NoL, HR and MABP Responses to Tracheal Intubation Performed With MAC Blade Versus Glidescope
NCT ID: NCT03277872
Last Updated: 2021-10-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
50 participants
INTERVENTIONAL
2017-09-05
2021-07-02
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
* To observe if the alterations of the NoL index and the standard monitoring (Mean Arterial Blood Pressure and Heart Rate) (using the variability of NoL index and standard monitoring, peak NoL index and peak standard monitoring values, and number of time passed over their respective threshold for nociceptive response) are more accentuated after laryngoscopy using the classical MAC blade versus single-use disposable blade of the Glidescope.
* To observe the nociceptive response (using the variability of NoL index and standard monitoring, peak NoL index and peak standard monitoring values, and number of time passed over their respective threshold for nociceptive response) related to the insertion of endotracheal tube between vocal cords during the intubation.
Study plans to enroll 50 adult patients scheduled to undergo either general, gynecological, neurological, orthopedic, plastic or urological surgery under general anesthesia and who necessitate endotracheal intubation.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Macintosh Versus GlideScope Versus C-MAC for Double Lumen Endotracheal Intubation
NCT05091281
Comparison of Conventional GlideScope to Single-Use GlideScope Cobalt for Orotracheal Intubation
NCT00459797
Comparison of the Glidescope and Macintosh Laryngoscope for Double Lumen Endotracheal Tube Intubation
NCT01404780
Out-of-Hospital Intubation With Metal Single Use Laryngoscope Blades
NCT00644722
Does McGRATH® MAC Videolaryngoscope Decrease the Number of People Required to Perform Intubation During Anesthesia ?
NCT02926144
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In this prospective, randomized and controlled study, each patient will normally enter the operating room on the day of his surgery. All the normal monitors are installed, along with the NoL monitor. Pre-oxygenation (with 100% 02) is then started. While the patient is doing the pre-oxygenation, MABP, HR and NoL index measures are gathered to establish a baseline for each patient.
Once pre-oxygenation is over, induction with xylocaïne, propofol, remifentanil and rocuronium is given (according to patients' ideal weight). The end of the remifentanil bolus will correspond to the time 0 of our study. To be sure our patients are sleeping and on the same level of anesthetic medication during our study, perfusions of propofol and remifentanil will be administred until tracheal intubation and inhaled anesthetic gaz given. When the patient is asleep and apneic, a Guedel device (chosen according to patient weight and height) is inserted in the mouth, as in usual practice, to ease the manual ventilation until the laryngoscopy. The patient is then ventilated with a face mask. After 5 minutes, the first laryngoscopy is performed (either with GlideScope blade or MAC blade according to randomization). Once a Cormack-Lehane grade I or II is obtained, the movement is ended, and the patient is ventilated again for 4 minutes with the Guedel. If the procedure takes more than 30 seconds to perform (if no view of grade I or II is seen before 30 seconds), the laryngoscopy is considered difficult and the patient will be excluded from the study. At T9 (9 minutes after T0), the second laryngoscopy is done (either with the MacIntosh blade or the GVL blade - the tool used for the second laryngoscopy will always be the one that wasn't used at the first laryngoscopy). The size of the MacIntosh blade (MAC 3 or 4) or the disposable blade for GVL is decided according to the patient size (height and weight). At the second laryngoscopy, the endotracheal tube is still not inserted, only the procedure of laryngoscopy is done, so that we can evaluate the hemodynamic and the NoL index responses related only to the type of device used for laryngoscopy. Then, the operator replaces the Guedel and ventilates the patient with a facemask (100% O2) for 4 more minutes, without stimulating the patient otherwise. At T13 (13 minutes after T0), the third laryngoscopy will be performed (either with the single-use blade for GlideScope or the MacIntosh blade - according to randomization). This time, the ETT is inserted (size 7 or 8, depending on the size and sex of the patient). After ETT insertion, the patient is then ventilated with the anesthesia machine and the perfusions of propofol/remifentanil is discontinued.
Monitors will record HR, MABP and NoL index until 3 minutes after the ETT insertion (end of the study). All the data will be electronically registered every 5 seconds and exported in an anonymous manner for each patient into an excel file at the end of the study.
In this study, each patient is exposed to three laryngoscopies; one with the single use blade for the GlideScope, one with the Macintosh laryngoscopy and one with the ETT insertion (laryngoscopy done with either GlideScope or Macintosh according to randomization). Hence, each patient will be its own control. It will then be more reliable to compare the differences in nociceptive response according to the tool used for laryngoscopy.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
This will lead to 2 different groups for the first randomization process regarding our primary objective:
* GVL / MAC-DL / GVL or MAC-DL+ETT,
* MAC-DL / GVL / GVL or MAC-DL+ETT.
