Early Feasibility Study of the RelayBranch Thoracic Stent-Graft System
NCT ID: NCT03214601
Last Updated: 2025-05-31
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
30 participants
INTERVENTIONAL
2017-12-04
2028-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This Early Feasibility Study (EFS) will assess the safety and effectiveness of the device at the index procedure and at 30-day follow-up. The study will evaluate the delivery and deployment of the device, patency of branches and branch vessels, and exclusion of the aortic pathology. The data will help determine if modifications need to be made to the device, the procedural steps, operator technique, or the indications for use.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Phase II Study of the Safety and Efficacy of the Relay Thoracic Stent-Graft
NCT00435942
Phase II Clinical Study of the Safety and Efficacy of the Relay Thoracic Stent-Graft
NCT01327742
Study of the Relay Pro® Thoracic Stent-Graft in Subjects With Traumatic Injury of the Descending Thoracic Aorta
NCT03090230
RelayPro Thoracic Stent-Graft in Subjects With Thoracic Aortic Aneurysms and Penetrating Atherosclerotic Ulcers
NCT02818972
Study of the RelayPro Thoracic Stent-Graft in Subjects With an Acute, Complicated Type B Aortic Dissection
NCT03033043
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The study will evaluate three-dimensional (3D) imaging data, both at baseline and through follow-up. Baseline 3D anatomy will augment information on the precise anatomic configuration of patients presenting aortic arch pathology treatable with the device. Follow-up imaging will provide information on the effectiveness of the device with respect to endoleaks in patients with aneurysms, sealing of dissections, PAU and IMH, and stability of the device at the deployed position, response, endograft patency, and short-term device integrity.
The data from this EFS will yield insights into the following aspects of the device, preceding a traditional feasibility or pivotal study:
* The clinical safety of the device-specific aspects of the procedure,
* Determination of delivery and deployment of the device,
* Operator-dependent aspects of device use,
* Human factors associated with the design and use of the device,
* Safety of the device as assessed by device-related adverse events,
* Effectiveness of the device in performing its intended purpose over short-term follow-up.
Observations from the study will guide the instructions for use (IFU) for the device. Finally, the study will collect imaging data to augment the current use conditions data set. It is anticipated that information collected will be used to make applicable design changes, or be combined with a prospective, investigational device exemption (IDE) study for submission of an original premarket approval application (PMA) to the U.S. Food and Drug Administration (FDA) for approval to commercially distribute the system.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Relay Branch System
Subjects who receive the Relay Branch System for repair which includes those with aneurysmal disease, penetrating atherosclerotic ulcer (PAU), and chronic uncomplicated Type B aortic dissection.
penetrating atherosclerotic ulcer, aorta branch cardiovascular implant
The Relay Branch System is intended to provide an option for patients with arch and proximal descending chronic thoracic aortic pathologies.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
penetrating atherosclerotic ulcer, aorta branch cardiovascular implant
The Relay Branch System is intended to provide an option for patients with arch and proximal descending chronic thoracic aortic pathologies.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Anatomy that would require coverage of the brachiocephalic trunk (BCT) and/or left carotid arteries if a non-branch endograft were implanted
* At least one of the following:
a. Aneurysm of the ascending aorta, aortic arch, or proximal descending aorta that meets at least one of the following: i. ≥ 5.5 cm in diameter ii. ≥ 4.0 cm in diameter that has increased in size by 0.5 cm in the last 6 months iii. Measures twice the size of the normal aorta diameter iv. Is saccular in configuration
b. PAU within the ascending aorta, aortic arch, or proximal descending thoracic aorta (DTA) with or without intramural hematoma (IMH)
c. Chronic, uncomplicated aortic dissection distal to the BCT (type B), with either aortic diameter ≥5.5 cm or ≥4.0 cm with an increase in size by 0.5 cm in the last 6 months d. IMH distal to the BCT with recurrent symptoms, i.e. hypertension or intractable pain, despite best medical therapy.
* A non-aneurysmal proximal aortic neck diameter ranging between 28 mm and 43 mm and a non-aneurysmal distal aortic neck diameter ranging between 19 mm and 43 mm.
* A proximal attachment zone of the arch graft, meeting the oversizing requirement, must be a minimum of 25mm in length when measured on the inner curve of the ascending aorta, proximal to the BCT.
* Total length from the coronaries to the proximal edge of the BCT must be a minimum of 70mm.
* The length of the distal landing zone should be 20mm minimum.
