Laparoscopic Lightweight Mesh Repair of Large Hiatal Hernias
NCT ID: NCT01408108
Last Updated: 2015-10-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE3
100 participants
INTERVENTIONAL
2013-01-31
2016-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
NCT01780285
A Prospective Randomised Multi - Center Trial on the Repair of Large Hiatal Hernias: Absorbable Mesh vs. Pledgeted Sutures vs. Sutures Only
NCT04591860
Study of a New Laparoscopic Technique for Parastomal Hernia Repair With Mesh
NCT00138957
Light vs Heavy Weighted Mesh Repair in Primary Abdominal Hernia in Terms of Surgical Site Infection
NCT06644612
Nationwide Long-term Outcome Surveillance of Physiomesh® vs. Other Meshes in Laparoscopic Incisional Hernia Repair
NCT03846661
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
There is insufficient grade 1 evidence for choice of optimal method of repair of large hiatal hernias. Only 3 prospective randomized trials comparing prosthetic and primary hiatal repair were published by Frantzides et al (2002), Granderath et al (2005), and Oelschlager et al (2006). However, these trials could not recommend effective, safe, and relatively inexpensive method of repair. Although Frantzides et al (2002) showed statistically significant decrease of recurrence rate in composite (ePTFE) mesh arm, the study included only patients with diameter of defect 8 cm and greater, thus it is still unknown whether mesh should be used for hernias with smaller diameter of hernia defect, for example, between 5 and 8 cm. Most specialists use mesh when the diameter of the defect is just greater than 5 cm, based on their own experience and widespread literature data, including studies of Champion et al (1998, 2003). In addition, hiatal surface area (HSA), first described by Granderath et al (2007), is more sensitive measure than diameter of hiatal hernia defect, and further trials should focus on it. Finally, ePTFE prosthesis is rather expensive.
The trial of Granderath et al (2005) also was not primarily focused of relation between diameter of hernia defect and rate of recurrences. In this study, recurrence rate was also smaller in the polypropylene arm, but the rate of dysphagia was lager in the same arm. Although later these authors reported that differences between arms in rates of dysphagia and motility disorders vanished in 1 year, most of authors still consider polypropylene mesh potentially unsafe (Frantzides et al, 2010).
To remove the risk of mesh-related oesophageal complications, biological prostheses were introduced for hiatal repair, but the study of Oelschlager et al (2006) demonstrated insignificant difference in recurrence rates in prosthesis arm compared to primary repair arm, although no cases of mesh-related complications were observed in prosthesis arm. Data from the literature and international congresses suggest that biological devices cannot be widely used in the setting of large hiatal hernias due to high rate of recurrences and their high price. Data from another recent numerous publications including reviews made the same conclusions that large and giant hiatal hernias require mesh repair but search for the optimal prosthesis and fashion of its fixation is ongoing.
Hiatal repair by partially absorbable lightweight meshes is promising technique and may become an optimal because it can minimize both recurrences and oesophageal complications. Hazebroek et al (2008) reported good functional, endoscopic, and radiological outcomes in terms of esophageal complications after on-lay placement of titanium-coated lightweight polypropylene mesh (non-randomized prospective study). Our own experience of 400 repairs using lightweight mesh (Ultrapro, Ethicon) and original sub-lay technique of its fixation precluding contact of the mesh with the oesophagus, showed low recurrence rate (4,9%) and a few cases of long-term dysphagia (2,1%). Therefore, the hypothesis of our double-blind prospective randomized trial is: original technique of lightweight mesh (Ultrapro, Ethicon) repair is highly effective for prevention of recurrences compared to primary repair and safe in terms of mesh-related dysphagia and oesophageal strictures.
The study will enroll at least 100 patients with large (i.e. with hiatal surface area (HSA) ranging from 10 to 20 sq.cm, which corresponds to diameter of defect from 5 to 8 cm) types I, II, and III hiatal hernias. The chosen size of the defect is the most questionable in terms of the need for applying a mesh: when HSA is 20 sq.cm or greater the necessity of mesh repair is obvious, when it is less than 10 sq.cm usage of mesh is unreasonable. The basic eligibility criteria will be: absence of oesophageal motility disorders, absence of oesophageal shortening requiring Collis procedure, absence of peptic strictures and other factors that may independently influence the rate of recurrence and dysphagia/oesophageal strictures. Thus, the only difference between arms will be method of hiatal closure. To exclude fundoplication-related bias, standard floppy-Nissen procedure will be performed in every patient.
Every patient will be operated by single surgical team with an experience of more than 1500 laparoscopic anti-reflux procedures since 1998. The necessary ethic regulations will be saved including informed consent with the statement that patient is unaware of the method of repair (double-masked). Every patient is going to be evaluated preoperatively, 6 months, and 24 months postoperatively using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, and 24-hour pH testing. For issue of efficacy of prosthetic repair, recurrence rate of hernia and GERD, which are the primary outcome measure, will be studied. For issue of safety of prosthetic repair, rates of short- and long-term dysphagia/oesophageal strictures/mesh erosions, which are main secondary outcome measure, will be evaluated.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Lightweight mesh repair
Laparoscopic hiatal repair with sub-lay partially absorbable lightweight mesh
Laparoscopic hiatal repair with sub-lay partially absorbable lightweight mesh
A fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro™ (Ethicon, Inc.) will be sutured to both crura with 3 to 5 interrupted non-absorbable (Ethibond™ 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique).
