Accuracy of Selective Laser Sinteredcomputer Guided Stents Versus Digital Light Processing Stents
NCT ID: NCT03287934
Last Updated: 2020-07-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
22 participants
INTERVENTIONAL
2017-12-01
2020-02-11
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Efficacy of a Ready Made Plastic Stent With Apically Repositioned Flap in Augmentation of the Peri Implant Soft Tissue
NCT03754894
Patient Satisfaction ,Marginal Integrity ,Shade Matching and Gingival Health of Zirconia Reinforced Lithium Silicate Bridges Cemented Using Bioactive Cement and Adhesive Resin Cement
NCT03691597
Using of Injectable Platelet Rich Fibrin on Filling the Gap of Immediate Dental Implant
NCT04298294
Accuracy and Reproducibility of Virtually Guided Minimally Invasive Tooth Preparations Using Reverse Engineering
NCT04653519
Laser Biostimulation on Implant Covered With PRF in Controlled Diabetics
NCT06444334
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
* Diagnostic phase : for initial diagnosis, principle investigator will make primary impression , bite registration, face bow record and periapical x-ray for each eligible patients. The tooth to be extracted will be removed from the cast and replaced with an artificial tooth. For construction of radio graphic stent, a clear thermoplastic sheet will be pressed on the modified cast using a vacuum forming machine . A hole is done in the center of the artificial tooth packed with heated gutta percha (radiopaque material) for easy visualization on the cone beam during virtual implant placing. A dual scan protocol with cone beam CT will be made. The first scan is for the patient wearing the scan appliance while the second will be for the cast with the scan appliance.
* Planning phase : placing of the virtual implant and designing of the surgical stent will be done by virtual planning software .
* Construction of the surgical guide: principle investigator will send the Standard Language transformation (STL) file of the designed guide to a rapid prototyping center. Selective laser sintering and digital light procesing will be used for intervention and control group respectively. principle investigator will check for adaption of the guide on the cast and cement the metallic sleeve to prevent rotation during surgery.
* Surgical phase : principle investigator will prescribe a prophylactic antibiotic to the patient three days prior the surgery. Atraumatic extraction will be carried by periotomes and lancet. The integrity of the socket will be examined well by probe. The guide is stabilized in its place then drilling and implant placement will be done. Healing abutment is screwed in place to allow proper healing of the soft tissue. Patient will be instructed to avoid hard foods and follow restrict oral hygiene measures. Patient will be recalled after one week for postoperative inspection and assessment. A cone beam CT will be taken for deviation assessment.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
digital light processing stent
according to the allocation, the experimental group will receive a digital light processing stent for immediate implant drilling and placement after atraumatic extraction of the target tooth.
selective laser sintered stent
after planning and virtual implant placement, a guide will be designed and the STL file will be send to prototyping center for printing the guide with selective laser sintering technique. during the surgical procedure , the target tooth will be atraumatic extracted, the stent is adapted in its place then implant drilling and placement will be done.
digital light processing(dlp)
after planning and virtual implant placement, a guide will be designed and the STL file will be send to prototyping center for printing the guide with digital light processing technique. during the surgical procedure , the target tooth will be atraumatic extracted, the stent is adapted in its place then implant drilling and placement will be done.
selective laser sintering
according to the allocation, the intervention for the control group will be a selective laser sintering stent after atraumatic extraction of the target tooth for immediately implant placement. the selective laser sintering stent will be adapted and drilling will be done through the stent.
selective laser sintered stent
after planning and virtual implant placement, a guide will be designed and the STL file will be send to prototyping center for printing the guide with selective laser sintering technique. during the surgical procedure , the target tooth will be atraumatic extracted, the stent is adapted in its place then implant drilling and placement will be done.
digital light processing(dlp)
after planning and virtual implant placement, a guide will be designed and the STL file will be send to prototyping center for printing the guide with digital light processing technique. during the surgical procedure , the target tooth will be atraumatic extracted, the stent is adapted in its place then implant drilling and placement will be done.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
selective laser sintered stent
after planning and virtual implant placement, a guide will be designed and the STL file will be send to prototyping center for printing the guide with selective laser sintering technique. during the surgical procedure , the target tooth will be atraumatic extracted, the stent is adapted in its place then implant drilling and placement will be done.
digital light processing(dlp)
after planning and virtual implant placement, a guide will be designed and the STL file will be send to prototyping center for printing the guide with digital light processing technique. during the surgical procedure , the target tooth will be atraumatic extracted, the stent is adapted in its place then implant drilling and placement will be done.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Hopeless tooth in esthetic zone due to caries, endodontical problem or trauma with both neighboring teeth present.
3. Good oral hygiene
4. No periapical lesions (acute accesses or chronic fistula)
5. Adequate bone (5 mm) below the tooth to allow primary implant stability
6. Sufficient Medio-distal bone about 1.5 from each side
7. sufficient labial bone
8. sufficient band of keratinized mucosa
Exclusion Criteria
2. any systemic condition that is considered absolute contraindication for implant placement
3. pregnancy
4. in adequate inter-arch space
5. parafunctional habits as bruxism
18 Years
50 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cairo University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
mahetab hamdi
principal investigator
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Faculty of Dentistry Cairo University
Cairo, Manil, Egypt
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Abduo, J., Lyons, K. & Bennamoun, M., 2014. Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams. International Journal of Dentistry, 2014, pp.1-15. Available at: http://www.hindawi.com/journals/ijd/2014/783948/. Alzoubi, Fawaz, Nima Massoomi, and A.N., 2016. Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides. Journal of Oral Implantology ., 42(5), pp.391-398. Arısan, V. et al., 2013. Implant Positioning Errors in Freehand and Computer-Aided Placement Methods: A Single-Blind Clinical Comparative Study. The International Journal of Oral & Maxillofacial Implants, 28(1), pp.190-204. Available at: http://www.quintpub.com/journals/find_article.php?doi=10.11607/jomi.2691.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
R.prosthodontic department
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.