Diagnostic Value of Passive Leg Raise Induced Changes in Carotid Artery Flow Time to Predict Fluid Responsiveness in Critically Ill Patients
NCT ID: NCT02789124
Last Updated: 2016-06-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
22 participants
INTERVENTIONAL
2014-06-30
2015-11-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of Corrected Carotid Flow Time Variations During Passive Leg Lift to Predict Response to Filling.
NCT04732481
Corrected Flow Time in the Carotid Artery as a Predictor of Fluid Responsiveness in Mechanically Ventilated Patients With Low Tidal Volume in the Intensive Care Unit
NCT04139031
Ultrasound Assessment of Changes in the Diameter of the Common Carotid Artery After Increasing the Preload of the Heart
NCT03412422
Can Capillary Refill Time Variation During Passive Leg Raising Predict Fluid Responsiveness
NCT02248025
Passive Leg Raise Induced Stroke Volume Changes in Elderly Prior to Elective Surgery Measured by LiDCOplusTM
NCT02977390
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Only approximately 50% of ICU patients have been shown to respond to volume expansion in studies designed to examine fluid responsiveness.9 Ideally, Intensivists would have access to a cheap, reliable, continuously operating, non-invasive, and user friendly device so that fluid could be administered until their patient is no longer fluid responsive. Stroke volume could be maximized via the Frank-Starling relationship and over resuscitation with its potential deleterious effects could be avoided. Although measurement of thermodilution cardiac output by the Pulmonary Artery Catheter (PAC) is considered the "gold standard" by which new devices are validated, it has a waning role in modern ICUs. Existing technologies such as Esophageal Doppler, Transpulmonary Indicator Dilution, and Arterial-Pressure-Waveform-Derived methods, while not as invasive as a PAC, are still invasive procedures. Echocardiography is an excellent tool, however assessing for fluid responsiveness requires advanced training beyond a qualitative approach and it can be difficult to obtain optimal windows in critically ill patients. Thus, current methods for assessment of fluid responsiveness are suboptimal.
The use of Carotid Doppler to determine volume responsiveness has recently been proposed. Remarkably, the authors found that an increase in carotid blood flow of 20% predicted fluid responsiveness with a sensitivity of 94% and specificity of 86%. This appears to be an attractive option, with the caveats that not all point of care ultrasound machines currently available have the software capability to calculate carotid artery velocity time integral (VTI) and this method was validated using Bioreactance, the reliability of which has been recently questioned. A more simple method of evaluating the carotid artery for fluid responsiveness, the Carotid Flow Time, was recently discussed on a popular ultrasound podcast, but has not yet been validated in a clinical study.
The Carotid Artery Corrected Flow Time (FTC) concept is not new. In fact, it has been well studied as a marker of preload and afterload with Transesophageal Doppler (TED). TED monitors display a wave form of the velocity versus time similar to the image one might obtain doing pulsed wave Doppler (PWD) of the carotid artery. With TED, the waveform has a triangular appearance. The apex of the triangle represents peak velocity, which along with mean acceleration reflects cardiac contractility. The area under the systolic portion of the curve is equal to stroke distance, and when multiplied by the cross sectional area of the descending aorta this value can be used to estimate cardiac output predicated on the assumption that the descending aorta receives 70% of cardiac output. The investigators are interested in the base of the triangle representing systolic ejection time. When corrected for heart rate by dividing by the square root of cardiac cycle time we have the FTC. The FTC would be expected to increase with enhanced preload or reduction in afterload; conversely it should decrease with a reduction in preload or increase in afterload. One study performed in 20 neurosurgical patients with TED showed that the FTC was able to predict fluid responsiveness when used as a static measure with a cutoff of 357 ms prior to loading with 7 ml/kg of hydroxyethyl starch solution. The area under the receiver operating curve (ROC) was 0.944.
The investigators believe that the concept of FTC as a marker of preload can be combined conveniently with PWD of the carotid artery and a passive leg raising maneuver (PLR) to estimate fluid responsiveness in critically ill patients. The method is very attractive due to the ease of access to the carotid artery, reproducibility, low cost, and since the FTC is a measurement of time (not velocity), the angle of insonation should be inconsequential, making the exam technically easier to perform compared to carotid artery VTI. This can be compared to a 10% increase in SVI following a PLR demonstrated by the Flotrac/Vigileo being considered the "gold standard". While the absolute values of cardiac output obtained with the Flotrac/Vigileo when compared with the PAC are debatable, the ability of the device to track changes in cardiac output/stroke volume in response to changes in preload and PLR have been shown to be accurate.16-19 A meta-analysis published by Cavallaro and colleagues showed that PLR induced changes in cardiac output were able to predict fluid responsiveness with a sensitivity and specificity of 89.4% and 91.4% with a pooled area under the ROC value of 0.95 regardless of ventilation mode, underlying cardiac rhythm, and technique of measurement. Thus, an increase in SVI \> 10% with PLR detected by a Flotrac/Vigileo monitor without the need for a fluid bolus, should be sufficient to determine whether PLR induced changes in carotid FTC are able to detect fluid responsiveness.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Carotid Artery Flow Time
Patients with radial aline and flotrac vigileo will have carotid dopper measured for carotid flow time and a passive leg raise
Carotid Doppler Measurement in response to passive leg raise
The investigators will measure Carotid Flow time in the semi-recumbent position, then lay the patient flat and do a passive leg raise. The investigators will then meausre Carotid Flow Time at 1 minute, 2 minutes, and 3 minutes. Patients who have 10 % increase in stroke volume on the Flotrac / Vigileo monitor will be considered fluid responders. The investigators will try to identify an optimum % increase of Carotid Flow Time that can predict fluid responsiveness.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Carotid Doppler Measurement in response to passive leg raise
The investigators will measure Carotid Flow time in the semi-recumbent position, then lay the patient flat and do a passive leg raise. The investigators will then meausre Carotid Flow Time at 1 minute, 2 minutes, and 3 minutes. Patients who have 10 % increase in stroke volume on the Flotrac / Vigileo monitor will be considered fluid responders. The investigators will try to identify an optimum % increase of Carotid Flow Time that can predict fluid responsiveness.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* admitted to ICU and already have an arterial line and Flotrac/Vigileo monitor in place ordered by primary team as part of their clinical standard practice.
Exclusion Criteria
* clinically suspected or known intraabdominal hypertension,
* lower extremity amputee,
* femoral arterial line,
* poor or unreliable arterial line waveform,
* history of carotid endarterectomy in the artery being measured,
* pregnancy
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Louisville
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Mohamed Saad
PI
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Louisville
Louisville, Kentucky, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
14.0272
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.