The tool used for the third laryngoscopy will be decided according to a second randomization, necessary to one of our secondary objectives.
Each patient will be its own control when comparing nociceptive response to different laryngoscopy/intubation tool (no need for control group).
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
GlideScope (GVL) Blade
Patients in this arm will have the first laryngoscopy performed with the GlideScope (GVL) blade and the second one with the MacIntosh blade. The tool used for the third laryngoscopy, followed by intubation, (either GlideScope or MAC blade) will be decided according to a second randomization, necessary to one of our secondary objectives.
Laryngoscopy with GlideScope (GVL) Blade
1. st Laryngoscopy with GVL Blade
2. nd Laryngoscopy with MAC Blade
3. rd Laryngoscopy and ETT insertion with either GVL or MAC Blade according to 2nd randomization
MacIntosh (MAC) Blade
Patients in this arm will have the first laryngoscopy performed with the MacIntosh (MAC) blade and the second one with the GlideScope blade. The tool used for the third laryngoscopy, followed by intubation, (either GlideScope or MAC blade) will be decided according to a second randomization, necessary to one of our secondary objectives.
Laryngoscopy with MacIntosh (MAC) Blade
1. st Laryngoscopy with MAC Blade
2. nd Laryngoscopy with GVL Blade
3. rd Laryngoscopy and ETT insertion with either GVL or MAC Blade according to 2nd randomization
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Laryngoscopy with GlideScope (GVL) Blade
1. st Laryngoscopy with GVL Blade
2. nd Laryngoscopy with MAC Blade
3. rd Laryngoscopy and ETT insertion with either GVL or MAC Blade according to 2nd randomization
Laryngoscopy with MacIntosh (MAC) Blade
1. st Laryngoscopy with MAC Blade
2. nd Laryngoscopy with GVL Blade
3. rd Laryngoscopy and ETT insertion with either GVL or MAC Blade according to 2nd randomization
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Mallampati class I or II
* Patients \> 18 years old
* Elective general, gynecological, neurological, orthopedic, plastic or urological surgery under general anesthesia
* Type of surgery that usually necessitate endotracheal intubation and controlled ventilation
Non-inlusion Criteria:
* Patient refusal
* History of psychiatric diseases or psychological problems (including mental retardation); inability to give consent; language barrier.
* Anticipated difficult airway (Mallampati class III and IV, thyromental distance \< 6 cm, mouth opening \< 3 cm, neck extension \<80° and neck flexion \<35°, inability to prognath, meaning bringing lower mandibular before the upper maxilla)
* Patient with history of neck rigidity or instability
* BMI \> 30
* Patient with beard (because of recognized risk for difficult ventilation)
* Patient with history of oropharyngeal or tracheal surgery (excluding adenoidectomy, amygdalectomy and teeth removal)
* Severe coronary artery disease
* Serious cardiac arrhythmias (including atrial fibrillation)
* Use of β-blockers (all types)
* History of opioid or illicit drug substance abuse
* Chronic use of psychotropic and/or opioid drugs
* Allergy to remifentanil or propofol
* Pregnancy
* Contraindications to mask ventilation (GI tract obstruction, pregnancy, active GERD, non-fasting patients)
* Difficult mask ventilation (before randomization at the first laryngoscopy)
Exclusion Criteria
* Requiring hemodynamic support with vasopressors or inotropes 5 minutes before first laryngoscopy to 3 minutes after insertion of ETT
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Verathon
INDUSTRY
Canadian Hospital Specialties Ltd
UNKNOWN
Ciusss de L'Est de l'Île de Montréal
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Philippe Richebe
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Philippe Richebe, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
Université de Montréal
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hopital Maisonneuve Rosemont, CIUSSS de l'Est de l'Ile de Montreal
Montreal East, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Sbeghen V, Verdonck O, McDevitt J, Zaphiratos V, Brulotte V, Loubert C, Tanoubi I, Drolet P, Belanger ME, Fortier LP, Godin N, Guertin MC, Fortier A, Richebe P. A randomized controlled trial comparing nociception level (NOL) index, blood pressure, and heart rate responses to direct laryngoscopy versus videolaryngoscopy for intubation: the NOLint project. Can J Anaesth. 2021 Jun;68(6):855-867. doi: 10.1007/s12630-021-01936-0. Epub 2021 Mar 11.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2018-1144
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.