Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
NCT ID: NCT01780285
Last Updated: 2016-06-30
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
PHASE3
50 participants
INTERVENTIONAL
2013-06-30
2017-02-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Laparoscopic Lightweight Mesh Repair of Large Hiatal Hernias
NCT01408108
A Prospective Randomised Multi - Center Trial on the Repair of Large Hiatal Hernias: Absorbable Mesh vs. Pledgeted Sutures vs. Sutures Only
NCT04591860
Prospective Trial Comparing Two Different Polypropylene Meshes for Inguinal Hernias
NCT01825187
The Influence of Closing the Gap on Postoperative Seroma and Recurrences in Laparoscopic Ventral Hernia Repair
NCT01719718
Trial Concerning the Frequency of Parastomal Hernia With or Without a Mesh
NCT00917995
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
As the most concerning problem or repair of giant hiatal hernias is anatomical recurrence, a conception of prosthetic repair was applied for hiatal closure using different types of meshes. This dramatically decreased recurrence rate as demonstrated by several recent studies. Namely, Frantzides et al (2002) prospectively compared primary repair with on-lay PTFE repair and obtained statistically significant decrease of recurrence rate in favor of mesh arm: 0% versus 22%. Then, Granderath et al (2004) compared primary suturing and on-lay polypropylene mesh repair in prospective randomized trial; the rate of recurrence was significantly lower in the mesh arm: 8% versus 26%. Unfortunately, these studies were not primarily addressed to relation between hernia size and results. Most specialists use mesh when the diameter of the defect is just greater than 5 cm, based on own experience and widespread literature data, including studies of Champion et al (1998, 2003). Hiatal surface area (HSA), first described by Granderath et al (2007), is more sensitive measure than diameter of hiatal hernia defect, and further trials should focus on it.
However, SAGES trial reported by Frantzides et al. (2010) showed that polypropylene or PTFE meshes are characterized by the highest incidence of oesophageal complications although they demonstrated relatively lower recurrence rates compared to other meshes. According to most of the literature, mesh-related dysphagia rate is 10-15 % in the long-term follow-up \[Granderath et al, 2005, Targarona et al, 2004\]. Interestingly, that composite, i.e. partially absorbable meshes, occupied middle position in terms of recurrence and complications rates in this study \[Frantzides et al, 2010\]. Own experience of the interventors of more than 400 laparoscopic hiatal repairs using lightweight partially absorbable mesh (Ultrapro, Ethicon) showed minimal rate of recurrence (4,9 %) and dysphagia (2,1 %) for large (HSA 10-20 sq.cm) hernias \[Grubnik et al, 2011\]. The interventors applied this safe technique for giant (HSA \> 20 sq.cm) hiatal hernias, but recurrence rate was 20 % \[Grubnik et al, 2011\]. This result corresponds to the literature, but may be improved. The interventors believe, it is possible to minimize recurrence rate of giant hiatal hernias, but it could be achieved by introduction of fundamentally new types of prostheses and methods of its fixation.
To remove the risk of mesh-related oesophageal complications of polypropylene or PTFE meshes, biological prostheses were introduced for hiatal repair. However, prospective randomized study by Oelschlager et al (2010) demonstrated insignificant difference in recurrence rates in prosthesis arm compared to primary repair arm (more than 50 %), although no cases of mesh-related complications were observed in prosthesis arm. Similar data regarding biological prostheses were retrieved in the study of Frantzides et al (2010). Data from the literature and international congresses suggest that current biological prostheses cannot be widely used in the setting of giant hiatal hernias due to high rate of recurrences and their high price. Thus, based on current literature data, there is insufficient grade 1 evidence for choice of optimal method of repair of giant hiatal hernias, and the search for the optimal prosthesis is still ongoing.
