Investigation of the Effect of Low Torque and Speed on Post-Operative Pain After Root Canal Treatment
NCT ID: NCT06309095
Last Updated: 2024-03-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
NOT_YET_RECRUITING
NA
80 participants
INTERVENTIONAL
2024-03-15
2024-04-15
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Low torque and speed values mean low pressure applied by the instruments in the root canal. With low forces and vibrations, motor noise is generally negligible, and the instruments can easily shape most root canals in a reasonable amount of time and with minimal mechanical stress (in medium-easy canals). The use of lower torque values has been shown to reduce cyclic fatigue of Ni-Ti rotary tools. With reduced cyclic fatigue, the risk of instrument breakage in complex root canal morphologies is minimized and complications that may occur during root canal treatment are reduced. However, with low torque and speed values, cutting efficiency decreases and the process time increases as the instrument advances in the canal and during possible treatment. Decreasing cutting efficiency may also result in the operator applying force to move through the canal. With the applied force, the friction resistance within the canal increases and the heat produced increases. For this reason, it is thought that the risk of post-operative pain may increase during or after the procedure.
The aim of this study is to investigate the incidence of post-operative pain and procedure time using the visual analog scale (VAS) among groups where low torque and speed values were applied during the use of the Ni-Ti rotary instrument system.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Can the Different Instruments Used ın Root Canal Treatment Have an Effect on Postoperative Pain?
NCT05927025
Postoperative Pain After Using NiTi Instruments
NCT04700995
Radicular Dentin Remaining, Risk of Perforation and Canal Transportation in Manual Versus Rotary Instrumentation in Primary Molars
NCT04793308
Effect of Different Apical Actions on Local Inflammatory Mediators and Pain
NCT06760312
Postoperative Pain Intensity Associated With the Use of Different Nickel Titanium Instrumentation Systems
NCT03478241
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients meeting the inclusion criteria will be randomly divided into four groups (n=20) using a website (www.randomizer.org). The patient number and the randomized group from which the patient was selected will be recorded. All patients will be subjected to local anesthesia with articaine hydrochloride (Maxicaine, Istanbul) containing 1:100,000 adrenaline. After the entrance cavities of the teeth are opened with an aerator under water cooling, a rubber dam will be applied to the relevant teeth for isolation from the oral environment. After the entrance cavity is opened, the working length of the canals will be determined with the help of a No. 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) canal file and an electronic apex finder (Woodpex III, Woodpecker Medical Instrument Co, Guilin, China). In both groups, it was planned to use the NiTi rotary instrument system using V Taper Gold (Fanta Dental Material, Shanghai, China) files with the help of VDW.Silver endomotor (VDW, München, Germany). The patient groups were determined as the first group was 2N torque value and 350 rpm speed, the second group was 2N torque and 250 rpm speed, the third group was 1N torque and 350 rpm speed, and the fourth group was 1N torque and 250 rpm speed. The torque values to be applied are lower than the values recommended by the manufacturer and there is no harm in applying them in the literature. For irrigation of root canals, 2ml of 2.5% sodium hypochlorite will be used at each instrument change. For final irrigation, 17% EDTA( ethylenediaminetetraacetic acid) solution will be used. Root canals will be dried using sterile paper points. The root canals will be filled using gutta percha and a resin-containing root canal sealer (Dentsply Maillefer, Ballaigues, Switzerland) and the treatment will be completed by making the upper restoration. After the treatment, patients were given a VAS scale (Visual Analog Scale) and were instructed how to fill in their pain levels verbally and visually, 6, 12, 48, 72 hours and 1 week later. With the VAS scale, patients will be asked to note whether they use the prescribed Ibuprofen analgesic and the frequency of use. When patients come to their follow-up appointment, the forms will be taken from the patients and their post-treatment pain values will be compared. The collected data will be analyzed statistically with one-way ANOVA and post hoc Tukey tests.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
1 N (Newton) torque, 250 rpm(rotary per minute) speed
The values specified in the endomotor will be used during root canal treatment. 1 N torque, 250 rpm speed
use of VDW Silver Endodontic motor
All patients will be subjected to local anesthesia with articaine hydrochloride (Maxicaine, Istanbul) containing 1:100,000 adrenaline. After the entrance cavities of the teeth are opened, a rubber dam will be applied to the relevant teeth for isolation from the oral environment. After the entrance cavity is opened, the working length of the canals will be determined with the help of a No. 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) canal file and an electronic apex finder (Woodpex III, Woodpecker Medical Instrument Co, Guilin, China). In both groups, it was planned to use the NiTi rotary instrument system using V Taper Gold (Fanta Dental Material, Shanghai, China) files with the help of VDW.Silver endomotor (VDW, München, Germany). The endodontic motor will be used to adjust different speed and torque values during root canal treatment. Post-operative pain caused by different speed and torque values will be compared.
