enhances surgical learning efficiency, precision, and patient safety in next-generation robotic prostate surgery.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This prospective, single-institution, investigator-initiated clinical trial investigates how the Force Feedback (haptic sensing) technology in the da Vinci 5 (dV5) robotic surgery platform influences technical skill acquisition and safety in robot-assisted radical prostatectomy (RARP). The study is conducted at Samsung Medical Center (Seoul, Korea) under the supervision of Professor Seong Soo Jeon and Dr. Jiwoong Yu from the Department of Urology.

Robotic-assisted surgery has revolutionized minimally invasive prostate cancer treatment, but conventional robotic systems (e.g., da Vinci Xi) lack tactile feedback, forcing surgeons to rely solely on visual cues. This limitation may lead to excessive force application and increase the risk of tissue injury. The dV5 system introduces a Force Feedback mechanism that allows surgeons to feel real-time resistance transmitted through the robotic arms. Preclinical reports suggest this reduces applied forces by up to 40-50% and improves precision, especially during the learning phase. However, objective clinical data quantifying these benefits are limited.

The present trial will enroll 60 patients diagnosed with clinically localized prostate cancer (cT1-T3a, N0, M0) eligible for RARP. Two surgeons-a senior faculty (expert) and a urology resident (trainee)-will each perform 30 RARP cases. For each surgery, the Force Feedback function will be randomly assigned (ON vs. OFF) while maintaining identical operative conditions. The seminal vesicle dissection step is chosen as the standardized assessment phase since it is technically demanding yet safe for educational evaluation.

Primary endpoints are:

Mean traction force applied to tissue (N)

Total instrument path length (m) during seminal vesicle dissection

Secondary endpoints include:

Surgical performance metrics: operative time, clutch counts, peak force, efficiency indicators, and cumulative sum (CUSUM) learning curves.

Safety parameters: estimated blood loss, complications (graded by Clavien-Dindo), hospital stay, and biochemical recurrence.

Patient-reported outcomes: urinary, sexual, and overall quality of life assessed by validated questionnaires (IPSS, IIEF-5, EPIC-CP, ICIQ-UI SF).

Procedural efficiency metrics such as lens-cleaning frequency and suction count.

All operations will be video-recorded and digitally logged using dV5 Case Insight software, which captures objective performance indicators (OPIs) including instrument trajectory, applied force, and clutch frequency. Statistical analysis will use linear mixed-effects models with Force Feedback status and case sequence as fixed effects, and surgeon ID as a random effect, allowing adjustment for intra-surgeon correlations and learning effects.

Safety monitoring follows institutional IRB and KGCP guidelines. All adverse events (AEs) and device deficiencies will be documented, with serious adverse events (SAEs) reported within 24 hours. Standard perioperative management and intraoperative supervision by experienced faculty will ensure patient safety.

This study is designed as a pilot exploratory analysis that integrates human performance data, haptic sensor output, and clinical outcomes. Findings will offer the first objective evidence on how haptic feedback influences both novice and expert robotic surgeons in terms of force modulation, precision, efficiency, and safety. The results may guide the optimization of training curricula and inform the development of future robotic platforms incorporating tactile intelligence.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Prostate Cancer

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Force-feedback on

Group Type EXPERIMENTAL

Force-feedback on

Intervention Type DEVICE

In this study, the "Force-Feedback ON" intervention refers to performing robotic-assisted radical prostatectomy using the da Vinci 5 (dV5) system with its haptic feedback function activated. When this mode is ON, miniature force sensors built into the robotic instruments continuously detect the mechanical resistance encountered at the instrument tips and transmit it back to the surgeon's hand controllers in real time.

This tactile feedback allows the operator to feel the intensity and direction of traction or pressure applied to tissues, enabling finer motion control, reduced tissue stress, and safer dissection. In contrast, when Force Feedback is OFF, the surgeon relies solely on visual cues, as in all previous-generation robotic systems.

Thus, "Force-Feedback ON" represents an active tactile-sensing mode designed to enhance precision, promote gentler handling, and improve training efficiency during robotic surgery.

Force-feedback off

Group Type SHAM_COMPARATOR

Forece-feedback off

Intervention Type DEVICE

Off force-feedback function

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Force-feedback on

In this study, the "Force-Feedback ON" intervention refers to performing robotic-assisted radical prostatectomy using the da Vinci 5 (dV5) system with its haptic feedback function activated. When this mode is ON, miniature force sensors built into the robotic instruments continuously detect the mechanical resistance encountered at the instrument tips and transmit it back to the surgeon's hand controllers in real time.

This tactile feedback allows the operator to feel the intensity and direction of traction or pressure applied to tissues, enabling finer motion control, reduced tissue stress, and safer dissection. In contrast, when Force Feedback is OFF, the surgeon relies solely on visual cues, as in all previous-generation robotic systems.

Thus, "Force-Feedback ON" represents an active tactile-sensing mode designed to enhance precision, promote gentler handling, and improve training efficiency during robotic surgery.

Intervention Type DEVICE

Forece-feedback off

Off force-feedback function

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Male patients aged ≥19 years.

Histologically confirmed localized prostate cancer, clinical stage T1-T3a, N0, M0.

Scheduled to undergo robot-assisted radical prostatectomy (RARP) at Samsung Medical Center.

No radiologic evidence of distant metastasis, and disease deemed surgically resectable via robotic approach.

Medically fit for general anesthesia and laparoscopic surgery, classified as ASA physical status I-III.

Baseline erectile function preserved, defined as IIEF-5 ≥12 within 6 months prior to surgery.

Provided written informed consent for participation after full explanation of the study.

Exclusion Criteria

* Locally advanced or metastatic prostate cancer (clinical stage ≥T3b, N1, or M1\*\*).

Prostate volume ≥60 cc on preoperative MRI, which may complicate robotic dissection standardization.

History of pelvic radiotherapy for any malignancy.

Previous androgen deprivation therapy (ADT) or other hormonal therapy for prostate cancer.

History of prior prostate surgery, such as TURP or HoLEP.

History of spinal cord injury or major pelvic surgery that may alter pelvic anatomy.

Medical contraindications to robotic/laparoscopic surgery or general anesthesia (e.g., severe cardiopulmonary disease, ASA ≥ IV).

Anatomic limitations (e.g., extreme obesity or deformity) precluding safe robotic access.

Device or software malfunction preventing proper activation or deactivation of the Force Feedback system.

Any other condition deemed inappropriate for study participation by the principal investigator (e.g., cognitive impairment affecting consent or follow-up).
Minimum Eligible Age

19 Years

Eligible Sex

MALE

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Seong Soo Jeon

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Seong Soo Jeon

Professor

Responsibility Role SPONSOR_INVESTIGATOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2025-05-021-003

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.