Focused Ultrasound Neuromodulation for Treatment of Temporal Lobe Epilepsy
NCT ID: NCT03657056
Last Updated: 2023-03-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2022-01-31
2023-03-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Low-intensity Focused Ultrasound Pulsation (LIFUP) for Treatment of Temporal Lobe Epilepsy
NCT02151175
Low Intensity Focused Ultrasound Epilepsy: A Pilot Trial
NCT03868293
Ultrasound Stimulation for Patients in a Disorder of Consciousness
NCT06939348
A Safety, Tolerability, and Preliminary Efficacy of Low-intensity Focused Ultrasound Neuromodulation in Patients With Drug-resistant Epilepsy
NCT06388707
Imaging-Guided Low Intensity Focused Ultrasound (LIFU)
NCT05467085
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Focused ultrasound (FUS) is a promising new potential treatment, because it can target any region in the brain, regardless of depth, with high spatial specificity. FUS allows for the non-invasive delivery of acoustic energy to a well-localized and circumscribed brain region of a few millimeters in diameter, depositing mechanical or thermal energy. The possibility of transcranial application of FUS into deep brain areas has already been demonstrated by the strategic placement and operation of an array of multiple ultrasound transducers.
The ultrasound based BrainSonix device is a highly novel non-invasive alternative to direct stimulation. Capitalizing on non-invasive high-intensity focused ultrasound (HIFU), BrainSonix, using an animal model, found early evidence of selective suppression of regional neural activity in the brain. Importantly these effects were non-thermal and reversible. Further study is required to validate and characterize the degree of suppressive effects on epilepsy to ensure safe application in human subjects. Low Intensity Focused Ultrasound Pulsation (LIFUP) differs from HIFU because the intensities of ultrasound used are an order of magnitude lower than HIFU. Also, whereas ablative HIFU is administered continuously, LIFUP is administered in short pulses, which reduces energy deposition. The investigators' and others data have demonstrated that administration of ultrasound, as LIFUP, causes a significant, but reversible, neuromodulatory effect, while preventing the tissue from being thermally damaged.
Study Procedures
Visit 1 Assessment The initial assessment will be performed shortly after signing the consent form. The patient will meet with the clinician and baseline demographic information and general physical information will be collected. The patient will also undergo a psychiatric/neurological evaluation, including a neurological exam, and several neuropsychiatric questionnaires using the Brief Symptom Inventory (BSI) self-report, the Beck Depression Inventory (BDI) self-report, a neuropsychiatric battery of tests described in section 9.2.4 below, the Mini-International Neuropsychiatric Interview (MINI) and the Mini-Mental Status Assessment (MMSE). They will also be required to complete an Magnetic Resonance Imaging (MRI) screening questionnaire to detect the presence of any devices that might present a safety risk.
Visit 2 Treatment and Assessment At visit 2, the location of the epileptic focus will be determined based on previously performed studies as part of the individual's routine epilepsy evaluation. The location of the epileptic focus will be determined based on previously performed studies as part of the individual's routine epilepsy evaluation. Brain MRI, interictal electroencephalogram (EEG), ictal EEG, interictal positron emission tomography (PET), ictal PET, interictal single-photon emission computerized tomography (SPECT), ictal SPECT, interictal magnetoencephalography (MEG), ictal MEG, and magnetic resonance (MR) spectroscopy data may be available and utilized to determine each participant's epileptogenic zone.
LIFUP will be administered to the temporal region on the side to undergo surgery, within the focus producing seizures (as determined by the comprehensive epilepsy evaluation). LIFUP session will take place during the 7 days prior to the operation. See Section 8.2.1 for more details regarding the LIFUP Sonication procedure.
The subject's heart rate and blood pressure will be monitored during the procedure. Routine electrode electroencephalography (EEG) will be recorded immediately before and after the LIFUP sonication session. Recording will last approximately 60 minutes.
The same neurological exam and neuropsychiatric questionnaires using the Brief Symptom Inventory (BSI) self-report, the Beck Depression Inventory (BDI) self-report, and the neuropsychiatric battery of tests described above will be performed at Visit 2, as well. Testing will last approximately 2 hours.