Therefore, a fundamentally new prosthesis for laparoscopic repair of giant hiatal defects was created. The prototype prosthesis "Rebound HRD-Hiatus hernia" was created by the interventors in collaboration with U.S. company, Minnesota Medical Development, Inc. This device is made from high quality lightweight PTFE mesh attached to a heart-shaped nitinol frame with a notch for oesophagus. Prosthesis may be easily inserted through the trocar using a special tube, and expanded to its initial form inside the abdomen. The principle and purpose of using of the device and method of its fixation was patented in Ukraine (patents No. 66397, 66399). The interventors applied new prosthesis in 29 patients, operated from 2010. All procedures were successfully completed. Two main principles are used in a new prosthesis. First, mesh is made of lightweight PTFE minimizing possibility of adhesions and related complications. As a result, there were no esophageal complications in the cohort. Second, peripheral nitinol frame of the prosthesis provides real tension-free repair without risk of prolapse between free, i.e. anterior, margin of the mesh and oesophagus, which other meshes do if fixed to the borders of the hiatus. As a result, there were no recurrences within mean surveillance of 15 months in this series. Naturally, final conclusions regarding superior efficacy and safety of the new device could be established by prospective randomized study.
Therefore, the hypothesis of this double-blind prospective randomized trial is: new method of nitinol-framed lightweight PTFE mesh (Rebound HRD-Hiatus hernia, Minnesota Medical Development, Inc) repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh (Ultrapro, Ethicon, Inc) repair, and is characterized by at least similar safety in terms of oesophageal complications.
The study will enroll at least 50 patients with giant (HSA \> 20 sq.cm) types II and III hiatal hernias. The basic eligibility criteria will be: absence of oesophageal motility disorders, absence of oesophageal shortening requiring Collis procedure, absence of Barrett's oesophagus, peptic strictures and other factors that may independently influence the rate of recurrence and dysphagia/oesophageal strictures. Thus, the only difference between arms will be method of hiatal closure. To exclude fundoplication-related bias, standard floppy-Nissen procedure will be performed in every patient.
Every patient will be operated by single surgical team with an experience of more than 1500 laparoscopic anti-reflux procedures since 1998. The necessary ethic regulations will be saved including informed consent with the statement that patient is unaware of the method of repair (double-masked). Every patient will be evaluated preoperatively, 6 months, and 24 months postoperatively using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations. For issue of efficacy of prosthetic repair, recurrence rate of hernia and GERD, which are the primary outcome measure, will be studied. For issue of safety of prosthetic repair, rates of long-term dysphagia/oesophageal strictures/mesh erosions, which are main secondary outcome measure, will be evaluated.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Nitinol-framed PTFE mesh hiatal repair
Nitinol-framed lightweight PTFE mesh for hiatal repair
Nitinol-framed lightweight PTFE mesh for hiatal repair
The heart-shaped nitinol-framed lightweight PTFE prosthesis "Rebound HRD-Hiatus hernia" (Minnesota Medical Development, Inc.) of small (4,0 x 4,5 cm) to large size (5,5 х 6,0 cm) is sutured to the crura posteriorly to oesophagus with 3 or 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures, thus performing complete tension-free hiatal repair.
Lightweight mesh hiatal repair
Partially absorbable lightweight mesh for hiatal repair
Partially absorbable lightweight mesh for hiatal repair
A fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro (Ethicon, Inc.) will be sutured to both crura posteriorly to oesophagus with 3 to 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique).
In both arms procedure will be done in a standard fashion: placement of 30 Fr esophageal bougie, reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening, repair of hiatal hernia defect, a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure).
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Nitinol-framed lightweight PTFE mesh for hiatal repair
The heart-shaped nitinol-framed lightweight PTFE prosthesis "Rebound HRD-Hiatus hernia" (Minnesota Medical Development, Inc.) of small (4,0 x 4,5 cm) to large size (5,5 х 6,0 cm) is sutured to the crura posteriorly to oesophagus with 3 or 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures, thus performing complete tension-free hiatal repair.
Partially absorbable lightweight mesh for hiatal repair
A fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro (Ethicon, Inc.) will be sutured to both crura posteriorly to oesophagus with 3 to 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique).
