Tunnel Attachments With Clear Aligners vs Clear Aligners

NCT ID: NCT04130477

Last Updated: 2019-10-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

34 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-11-01

Study Completion Date

2021-05-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Incorporating wire threaded custom tunnel attachments with clear aligner therapy is a novel approach developed to address the shortcomings of the currently available orthodontic systems. This hybrid system is anticipated to take advantage of the benefits and overcome many of the limitations of traditional fixed buccal/lingual appliances and clear aligner therapy. The concept utilizes light arch wires to be threaded through computer designed, chairside-fabricated composite tunnel attachments to achieve better control of three-dimensional tooth movements not achievable by clear aligners, such as Invisalign® (Align Technology, Santa Clara, CA) alone. The superelastic feature of the arch wires allows delivery of more continuous forces than aligners alone, potentially permitting shorter duration of recommended aligner wear during orthodontic treatment. A virtual set-up would be used to plan the desired position of the teeth, which in turn will be used to customize the size and position of composite tunnel attachments based on how two round arch wires will pass through tubes within the attachments. The attachments can be placed on either the buccal or lingual surfaces of teeth, depending on clinical preferences and esthetic demands. This is achievable using in-house aligners, which will also allow the fabrication of aligners in the office or at a conventional orthodontic lab at a fraction of the cost of traditional clear aligners.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Specific aims:

* Test and formally describe a novel method that utilizes clear aligners paired with computer-designed, chairside-fabricated tunnel attachments to achieve tooth movements that are challenging for clear aligners.
* Conduct a randomized clinical trial to compare the ability of a traditional clear aligner system Invisalign® (Align Technology, Santa Clara, CA) and a clear aligner system incorporating wire threaded tunnel attachments in:

* achieving predicted outcomes; discrepancies in bucco-lingual and inciso-gingival positions between the virtual plan and end of treatment intraoral scan and will be measured in millimeters and angular discrepancies will be measured in degrees
* end of treatment ABO leveling and alignment objective grading scores

Materials and Methods:

A virtual set-up is completed by the clinician to plan the position, orientation, and dimension will be customized on the teeth to be moved.Generally, they are spherically shaped and their dimensions are approximately 2-3 mm. Vacuum-formed attachment template will be made to take the shape of a tube-holding spheres, in which tubes are embedded. The tubes are standard in size with an outside diameter of 0.032", and an inside diameter of 0.019" and 2 mm length The template will be loaded with composite after inserting the metal tubes are placed in their predetermined location on the tray. Double tubes will be used when torque control is needed. 0.016" buccal or lingual round wires will be placed into the tunnel attachments along the attachments. Aligners will be delivered to patient to be worn for at least 8 hours a day and changed as determined by the Dental Monitoring application.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Malocclusion

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Tunnel attachments as an auxiliary with clear aligners
Primary Study Purpose

TREATMENT

Blinding Strategy

TRIPLE

Caregivers Investigators Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Clear aligners with tunnel attachment

Participants will receive traditional clear aligner therapy with virtual set up and will be supplemented by virtually planned tunnel attachments which will be threaded by a light Nickel-Titanium wire

Group Type EXPERIMENTAL

Tunnel attachments and light Nickel Titanium wire

Intervention Type DEVICE

Tunnel attachments planned virtually and light Nickel Titanium wire

Clear aligners

Participants will receive traditional clear aligner therapy with virtual set up

Group Type ACTIVE_COMPARATOR

Clear Aligner therapy

Intervention Type DEVICE

Clear Aligner therapy

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tunnel attachments and light Nickel Titanium wire

Tunnel attachments planned virtually and light Nickel Titanium wire

Intervention Type DEVICE

Clear Aligner therapy

Clear Aligner therapy

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. healthy subjects over the age of 10 years and below 65;
2. eruption of all permanent anterior teeth;
3. non-extraction treatment;
4. maximum of 7mm of crowding/spacing;
5. no more than 45 degrees of rotations
6. no more than 7 mm crowding

Exclusion Criteria

1. presence of systemic diseases, cleft lip and palate, craniofacial anomalies, syndromes affecting bone or teeth, impacted teeth (excluding 3rd molars), congenitally missing lateral incisors, and tumors of the parathyroid gland;
2. the presence of bridges or implants replacing anterior teeth;
3. cases requiring orthognathic surgery;
4. significant (\> moderate) periodontal disease, intake of drugs affecting tooth movement or bone formation (chronic use of Non-Steroidal Anti-Inflammatory Drugs, bisphosphonates, levothyroxine, or teriparatide drug class), pregnancy;
5. cases requiring tooth extractions
Minimum Eligible Age

12 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Harvard School of Dental Medicine

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Alyaa Aldohan

Orthodontic resident and Doctor of Medical Sciences candidate

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Mohamed Masoud, BDS, DMSc

Role: PRINCIPAL_INVESTIGATOR

Harvard School of Dental Medicine

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Alyaa Aldohan, BDS

Role: CONTACT

8572658533

References

Explore related publications, articles, or registry entries linked to this study.

Papadimitriou A, Mousoulea S, Gkantidis N, Kloukos D. Clinical effectiveness of Invisalign(R) orthodontic treatment: a systematic review. Prog Orthod. 2018 Sep 28;19(1):37. doi: 10.1186/s40510-018-0235-z.

Reference Type RESULT