LIFUP Sonication Procedure
Low-Intensity Focused Ultrasound Pulsation (LIFUP) sonications will be conducted using the LIFUP experimental device BX Pulsar 1002 produced by the Brainsonix Corporation. LIFUP will be administered to the temporal region on the side to undergo surgery, within the focus producing seizures (as determined by the comprehensive epilepsy evaluation). In addition the functional magnet resonance imaging (fMRI) recording will be done during the LIFUP to determine the target area of activity and to navigate the focus of the transducer to that area. The ultrasound will be focused on the highest activity area within the temporal lobe. Functional MRI of the brain will be obtained throughout the LIFUP session. Initially LIFUP will be administered below the minimum effective dose determined in previous animal experiments. Up to 8 sonications will be administered during the LIFUP session. The total dose of LIFUP is not to exceed 2 min. The total time within the MRI machine will be up to 90 minutes.
After the participant is fitted with the transducer they will be placed in the MRI machine and undergo a series of scans. After placing the transducer over the anterior tip of the temporal lobe the participant will undergo fMRI BOLD scans with LIFUP excitation: Tone Burst Duration = 2ms and Pulse Repetition Frequency = 250Hz) at four levels of intensity (720mW/cm2, 1440mW/cm2, 2880mW/cm2 and 5760mW/cm2). Before increasing the intensity, the transducer will be moved approximately 5mm posterior. The excitation scans will be analyzed immediately for evidence of BOLD activation. After the last excitation scan the LIFUP parameters will be changed to inhibitory parameters: Tone Burst Duration = 0.5ms and Pulse Repetition Frequency = 100Hz).
Surgical Resection and Histology After surgical resection of the anterior temporal lobe, histology will be performed on the resected tissue to look for evidence of tissue injury not characteristic of temporal lobe epilepsy or previously identified on the routine brain MRI.
Three Month Follow-up At three months the epilepsy surgeon will assess the healing of the surgical wounds and will conduct a Structural MR. The results will be reported back to the investigator.
Six Month Follow-up At six months the epilepsy surgeon will carry out a neurogical exam, and several neuropsychiatric questionnaires using the Brief Symptom Inventory (BSI) self-report, the Beck Depression Inventory (BDI) self-report, a neuropsychiatric battery of tests described in section 9.2.4 below, the MINI, and the Mini Mental Status Assessment.
Neuropsychiatric Battery of Tests The following battery of neuropsychiatric tests will be performed on the study subjects at one of the participant's standard clinical visits, as part of their standard clinical care and at visit 2 following the LIFUP sonication procedure. This battery of tests has been designed to not interfere with their standard clinical care. The Visit 2 scores will be compared to the Visit 1 (Baseline) scores to assess neuropsychiatric changes as a result of the LIFUP procedure.
Seizure Account Participants will be instructed to maintain a daily log of all seizures from the date of consenting until the date of the operation.
Heart Rate and Blood Pressure Monitoring The patient will be affixed with a heart rate monitor. A periodic blood pressure check will be performed if the heart rate increases more than 30% during or immediately after sonication. The investigators' lab has the capacity to measure those parameters in MRI. If the patient's blood pressure has also increased more than 10% then they will be withdrawn from the study.
EEG Monitoring Routine electrode electroencephalography (EEG) recorded immediately before and after the LIFUP sonication session. Recording will last approximately 60 minutes.
A 30-minute awake EEG using scalp electrodes placed according to the International 10-20 System of electrode placement will be performed immediately before and immediately after the LIFUP treatment.
Interim Safety Analysis The data will be analyzed after the first subject in order to determine subsequent treatment paradigm in the next 2 subjects. After the first participant, histology data will also be analyzed by the investigator. If the participant shows histological damage in the a category (i.e. apoptosis, irreversible blood brain barrier (BBB) disruption, ischemia) at a given intensity then the investigators will continue with the next cohort of 2 participants, but the investigators will no longer use that intensity, or higher intensities. If more than one participant shows histological damage in the same category at the lowest intensity (720mW/cm2), then the study will be stopped.
Biostatistical Analysis
Statistical analyses will be performed using SAS® v9.3 or higher (SAS Institute, Cary NC, USA).
All statistical analyses of safety and performance measures will be descriptive in nature. Continuous variables will be summarized by a mean, standard deviation, minimum, median and maximum, and categorical variables by a count and percentage. Confidence intervals will be provided where relevant.
If multiple evaluations are taken in a single patient, statistics described below will be appropriately modified to accommodate the within patient correlation.
Demographic, medical and clinical history variables will be tabulated. Continuous variables will be summarized by a mean, standard deviation, minimum, median and maximum, and categorical variables by a count and percentage.
The numbers of patients who were enrolled and completed each visit of the study will be provided, as well as the reasons for all enrollment discontinuations, grouped by major reason (e.g., lost to follow-up, adverse event). A list of discontinued patients, protocol deviations, and patients excluded from the efficacy analysis will be provided as well.