* Coverage of the left subclavian artery is permitted. Revascularization of the left subclavian artery may be considered in all cases by the treating physician and, especially, in anatomies where revascularization is determined to be clinically necessary
* The distal landing zone must contain a straight segment (non-tapered, non-reverse tapered; defined by \< 10% diameter change) with length equal to or greater than the required attachment length of the intended device
* Non-aneurysmal BCT and left common carotid arteries with diameters ranging \> 6.0mm across the entire length of the treatment zone.
* Distal branch landing zone must be \<20.0 mm in diameter and a minimum of 25.0 mm in length.
* Adequate arterial access for introduction and delivery of the Relay Branch System. Note: Alternative methods to gain proper access can be utilized (e.g., iliac conduit)
* Considered high risk or prohibitive risk for conventional surgery by treating physician or aortic team
* Must be willing to comply with the follow-up evaluation schedule
* Subject or legally authorized representative must sign the informed consent form prior to implant.
Exclusion Criteria
* Aortic angulations (radius) less than 15mm at intended proximal landing zone.
* Ascending aortas that would require the arch graft to be deployed less than 15mm distal to the coronaries
* Pre-procedure occlusion or planned coverage of both subclavian arteries
* Anatomic variants which would compromise circulation to both vertebral arteries after placement of the stent-graft
* Prior endovascular repair in the ascending/descending thoracic aorta or aortic arch. The device may not be placed within any prior endovascular graft
* Concomitant aneurysm/disease of the abdominal aorta requiring repair
* Prior abdominal aortic aneurysm repair (endovascular or surgical) that was performed less than 6 months prior to the planned stent implant procedure
* Prior mechanical aortic valve replacement except for hybrid valves with biological leaflets.
* Major surgical or medical procedure within 45 days prior to the planned procedure or is scheduled for a major surgical or medical procedure within 60 days post implantation. Except for any planned procedures for the prospective stent-graft placement, e.g., left subclavian artery bypass or transposition
* Untreatable allergy or sensitivity to contrast media or device components
* Blood coagulation disorder or bleeding diathesis in which the treatment cannot be suspended for one week pre and post repair
* Acute Coronary Syndrome (ACS) including unstable angina
* Severe Congestive Heart Failure (New York Heart Association functional class IV)
* Stroke within 12 months of the planned treatment date
* Myocardial infarction within 3 months of the planned treatment date.
* Chronic atrial fibrillation or other hypercoagulable condition that requires treatment with anticoagulants or presence of left atrial appendage thrombus
* Severe pulmonary disease (documented FEVI \<30% or as assessed by the study physician) at screening
* Acute renal failure (defined as serum creatinine \> 2.5mg/dL Note: Patients that have chronic renal failure and are managed medically or through hemodialysis, and can tolerate the follow-up imaging schedule can be included.
* Significant carotid bifurcation disease (\>70% diameter reduction by duplex ultrasound or angiography)
* Hemodynamic instability
* Active systemic infection at the time of treatment
* Morbid obesity or other condition that may compromise or prevent the necessary imaging requirements
* Connective tissue disorders, mycotic aneurysms, or infected aorta
* Less than two-year life expectancy
* Current or planned participation in an investigational drug or device study that has not completed primary endpoint evaluation
* Currently pregnant or planning to become pregnant during the course of the study
* Medical, social, or psychological issues that the Investigator believes may interfere with treatment or follow-up
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Bolton Medical
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Luis Sanchez, MD
Role: PRINCIPAL_INVESTIGATOR
Barnes Jewish Hospital, Washington Univ
Wilson Szeto, MD
Role: PRINCIPAL_INVESTIGATOR
Penn Presbyterian Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Southern California
Los Angeles, California, United States
University of Florida
Gainesville, Florida, United States
Emory University
Atlanta, Georgia, United States
University of Maryland
Baltimore, Maryland, United States
Massachusetts General Hospital
Boston, Massachusetts, United States
Barnes Jewish Hospital at Washington University
St Louis, Missouri, United States
Columbia University Medical Center
New York, New York, United States
Duke University
Durham, North Carolina, United States
Cleveland Clinic
Cleveland, Ohio, United States
Hospital of the University of Pennsylvania/Penn Presbyterian
Philadelphia, Pennsylvania, United States
Baylor College of Medicine
Houston, Texas, United States
Baylor Scott and White Research Institute
Plano, Texas, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IP-0019-16
Identifier Type: -
Identifier Source: org_study_id