Radio Frequency Ablation for Atrial Flutter With Magnetic Resonance Guidance and Tracking
NCT ID: NCT02380937
Last Updated: 2018-02-06
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
NA
8 participants
INTERVENTIONAL
2015-01-31
2015-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter
NCT02699034
Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter II
NCT03078985
Catheter Ablation as the First Line Therapy for Typical Atrial Flutter
NCT00213408
Fluoroscopic, Contact Force and Local Impedance With Ultra-high Density Mapping Guided Radiofrequency Ablation Comparison for cavoTricuspid Isthmus dependenT Atrial fluttER: the FLUTTER Study
NCT04434599
Identification of Risk Factors for Atrial Fibrillation After Ablation of an Atrial Flutter by Radiofrequency of the Cavotricuspid Isthmus.
NCT03919097
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The study will be conducted at a single center, Herzzentrum Leipzig University Hospital, in Germany, and a maximum of 30 subjects meeting inclusion/exclusion criteria will participate in the study. This study requires the use of investigational products from two independent manufacturers: Imricor and Philips. Imricor has developed the ablation catheter with related accessories, introducers, and recording system. Philips has developed an image guidance and mapping system that is compatible with the Imricor products. The Vision Ablation Catheter will be used in conjunction with the following investigational products: Vision Ablation Catheter Cable Set (accessory sterile cable), Vision Hemostasis Introducer, Vision Dual-Deflect Sheath, Horizon recording system, and the interventional MRI Suite (iSuite) image guidance and mapping system. With the exception of iSuite, which is manufactured by Philips, Imricor will provide all investigational devices used in the study. Each procedure will utilize the following two single-use products: two Vision Ablation Catheters and an accessory Catheter Cable set. At the discretion of the investigator, Vision Hemostasis Introducers may be used for femoral access and a Vision Dual- Deflect Sheath and may be used in conjunction with the Vision Ablation Catheter Cable Set. Ablation for the treatment of arrhythmia is an inherently complex procedure. Use of the investigational products listed above under magnetic resonance guidance is a new approach to performing the interventional electrophysiology procedure. The study population will consist of adult patients requiring ablation for type I atrial flutter.
Study subjects will require a follow-up visit or telephone call at 7 days post procedure.
Accordingly, the expected total study duration is approximately six months with study start planned for October 2014.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ablation for typical atrial flutter
This group receives an MR-guide ablation for atrial flutter with the study device (catheter)
ablation for typical atrial flutter
ablation for typical atrial flutter
Vision Ablation Catheter
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
ablation for typical atrial flutter
ablation for typical atrial flutter
Vision Ablation Catheter
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age 18 or above
* Patients willing and able (mentally and physically capable per physician's discretion) to understand the investigational nature, potential risks and benefits of the study and able to provide written informed consent to participate in the study and agree to comply with follow-up visits and evaluation
* Patients able to receive anticoagulation therapy to achieve adequate anticoagulation
Exclusion Criteria
* A cardiac ablation or cardiac surgery within 90 days prior to enrollment
* Documented intracardiac thrombus, tumor, bleeding, clotting or other abnormality that precludes catheter introduction and placement
* Myocardial infarction within 60 days prior to enrollment
* Current unstable angina
* History of cerebrovascular event (within 180 days prior to enrollment)
* Patients with an ejection fraction less than or equal to 30% within 90 day prior to enrollment
* Permanent leads in or through the right atrium
* Clinically significant structural heart disease (including tricuspid valve regurgitation, tricuspid valve stenosis or other congenital heart disease) that would preclude catheter introduction and placement, as determined by the Investigator
* Uncompensated congestive heart failure (NYHA Class III or IV)
* Arrhythmia is secondary to electrolyte imbalance, thyroid disease, or other
* reversible or non-cardiovascular cause
* Known sensitivity to heparin or warfarin
* Active or systemic infection
* Any other significant uncontrolled or unstable medical condition (including but not limited to hypertension and diabetes)
* Women who are pregnant or plan to become pregnant within the course of their participation in the investigation or who are breastfeeding
* Life expectancy of less than 12 months
* Patients with prosthetic valves
* Contraindicated for transfemoral venous access
* Older than 75 years
* Current enrollment in any other clinical investigation
18 Years
75 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Heart Center Leipzig - University Hospital
OTHER
Philips Healthcare
INDUSTRY
Imricor Medical Systems
INDUSTRY
University of Leipzig
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Gerhard Hindricks, Professor
Role: PRINCIPAL_INVESTIGATOR
Heart Center Leipzig
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Heart Center Leipzig
Leipzig, , Germany
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Sommer P, Grothoff M, Eitel C, Gaspar T, Piorkowski C, Gutberlet M, Hindricks G. Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans. Europace. 2013 Jan;15(1):101-8. doi: 10.1093/europace/eus230. Epub 2012 Jul 31.
Eitel C, Hindricks G, Grothoff M, Gutberlet M, Sommer P. Catheter ablation guided by real-time MRI. Curr Cardiol Rep. 2014 Aug;16(8):511. doi: 10.1007/s11886-014-0511-6.
Piorkowski C, Grothoff M, Gaspar T, Eitel C, Sommer P, Huo Y, John S, Gutberlet M, Hindricks G. Cavotricuspid isthmus ablation guided by real-time magnetic resonance imaging. Circ Arrhythm Electrophysiol. 2013 Feb;6(1):e7-10. doi: 10.1161/CIRCEP.112.973719. No abstract available.
Hilbert S, Sommer P, Gutberlet M, Gaspar T, Foldyna B, Piorkowski C, Weiss S, Lloyd T, Schnackenburg B, Krueger S, Fleiter C, Paetsch I, Jahnke C, Hindricks G, Grothoff M. Real-time magnetic resonance-guided ablation of typical right atrial flutter using a combination of active catheter tracking and passive catheter visualization in man: initial results from a consecutive patient series. Europace. 2016 Apr;18(4):572-7. doi: 10.1093/europace/euv249. Epub 2015 Aug 27.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
104/14-ff
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.