Histological results in the resected tissue of the anterior temporal lobe will be presented.
Comparison of all neurological assessment scores at the pre-treatment visit and at the post-treatment visit will be presented.
Comparison of the number of epileptiform discharges and Epileptiform Discharge frequency (DF) during a 30-minute period before and a 30-minute period after LIFUP will be presented.
Change in BOLD signal during or after LIFUP sonication will be presented.
Subjects who do not have valid data for the efficacy measures will be treated as missing values. No imputation is planned.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
Patients identified as candidates for temporal lobe surgery by the clinical team will be notified via a letter that has been signed by a physician representative of the practice of their eligibility for the study. An administrator will follow-up on the letter with a phone call. The physician of potential participants will be notified of their eligibility for the study, and be provided with a copy of the consent form. A total of 3 participants will be enrolled in the project.
DEVICE_FEASIBILITY
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
BX Pulsar 1002
Low-Intensity Focused Ultrasound Pulsation (LIFUP) sonications will be conducted using the LIFUP experimental device BX Pulsar 1002 produced by the Brainsonix Corporation. For the purposes of safety LIFUP sonications will be initiated at the FDA limit for diagnostic ultrasound. However, the minimally effective dose in humans applications, according to (Lee et al., 2015), when derated is approximately 1125mW/cm2.
BX Pulsar 1002
LIFUP will be administered to the temporal region on the side to undergo surgery, within the focus producing seizures. The ultrasound will be focused on the highest activity area within the temporal lobe. Functional MRI of the brain will be obtained throughout the LIFUP session.
After the participant is fitted with the transducer they will be placed in the MRI machine and undergo a series of scans. After placing the transducer over the anterior tip of the temporal lobe the participant will undergo fMRI BOLD scans with LIFUP excitation (from (Lee et al., 2015): Tone Burst Duration = 2ms and Pulse Repetition Frequency = 250Hz) at four levels of intensity (720mW/cm2, 1440mW/cm2, 2880mW/cm2 and 5760mW/cm2). Before increasing the intensity, the transducer will be moved approximately 5mm posterior. After the last excitation scan the LIFUP parameters will be changed to inhibitory parameters (from (Yoo et al., 2011): Tone Burst Duration = 0.5ms and Pulse Repetition Frequency = 100Hz).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
BX Pulsar 1002
LIFUP will be administered to the temporal region on the side to undergo surgery, within the focus producing seizures. The ultrasound will be focused on the highest activity area within the temporal lobe. Functional MRI of the brain will be obtained throughout the LIFUP session.
After the participant is fitted with the transducer they will be placed in the MRI machine and undergo a series of scans. After placing the transducer over the anterior tip of the temporal lobe the participant will undergo fMRI BOLD scans with LIFUP excitation (from (Lee et al., 2015): Tone Burst Duration = 2ms and Pulse Repetition Frequency = 250Hz) at four levels of intensity (720mW/cm2, 1440mW/cm2, 2880mW/cm2 and 5760mW/cm2). Before increasing the intensity, the transducer will be moved approximately 5mm posterior. After the last excitation scan the LIFUP parameters will be changed to inhibitory parameters (from (Yoo et al., 2011): Tone Burst Duration = 0.5ms and Pulse Repetition Frequency = 100Hz).
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subjects with clinical evidence from their diagnostic evaluations of unilateral hippocampal - dysfunction and epileptogenicity, confirmed via intracarotid amobarbital procedure (IAP) and neuropsychological testing.
* Subjects with seizures that have been refractory to treatment with at least three currently marketed antiepileptic drugs.
* Subjects currently taking antiepileptic medications.
* Subjects with at least 3 seizures/month based on seizure diary.
* Subjects with epilepsy who would clearly benefit from surgical intervention.
* Subjects who have been offered an anterior-mesial temporal lobe resection, performed en-bloc, as treatment for medication refractory epilepsy. This includes both dominant or non-dominant mesial temporal lobe focal epilepsy.
Exclusion Criteria
* Subjects with dementia, delirium and psychotic symptoms.
* Subjects with ferromagnetic materials in the head.
* Subjects with severe cardiac disease, increased intracranial pressure, or a transcutaneous electrical nerve stimulation (TENS) unit.
* Subjects who exhibit primary generalized seizures or pseudoseizures.
* Subjects who have seizures secondary to drugs, alcohol, metabolic illness or progressive degenerative disease.
* Subjects who have experienced status epilepticus during the 3-week period prior to the LIFUP procedure.
