Low Intensity Focused Ultrasound Pulses (LIFUP) to Modulate Pain

NCT ID: NCT04339972

Last Updated: 2021-08-19

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

29 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-02-01

Study Completion Date

2021-07-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The anterior nuclei of the thalamus in addition to periaqueductal gray (PAG) and rostral ventromedial medulla (RVM) are integral regions of a supraspinal opioidergic structure that regulate pain perception. With the capability to influence deep neurological tissues, low intensity frequency ultrasound pulsation (LIFUP) can likely modulate this circuit and induce analgesia. LIFUP deep brain modulation is achieved by induction of focused mechanical waveforms that traverse the cranium and underlying brain tissue. The low frequency of the ultrasonic wave consequently alters neuronal transmission and causes action potential variations through mechanical means, rather than thermal.

The purpose of this study is to examine whether stimulation of the anterior nuclei of the thalamus via LIFUP induces analgesia. We hypothesize that suppression of the anterior nuclei of the thalamus will induce a temporary increase in pain tolerance. Moreover, the behavioral changes in pain will correlate with specific regional BOLD changes during pain.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

LIFUP uses a single large concave, or multiple ultrasound transducers in a cap placed on the scalp to produce high frequency (100Hz) sonications for 30 seconds at a time for 10 trains of pulses. Unlike traditional diagnostic ultrasound, which constantly transmits ultrasound and 'listens' to the echo to form an image, LIFUP delivers the ultrasound in packets or pulses. For reasons that are not clear, pulsed ultrasound causes neurons to depolarize and fire. Bones typically block ultrasound waves. Cleverly, however, one can deliver the ultrasound from multiple sources and use the skull as a lens, to actually shape and focus the convergent beam deeper in the brain.

The clinical use of LIFUP thus uses MRI scans taken before stimulation to position and calculate how multiple ultrasonic pulsations will converge at a location in the brain (taking into account the bone dispersion of the beam from the skull). Since a small transducer like in diagnostic ultrasound cannot individually cause neuronal discharge, with LIFUP neuronal firing can be focused both deep (2-12cm under the cap; for comparison, traditional TMS can stimulate 1-3.4cm2 deep(9, 10)) and focally (as small as 0.5mm in diameter, and up to 1000mm; the facility of a standard, commercially-available 70mm figure-of-8 TMS coil is roughly 50mm2; (9, 10)). Interestingly, the pulse width of the carrying frequency of LIFUP (0.5ms) is strikingly similar to that used in all other pulsed neuromodulation therapies (DBS: 0.6ms, ECT: 0.5ms; TMS: 0.2ms; VNS: 0.5ms), suggesting that this timeframe is mechanistically meaningful. This is a good example of the common background science of brain stimulation that transcends the individual methods.

Researchers have examined the effects of LIFUP in preclinical and clinical settings, confirming its ability to safely stimulate neural tissue(11-14), proposing cellular mechanisms for its efficacy(13-19), and now using LIFUP in human patients(20). Monti et al. (2016) described a case study in which they used LIFUP to stimulate a comatose patient's thalamus.(20). Two pre-LIFUP assessments rated the patient as being in minimally conscious state (MCS). After sonication, the patient recovered motor and oromotor functions the next day, advancing to full language comprehension and communication by nodding and shaking his head. Five days post-LIFUP, the patient attempted to walk. While this study was neither blinded nor sham-controlled, the first application of therapeutic LIFUP in a human patient was encouraging and we expect more therapeutic applications of LIFUP and potential clinical trials in the future. If LIFUP continues to show clinical potential, it has the potential to supplant the role of DBS without the need for surgery. The key barrier to LIFUP replacing DBS for clinical applications is that by and large, DBS is used in a manner where the device is inserted and turned constantly on without attempting to fundamentally change circuit dynamics or behavior so that you could remove the device. Obviously, patients cannot permanently wear a LIFUP helmet. However, to the degree that we learn how to stimulate in ways that permanently change circuit behavior (LTD or LTP) without ablation, we may be able to substitute several sessions of LIFUP that can train and rewire the brain instead of permanently implanting hardware. LIFUP can certainly stimulate deep and focal and noninvasively and thus may be a key next step in the field of brain stimulation.

Information on the intervention to be studied. We will be using the Brainsonix Low intensity focused ultrasound pulsation device. (BX Pulsar 1001). Please see the manufacturers description (Technical Summary) along with appendixes about the actual safety of the device itself.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Healthy Adults

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

QUADRUPLE

Participants Caregivers Investigators Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Active LIFUP then Sham LIFUP

Real LIFUP is delivered to the participant for visit 1, followed by sham lifup visit 2

Group Type EXPERIMENTAL

LIFUP

Intervention Type DEVICE

Low Intensity Focused Ultrasound Pulsation (LIFUP) is an interesting new form of brain stimulation that may be possible to stimulate non-invasively, safely, deep in the brain with focal precision.

Sham LIFUP then Active LIFUP

Sham LIFUP is delivered to the participant for visit 1, followed by real lifup visit 2

Group Type SHAM_COMPARATOR

Sham LIFUP

Intervention Type DEVICE

The same as LIFUP but the device is not turned on and the subject does not receive any ultrasound.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

LIFUP

Low Intensity Focused Ultrasound Pulsation (LIFUP) is an interesting new form of brain stimulation that may be possible to stimulate non-invasively, safely, deep in the brain with focal precision.

Intervention Type DEVICE

Sham LIFUP

The same as LIFUP but the device is not turned on and the subject does not receive any ultrasound.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 18-45 years of age
* Healthy volunteer

Exclusion Criteria

* seizure history (individual or family)
* history of depression
* hospitalizations or surgeries in the previous 6 months
* currently experiencing pain
* history of chronic pain
* metal implants or objects (e.g. pacemakers, metal plates, wires)
* pregnant
* alcohol dependence
* illicit drug use in the previous 6 months
* known allergy to capsaicin
* history of brain surgery or brain lesions
* history of loss of consciousness (greater than 15 min)
* on stimulants or medications that lower seizure threshold.
Minimum Eligible Age

18 Years

Maximum Eligible Age

45 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medical University of South Carolina

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Medical University of South Carolina

Charleston, South Carolina, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Pro00082376

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

LIFU for Chronic Pain
NCT06628180 ENROLLING_BY_INVITATION NA
tFUS to Enhance Alertness and Performance
NCT06461221 WITHDRAWN EARLY_PHASE1
LIFU for Anxiety Management
NCT05839847 ACTIVE_NOT_RECRUITING NA