Bio Electrical Impedance Analysis to Monitor Fluid Status During Deresuscitation Strategy in Continuous Renal Replacement Therapy

NCT ID: NCT05160467

Last Updated: 2022-01-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

23 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-03-15

Study Completion Date

2022-01-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Fluid overload is a poor prognostic factor in patients undergoing continuous renal replacement therapy in critical care. A strategy of active fluid removal by net ultrafiltration (UFnet) is one of the means to correct it. However, fluid overload is difficult to quantify: weight variations or cumulative fluid balance are easy to use but imprecise and not concordant markers, while reference methods such as isotope dilution are not adapted to daily practice.

Bio electrical impedance analysis (BIA) is used to estimate body composition, including hydration. It is a non-invasive, rapid and painless measurement. It is commonly used in chronic intermittent haemodialysis to estimate dry weight and guide fluid removal, with a demonstrated impact on blood pressure control. This analysis is feasible in the ICU. Fluid overload as defined by BIA correlates with mortality, most notably in acute renal failure and during continuous renal replacement therapy.

We routinely perform multifrequency segmental BIA (InBody S10, Seoul, Korea) in patients with fluid overload in our intensive care department. Since February 2021, we have implemented a protocol to systematically correct fluid overload by inducing negative fluid balance with UFnet in a manner appropriate to tissue perfusion. In this context, we systematically perform a BIA analysis on the day of the beginning of the fluid balance negativation and then every 48 hours during the first five days.

We would like to evaluate the relevance of BIA monitoring in these patients by comparing it to other parameters of evaluation of the volume status usually used.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Fluid Overload

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Deresuscitation cohort

Patients with fluid overload (defined by a cumulative fluid balance \> 5%), stable hemodynamic (defined by Norepinephrine equivalent \< 0.5µg/kg/min and nor clinical nor biological sign of hypoperfusion) and continuous renal replacement therapy. All these patients benefit in our service from a protocol directed, perfusion based deresuscitation strategy with a 2mL/kg/h net ultra filtration to induce negative fluid balance and correct fluid overload. If hypoperfusion occurs, the net ultra filtration is stopped; if pulmonary oedema or right ventricular dysfunction occurs, the net ultra filtration is set to 3mL/kg/h.

We carried out at day 0, 1,3 and 5 bio electrical impedance analysis with an eight polar multifrequency bio impedance monitor (InBody S10), and monitor cumulative fluid balance with our prescription software and daily weight assessment.

Segmental multi-frequency bio electrical impedance analysis

Intervention Type DIAGNOSTIC_TEST

A segmental (eight-polar) multi-frequency bio electrical impedance analysis (Inbody S10, Seoul, Korea) is carried out at the initiation of the deresuscitation strategy, at day 1, 3 and 5, in lying posture with touch type electrodes. Raw and derived parameters are recorded. The measurement is performed 5 times for the first measurement and then one time at day 1, 3 and 5.

Measurement error is defined by the manufacturer as: reversed Impedance in different segment all between 5-500kHz; impedance over 50Ω in trunk, or over 700Ω in limb; sudden drop of impedance in trunk (more than 10Ω), or in limb (more than 50Ω). If it occurs, measurement is carried out three times maximum after solving potential technical issues to obtain a valid analysis.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Segmental multi-frequency bio electrical impedance analysis

A segmental (eight-polar) multi-frequency bio electrical impedance analysis (Inbody S10, Seoul, Korea) is carried out at the initiation of the deresuscitation strategy, at day 1, 3 and 5, in lying posture with touch type electrodes. Raw and derived parameters are recorded. The measurement is performed 5 times for the first measurement and then one time at day 1, 3 and 5.

Measurement error is defined by the manufacturer as: reversed Impedance in different segment all between 5-500kHz; impedance over 50Ω in trunk, or over 700Ω in limb; sudden drop of impedance in trunk (more than 10Ω), or in limb (more than 50Ω). If it occurs, measurement is carried out three times maximum after solving potential technical issues to obtain a valid analysis.

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age higher than 18
* Protocol directed deresucitation strategy with net ultrafiltration during continuous renal replacement therapy
* Bioelectrical impedance analysis available for the day of the initiation of the deresuscitation strategy and at day 5" -\> "At least two bioelectrical impedance analysis available during the first 5 days of the initiation of the deresuscitation strategy".

Exclusion Criteria

* Left ventricular assist device
* Patient opposition to the use of his health data
* Invalid bioelectrical impedance analysis
* Advanced directives to withhold or withdraw life-sustaining treatment
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Hospices Civils de Lyon

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Hôpital cardiologique Louis Pradel Groupe Hospitalier Est

Bron, , France

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

France

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Martin RUSTE, Dr

Role: CONTACT

+33472118956

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Martin RUSTE, M.D Msc

Role: primary

+33472118956

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

532

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Non-invasive Fluid Management
NCT02892799 UNKNOWN NA