* Subjects (females) who are pregnant.
* Patients who have had electrodes implanted in the brain that were not explanted at least 6 weeks prior to the LIFUP procedure.
* Patients who have had electrodes implanted into the focal point of the temporal lobe that is proposed for the ultrasonic stimulation using LIFUP.
18 Years
60 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Massachusetts General Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Darin Dougherty, MD
Director, Division of Neurotherapeutics, Department of Psychiatry
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Darin Dougherty, MD
Role: PRINCIPAL_INVESTIGATOR
Massachusetts General Hospital
References
Explore related publications, articles, or registry entries linked to this study.
Hynynen K, Jolesz FA. Demonstration of potential noninvasive ultrasound brain therapy through an intact skull. Ultrasound Med Biol. 1998 Feb;24(2):275-83. doi: 10.1016/s0301-5629(97)00269-x.
Gavrilov LR, Tsirulnikov EM, Davies IA. Application of focused ultrasound for the stimulation of neural structures. Ultrasound Med Biol. 1996;22(2):179-92. doi: 10.1016/0301-5629(96)83782-3.
Tyler WJ, Tufail Y, Finsterwald M, Tauchmann ML, Olson EJ, Majestic C. Remote excitation of neuronal circuits using low-intensity, low-frequency ultrasound. PLoS One. 2008;3(10):e3511. doi: 10.1371/journal.pone.0003511. Epub 2008 Oct 29.
Min BK, Bystritsky A, Jung KI, Fischer K, Zhang Y, Maeng LS, Park SI, Chung YA, Jolesz FA, Yoo SS. Focused ultrasound-mediated suppression of chemically-induced acute epileptic EEG activity. BMC Neurosci. 2011 Mar 6;12:23. doi: 10.1186/1471-2202-12-23.
Yoo SS, Kim H, Min BK, Franck E, Park S. Transcranial focused ultrasound to the thalamus alters anesthesia time in rats. Neuroreport. 2011 Oct 26;22(15):783-7. doi: 10.1097/WNR.0b013e32834b2957.
Deffieux T, Younan Y, Wattiez N, Tanter M, Pouget P, Aubry JF. Low-intensity focused ultrasound modulates monkey visuomotor behavior. Curr Biol. 2013 Dec 2;23(23):2430-3. doi: 10.1016/j.cub.2013.10.029. Epub 2013 Nov 14.
Lee W, Kim H, Jung Y, Song IU, Chung YA, Yoo SS. Image-guided transcranial focused ultrasound stimulates human primary somatosensory cortex. Sci Rep. 2015 Mar 4;5:8743. doi: 10.1038/srep08743.
Legon W, Sato TF, Opitz A, Mueller J, Barbour A, Williams A, Tyler WJ. Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans. Nat Neurosci. 2014 Feb;17(2):322-9. doi: 10.1038/nn.3620. Epub 2014 Jan 12.
Mitchell LA, Jackson GD, Kalnins RM, Saling MM, Fitt GJ, Ashpole RD, Berkovic SF. Anterior temporal abnormality in temporal lobe epilepsy: a quantitative MRI and histopathologic study. Neurology. 1999 Jan 15;52(2):327-36. doi: 10.1212/wnl.52.2.327.
Vykhodtseva NI, Hynynen K, Damianou C. Histologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivo. Ultrasound Med Biol. 1995;21(7):969-79. doi: 10.1016/0301-5629(95)00038-s.
Vykhodtseva N, McDannold N, Martin H, Bronson RT, Hynynen K. Apoptosis in ultrasound-produced threshold lesions in the rabbit brain. Ultrasound Med Biol. 2001 Jan;27(1):111-7. doi: 10.1016/s0301-5629(00)00275-1.
Cohen MS, DuBois RM. Stability, repeatability, and the expression of signal magnitude in functional magnetic resonance imaging. J Magn Reson Imaging. 1999 Jul;10(1):33-40. doi: 10.1002/(sici)1522-2586(199907)10:13.0.co;2-n.
Smith SM, Jenkinson M, Woolrich MW, Beckmann CF, Behrens TE, Johansen-Berg H, Bannister PR, De Luca M, Drobnjak I, Flitney DE, Niazy RK, Saunders J, Vickers J, Zhang Y, De Stefano N, Brady JM, Matthews PM. Advances in functional and structural MR image analysis and implementation as FSL. Neuroimage. 2004;23 Suppl 1:S208-19. doi: 10.1016/j.neuroimage.2004.07.051.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2018P001352
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.