1 N torque, 350 rpm speed
The values specified in the endomotor will be used during root canal treatment. 1 N torque, 350 rpm speed
use of VDW Silver Endodontic motor
All patients will be subjected to local anesthesia with articaine hydrochloride (Maxicaine, Istanbul) containing 1:100,000 adrenaline. After the entrance cavities of the teeth are opened, a rubber dam will be applied to the relevant teeth for isolation from the oral environment. After the entrance cavity is opened, the working length of the canals will be determined with the help of a No. 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) canal file and an electronic apex finder (Woodpex III, Woodpecker Medical Instrument Co, Guilin, China). In both groups, it was planned to use the NiTi rotary instrument system using V Taper Gold (Fanta Dental Material, Shanghai, China) files with the help of VDW.Silver endomotor (VDW, München, Germany). The endodontic motor will be used to adjust different speed and torque values during root canal treatment. Post-operative pain caused by different speed and torque values will be compared.
2 N torque, 250 rpm speed
The values specified in the endomotor will be used during root canal treatment. 2 N torque, 250 rpm speed
use of VDW Silver Endodontic motor
All patients will be subjected to local anesthesia with articaine hydrochloride (Maxicaine, Istanbul) containing 1:100,000 adrenaline. After the entrance cavities of the teeth are opened, a rubber dam will be applied to the relevant teeth for isolation from the oral environment. After the entrance cavity is opened, the working length of the canals will be determined with the help of a No. 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) canal file and an electronic apex finder (Woodpex III, Woodpecker Medical Instrument Co, Guilin, China). In both groups, it was planned to use the NiTi rotary instrument system using V Taper Gold (Fanta Dental Material, Shanghai, China) files with the help of VDW.Silver endomotor (VDW, München, Germany). The endodontic motor will be used to adjust different speed and torque values during root canal treatment. Post-operative pain caused by different speed and torque values will be compared.
2 N torque, 350 rpm speed
The values specified in the endomotor will be used during root canal treatment. 2 N torque, 350 rpm speed
use of VDW Silver Endodontic motor
All patients will be subjected to local anesthesia with articaine hydrochloride (Maxicaine, Istanbul) containing 1:100,000 adrenaline. After the entrance cavities of the teeth are opened, a rubber dam will be applied to the relevant teeth for isolation from the oral environment. After the entrance cavity is opened, the working length of the canals will be determined with the help of a No. 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) canal file and an electronic apex finder (Woodpex III, Woodpecker Medical Instrument Co, Guilin, China). In both groups, it was planned to use the NiTi rotary instrument system using V Taper Gold (Fanta Dental Material, Shanghai, China) files with the help of VDW.Silver endomotor (VDW, München, Germany). The endodontic motor will be used to adjust different speed and torque values during root canal treatment. Post-operative pain caused by different speed and torque values will be compared.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
use of VDW Silver Endodontic motor
All patients will be subjected to local anesthesia with articaine hydrochloride (Maxicaine, Istanbul) containing 1:100,000 adrenaline. After the entrance cavities of the teeth are opened, a rubber dam will be applied to the relevant teeth for isolation from the oral environment. After the entrance cavity is opened, the working length of the canals will be determined with the help of a No. 10 K-file (Dentsply Maillefer, Ballaigues, Switzerland) canal file and an electronic apex finder (Woodpex III, Woodpecker Medical Instrument Co, Guilin, China). In both groups, it was planned to use the NiTi rotary instrument system using V Taper Gold (Fanta Dental Material, Shanghai, China) files with the help of VDW.Silver endomotor (VDW, München, Germany). The endodontic motor will be used to adjust different speed and torque values during root canal treatment. Post-operative pain caused by different speed and torque values will be compared.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patients who have no physical or psychological disabilities and are competent in understanding and applying treatment protocols
* Mandibular first molars without preoperative pain,
* The relevant tooth is devital (non-living)
* Teeth that have not had root canal treatment before,
* Teeth that have not been traumatized and have no serious dental malposition,
* Teeth that do not have complex root canal morphology,
* Patients whose root curvature is not \>25°,
* Patients without sinus tract, periapical abscess and cellulitis,
Exclusion Criteria
* Patients who have used cortisone in the last 6 months and analgesic-anti-inflammatory-antibiotic use in the last week
* The patient is allergic to one or more of the agents to be used during the procedure.
18 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Afyonkarahisar Health Sciences University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ahmet Demirhan Uygun
Associate Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ahmet D Uygun, Assoc. Prof.
Role: STUDY_CHAIR
Afyonkarahisar Health Science University/ Dentistry Faculty
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Afyonkarahisar Health Science University
Afyonkarahisar, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
AFSU_AhmetDemirhanUygun_001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.