Primary crural repair
Laparoscopic primary posterior crural repair
Laparoscopic primary posterior crural repair
Posterior cruroraphy will be performed with 3 to 4 interrupted non-absorbable (Ethibond™ 3-0 by Ethicon, Inc.) sutures.
In the both arms laparoscopic procedure will be done in a standard fashion: reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening including crura posteriorly to esophagus, repair if hiatal hernia defect (30 Fr esophageal bougie is used), a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure) (30 Fr esophageal bougie is used).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Laparoscopic hiatal repair with sub-lay partially absorbable lightweight mesh
A fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro™ (Ethicon, Inc.) will be sutured to both crura with 3 to 5 interrupted non-absorbable (Ethibond™ 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique).
Laparoscopic primary posterior crural repair
Posterior cruroraphy will be performed with 3 to 4 interrupted non-absorbable (Ethibond™ 3-0 by Ethicon, Inc.) sutures.
In the both arms laparoscopic procedure will be done in a standard fashion: reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening including crura posteriorly to esophagus, repair if hiatal hernia defect (30 Fr esophageal bougie is used), a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure) (30 Fr esophageal bougie is used).
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Able to undergo elective laparoscopic hiatal hernia repair
* Able to 24 months follow-up with office examinations
* Hiatal surface area (HSA) measuring 10 to 20 sq.cm (by granderath et al, 2007) which correspond to the diameter of hernia defect measuring 5 to 8 cm (the distinct size is determined intraoperatively, those with smaller or larger diameter will be excluded from the study)
Exclusion Criteria
* Cases of conversion to open surgery
* Age \< 20 years and \> 80 years
* BMI \< 16 and \> 39 kg/m2
* Pregnancy or plans for pregnancy within next 2 years (in females)
* Uncorrectable coagulopathy and immunosuppression
* Oesophageal motility disorders
* Oesophageal peptic strictures
* Oesophageal diverticula, other types (i.e. non-reflux) of chronic esophagitis, connective tissue disorders (e.g. scleroderma)
* Oesophageal shortening (determined intraoperatively as inability to achieve intra-abdominal length of oesophagus at least 3 cm in spite of intramediastinal oesophageal mobilization)
* Barrett's oesophagus
* History of oesophageal/gastric/duodenal surgery including vagotomy
* Relapsing course of ulcer disease/hyperacid gastritis including complicated by delayed gastric/duodenal emptying
20 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Odessa National Medical University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Dr. Andriy V. Malynovskyy
Assistant of department of surgery # 1
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Volodymyr V. Grubnik, Prof., MD
Role: PRINCIPAL_INVESTIGATOR
Department of surgery # 1 of Odessa national medical university
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of surgery # 1 of Odessa national medical university, Odessa regional hospital
Odesa, , Ukraine
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP. A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg. 2002 Jun;137(6):649-52. doi: 10.1001/archsurg.137.6.649.
Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R. Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg. 2005 Jan;140(1):40-8. doi: 10.1001/archsurg.140.1.40.
Oelschlager BK, Pellegrini CA, Hunter JG, Brunt ML, Soper NJ, Sheppard BC, Polissar NL, Neradilek MB, Mitsumori LM, Rohrmann CA, Swanstrom LL. Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg. 2011 Oct;213(4):461-8. doi: 10.1016/j.jamcollsurg.2011.05.017. Epub 2011 Jun 29.
Champion JK, McKernan JB. Hiatal size and risk of recurrence after laparoscopic fundoplication [abstract]. Surg Endosc. 1998; 12:565-570.
Champion JK, Rock D. Laparoscopic mesh cruroplasty for large paraesophageal hernias. Surg Endosc. 2003 Apr;17(4):551-3. doi: 10.1007/s00464-002-8817-7. Epub 2003 Feb 17.
Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A. Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc. 2010 May;24(5):1017-24. doi: 10.1007/s00464-009-0718-6. Epub 2009 Dec 8.
Hazebroek EJ, Ng A, Yong DH, Berry H, Leibman S, Smith GS. Evaluation of lightweight titanium-coated polypropylene mesh (TiMesh) for laparoscopic repair of large hiatal hernias. Surg Endosc. 2008 Nov;22(11):2428-32. doi: 10.1007/s00464-008-0070-2. Epub 2008 Jul 15.
Granderath FA, Schweiger UM, Pointner R. Laparoscopic antireflux surgery: tailoring the hiatal closure to the size of hiatal surface area. Surg Endosc. 2007 Apr;21(4):542-8. doi: 10.1007/s00464-006-9041-7. Epub 2006 Nov 14.
Grubnik VV, Malynovskyy AV. Laparoscopic repair of hiatal hernias: new classification supported by long-term results. Surg Endosc. 2013 Nov;27(11):4337-46. doi: 10.1007/s00464-013-3069-2. Epub 2013 Jul 23.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ONMU-1
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.