Comparison Volume-controlled Ventilation, Pressure-controlled Volume-guaranteed Ventilation, and Pressure-controlled Ventilation During Gynecologic Laparoscopic Surgery in the Steep Trendelenburg Position
NCT ID: NCT06861959
Last Updated: 2025-03-10
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
60 participants
INTERVENTIONAL
2021-01-01
2021-09-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This study aimed to compare the effects of three different mechanical ventilation modes-Volume-Controlled Ventilation (VCV), Pressure-Controlled Ventilation (PCV), and Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG)-on pulmonary and hemodynamic variables during laparoscopic gynecologic surgery in the steep Trendelenburg position. The hypothesis was that PCV and PCV-VG would be superior to VCV in optimizing respiratory mechanics and improving oxygenation, particularly by reducing peak inspiratory pressure (Ppeak).
Methods:
Prospective, randomized, controlled clinical trial. Sixty ASA I-III patients aged 20-65 years undergoing elective laparoscopic gynecologic surgery in the steep Trendelenburg position were included (20 patients per ventilation group).
Patients were randomized into VCV, PCV, and PCV-VG groups. Intraoperative ventilation was performed with a tidal volume of 8 mL/kg, PEEP of 5 cmH2O, and intra-abdominal pressure maintained at 12-14 mmHg.
Data were collected at four time points: T1 (after induction, supine), T2 (30 min after CO2 insufflation, Trendelenburg), T3 (60 min after pneumoperitoneum), and T4 (after CO2 deflation, supine).
Primary outcome: Ppeak comparison between groups. Secondary outcomes: Dynamic lung compliance (Cdyn), mean inspiratory pressure (Pmean), gas exchange, and hemodynamic parameters.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Effects of VC Versus PC Ventilation on Cerebral and Respiratory Parameters in Patients Undergoing Laparoscopic Gynecologic Surgery
NCT06482983
The Effect of Intraoperative Ventilation Mode on Hemodynamics and Lung Dynamics
NCT05776589
Comparison of Three Modes of Ventilation During Robot-assisted Hysterectomy in Trendelenburg Position
NCT03887949
A Comparative Study of Ventilation Strategies in Different Surgical Positions on Intracranial Pressure and Cerebral Blood Flow During Laparoscopic Surgery
NCT06805747
Pressure Controlled Ventilation Versus Volume Controlled Ventilation in Upper Abdominal Surgery
NCT05690867
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
OTHER
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group VCV
Patients in this group were ventilated using Volume-Controlled Ventilation (VCV) mode throughout the procedure.
Device: Volume-Controlled Ventilation (VCV)
Tidal volume: 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Group PCV
Patients in this group were ventilated using Pressure-Controlled Ventilation (PCV) mode throughout the procedure.
Device: Pressure-Controlled Ventilation (PCV)
Initial peak inspiratory pressure adjusted to deliver a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Group PCV-VG
Patients in this group were ventilated using Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG) mode throughout the procedure.
Device: Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG)
Pressure-controlled mode with volume guarantee to maintain a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Device: Volume-Controlled Ventilation (VCV)
Tidal volume: 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Device: Pressure-Controlled Ventilation (PCV)
Initial peak inspiratory pressure adjusted to deliver a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Device: Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG)
Pressure-controlled mode with volume guarantee to maintain a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Classified as American Society of Anesthesiologists (ASA) physical status I or III
* who were scheduled to undergo an elective laparoscopic gynecologic surgery with pneumoperitoneum lasting at least one hour in the steep Trendelenburg position.
Exclusion Criteria
* pulmonary or cardiac diseases (e.g., chronic obstructive pulmonary disease, heart failure)
* a history of difficult intubation
* Patients requiring conversion to laparotomy or experiencing hemodynamic instability during surgery
20 Years
65 Years
FEMALE
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Dr. Lutfi Kirdar Kartal Training and Research Hospital
OTHER_GOV
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
kübra taşkın
anesthesiology and reanimation specialist doctor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Zeynep Kamil Maternity and Children's Training and Research Hospital
Istanbul, Üsküdar, Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Toker MK, Altiparmak B, Uysal AI, Demirbilek SG. [Comparison of pressure-controlled volume-guaranteed ventilation and volume-controlled ventilation in obese patients during gynecologic laparoscopic surgery in the Trendelenburg position]. Braz J Anesthesiol. 2019 Nov-Dec;69(6):553-560. doi: 10.1016/j.bjan.2019.09.003. Epub 2019 Dec 10.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
keahanest
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.