Incidence of Post-Operative Pain After Single Visit Root Canal Treatment in Necrotic Teeth Using Two Different Rotary Systems (Protaper Nex t& Neolix File)
NCT ID: NCT03059290
Last Updated: 2017-02-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
50 participants
INTERVENTIONAL
2017-03-01
2017-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison Between Reciproc and Protaper Next
NCT02946099
Postoperative Pain Following Treatment of Asymptomatic Necrotic Mandibular Molars in Single Visit Using Wave-one Reciprocating Instruments Versus One-Shape Rotary Instruments
NCT03301259
Pain Following One-visit Versus Two-visit Root Canal of Necrotic Teeth Using Protaper Next
NCT02984488
Post Operative Pain of Root Canal Preparation With Wave One and Neolix in Acute Irreversible Pulpitis
NCT02952300
Post-operative Pain After Laser Root Canal Treatment of Necrotic Teeth With Apical Periodontitis
NCT06129643
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Using neolix file (Ori kam SAS,France)
Control:
Using Protaper next files (Dentsply ,Maillefer , Switzerland)
Treatment in all cases will be completed in one session as follows:
* Full medical and dental history using a schematic dental chart will be obtained from all patients treated during this study. Each tooth will be evaluated for vitality (sensitivity) of pulp tissues using electric pulp tester (Kerr, Analytic Technology Crop, Redmond, WA).
* Patient will be anesthetized; teeth will be isolated with rubber dam.
* Make access and working length will be determined using an electronic apex locator (Root ZX, J.Morita USA, Irvine, CA.) then confirmed with intraoral periapical radiograph, to be 0.5-1 mm, shorter than radiographic apex.
* Cleaning and shaping will be done using crown down preparation technique with rotary files either
1. neolix file , first file used is C1 file size 25 taper 12% as orifice opener and for coronal flaring for 2/3 of canal length the A1 file size 25 taper 8% in narrow or curved canals if size 10 K file (Mani ,Japan ) is loose or pass easily in the canal , but in case of K-file size 20 loose in the canal so we choose large file size 40 taper 4% either of them to the full working length to the full working length with (X-Smart, Dentsply Maillefer, USA.), with speed 300-500 rpm and torque 1.5 N.cm or
2. protaper next in sequences by using Prepare straight line access to canal orifice. The ProTaper SX file may be used. Explore the canal using small-sized hand files, determine working length, verify patency and confirm a smooth, reproducible glide path. Always irrigate and if necessary, expand the glide path using small-sized hand files or dedicated mechanical glide path files. Path Files P1 and P2 are recommended. In the presence of NaOCl, brush and follow the glide path, with the PROTAPER NEXT™ X1 (017/04) file, in one or more passes until the working length is reached. Use PROTAPER NEXT X2 (025/06), exactly as described for PROTAPER NEXT X1 file, until the working length is passively reached. Gauge the foramen with a size 025 hand file and, if this file binds at length, the canal is shaped and ready for disinfection. If the size 025 hand file is loose at length, then continue shaping with the PROTAPER NEXT X3 (30/07) and, when necessary, the PROTAPER NEXT X4 (040/06) or PROTAPER NEXT X5 (050/06), gauging after each instrument with the 030, 040 or 050 hand files, respectively. During canal shaping, irrigate, recapitulate with a small-sized hand file after each sequential PROTAPER NEXT instrument, then re-irrigate. in an endodontic motor according to the manufacturer instructions (X-Smart, Dentsply Maillefer, USA.), with torque 2.0 N.cm and speed 300 rpm.
* The rotary files will be introduced inside the canal using EDTA gel "MD-Chelcream, META BIOMED CO.,LTD, Korea".
* The canals will be thoroughly irrigated using 3 ml of 2.5% Sodium hypochlorite between every subsequent instrument. After instrumentation of the canals, paper points will be used for drying.
* Obturation will be carried out using gutta percha cones (25/0.6 or 40/0.4) Or Protaper next cones according to instrument used and canal size with resin sealer (ADSEAL, META BIOMED CO., LTD,Korea).After obturation a cotton pellet will be placed in the pulp chamber and the access cavity will be closed with a temporary filling to avoid coronal leakage. ((MD-Temp, META BIOMED CO., LTD, Korea).
* The patient is given a Numerical Rating Scale and asked to rate his pain level at 6, 12, 24 \& 48 hours after obturation.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
SINGLE_GROUP
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
protaper next file
the PROTAPER NEXT™ X1 (017/04) file, in one or more passes until the working length is reached. Use PROTAPER NEXT X2 (025/06), exactly as described for PROTAPER NEXT X1 file, until the working length is passively reached. Gauge the foramen with a size 025 hand file and, if this file binds at length, the canal is shaped and ready for disinfection. If the size 025 hand file is loose at length, then continue shaping with the PROTAPER NEXT X3 (30/07) and, when necessary, the PROTAPER NEXT X4 (040/06) or PROTAPER NEXT X5 (050/06), gauging after each instrument with the 030, 040 or 050 hand files, respectively. During canal shaping, irrigate, recapitulate with a small-sized hand file after each sequential PROTAPER NEXT instrument, then re-irrigate. in an endodontic motor according to the manufacturer instructions (X-Smart, Dentsply Maillefer, USA.), with torque 2.0 N.cm and speed 300 rpm.
neolix file
first file used is C1 file size 25 taper 12% as orifice opener and for coronal flaring for 2/3 of canal length the A1 file size 25 taper 8% in narrow or curved canals if size 10 K file (Mani ,Japan ) is loose or pass easily in the canal , but in case of K-file size 20 loose in the canal so we choose large file size 40 taper 4% either of them to the full working length to the full working length with (X-Smart, Dentsply Maillefer, USA.), with speed 300-500 rpm and torque 1.5 N.cm
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
neolix file
first file used is C1 file size 25 taper 12% as orifice opener and for coronal flaring for 2/3 of canal length the A1 file size 25 taper 8% in narrow or curved canals if size 10 K file (Mani ,Japan ) is loose or pass easily in the canal , but in case of K-file size 20 loose in the canal so we choose large file size 40 taper 4% either of them to the full working length to the full working length with (X-Smart, Dentsply Maillefer, USA.), with speed 300-500 rpm and torque 1.5 N.cm
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient's age (20-65) years old.
* Upper \&lower anterior and premolar teeth diagnosed clinically as necrotic teeth.
* Positive patient's acceptance for participation in the study.
* Sex includes both male and female.
* Patients who can understand Numerical Rating Scale.
* Patients able to sign informed consent.
Exclusion Criteria
* Medically compromised patients.
* Patient with multiple teeth that required treatment to eliminate the possibility of pain referral.
20 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cairo University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
karim ahmed abdallah el nahas
master candidate at endodontic department faculty of oral and dental medicine CU
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
nehal nabil, assistant professor
Role: STUDY_CHAIR
faculty of oral and dental medicine - cairo university
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CEBC-CE-2017-01-15
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.