Post-Approval Study of PALMAZ MULLINS XD™ in Treating Pulmonary Artery Stenosis
NCT ID: NCT07122518
Last Updated: 2025-08-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
75 participants
OBSERVATIONAL
2025-12-31
2027-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Pulmonary Artery Repair With Covered Stents
NCT01824160
Evaluation of the Valiant Captivia Physician Fenestrated Stent Graft System in Aortic Arch and Descending Thoracic Aorta Pathologies
NCT05479305
PMCF Study of Precise Pro Rx for Carotid Artery Disease
NCT07204678
DESolve® X-Pand Global Post Market Registry
NCT02453035
Feasibility of Endovascular Repair of Ascending Aortic Pathologies
NCT03322033
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The study will collect the performance and safety data of the PALMAZ MULLINS XD™ Pulmonary Stent through time of hospital discharge.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Palmaz Mullins XD™ Treatment
All enrolled subjects are treated with the PALMAZ MULLINS XD™ Pulmonary Stent
PALMAZ MULLINS XD™ Pulmonary Stent
The PALMAZ MULLINS XD™ Pulmonary Stent is indicated for the non-emergency treatment of pulmonary artery stenosis in pediatric patients who are at least 10kg in weight with two ventricle anatomy. The PALMAZ MULLINS XD™ Pulmonary Stent is a balloon-expandable, laser cut stent made from 316L stainless steel tubing. The stent is supplied unmounted and in five (5) nominal unexpanded lengths: 19 mm, 25 mm, 29 mm, 39 mm, and 59 mm.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PALMAZ MULLINS XD™ Pulmonary Stent
The PALMAZ MULLINS XD™ Pulmonary Stent is indicated for the non-emergency treatment of pulmonary artery stenosis in pediatric patients who are at least 10kg in weight with two ventricle anatomy. The PALMAZ MULLINS XD™ Pulmonary Stent is a balloon-expandable, laser cut stent made from 316L stainless steel tubing. The stent is supplied unmounted and in five (5) nominal unexpanded lengths: 19 mm, 25 mm, 29 mm, 39 mm, and 59 mm.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
21 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Congenital Cardiovascular Interventional Study Consortium (CCISC)
UNKNOWN
Cordis Corporation
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
P23-8501
Identifier Type: -
Identifier Source: org_study_id
More Related Trials