In both arms procedure will be done in a standard fashion: placement of 30 Fr esophageal bougie, reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening, repair of hiatal hernia defect, a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure).
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Able to undergo elective laparoscopic hiatal hernia repair,
* Able to 24 months follow-up with office examinations,
* Hiatal surface area (HSA) exceeding 20 sq.cm (by Granderath et al, 2007) which correspond to the diameter of hernia defect exceeding 8 cm (the distinct size is determined intraoperatively, those with smaller diameter will be excluded from the study),
* Nissen fundoplication (intraoperative criterion)
Exclusion Criteria
* Cases of conversion to open surgery
* Age \< 20 years and \> 80 years
* BMI \< 16 and \> 39 kg/sq.m
* Pregnancy or plans for pregnancy within next 2 years (in females)
* Uncorrectable coagulopathy and immunosuppression
* Oesophageal motility disorders
* Oesophageal peptic strictures
* Oesophageal diverticula, other types (i.e. non-reflux) of chronic esophagitis, connective tissue disorders (e.g. scleroderma)
* Oesophageal shortening (determined intraoperatively as inability to achieve intra-abdominal length of oesophagus at least 3 cm in spite of intramediastinal oesophageal mobilization)
* Barrett's oesophagus
* History of oesophageal/gastric/duodenal surgery including vagotomy
* Relapsing course of ulcer disease/hyperacid gastritis including complicated by delayed gastric/duodenal emptying
20 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Odessa National Medical University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Dr. Andriy V. Malynovskyy
Assistant of department of surgery No. 1
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Volodymyr V. Grubnik, Prof., MD
Role: PRINCIPAL_INVESTIGATOR
Department of surgery No. 1 of Odessa national medical university
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of surgery No. 1 of Odessa national medical university, Odessa regional hospital
Odesa, Ukaraine, Ukraine
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Draaisma WA, Gooszen HG, Tournoij E, Broeders IA. Controversies in paraesophageal hernia repair: a review of literature. Surg Endosc. 2005 Oct;19(10):1300-8. doi: 10.1007/s00464-004-2275-3. Epub 2005 Aug 4.
Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP. A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg. 2002 Jun;137(6):649-52. doi: 10.1001/archsurg.137.6.649.
Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R. Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg. 2005 Jan;140(1):40-8. doi: 10.1001/archsurg.140.1.40.
Grubnik VV, Malinovskii AV. [Analysis of long-term results of laparoscopic repair of hiatal hernias and Nissen fundoplication]. Klin Khir. 2012 Oct;(10):34-6. No abstract available. Russian.
Oelschlager BK, Pellegrini CA, Hunter JG, Brunt ML, Soper NJ, Sheppard BC, Polissar NL, Neradilek MB, Mitsumori LM, Rohrmann CA, Swanstrom LL. Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg. 2011 Oct;213(4):461-8. doi: 10.1016/j.jamcollsurg.2011.05.017. Epub 2011 Jun 29.
Champion JK, McKernan JB. Hiatal size and risk of recurrence after laparoscopic fundoplication [abstract]. Surg Endosc. 1998; 12:565-570.
Champion JK, Rock D. Laparoscopic mesh cruroplasty for large paraesophageal hernias. Surg Endosc. 2003 Apr;17(4):551-3. doi: 10.1007/s00464-002-8817-7. Epub 2003 Feb 17.
Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A. Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc. 2010 May;24(5):1017-24. doi: 10.1007/s00464-009-0718-6. Epub 2009 Dec 8.
Granderath FA, Schweiger UM, Pointner R. Laparoscopic antireflux surgery: tailoring the hiatal closure to the size of hiatal surface area. Surg Endosc. 2007 Apr;21(4):542-8. doi: 10.1007/s00464-006-9041-7. Epub 2006 Nov 14.
Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ. Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc. 2006 Mar;20(3):362-6. doi: 10.1007/s00464-005-0357-5. Epub 2006 Jan 25.
Nguyen NT, Christie C, Masoomi H, Matin T, Laugenour K, Hohmann S. Utilization and outcomes of laparoscopic versus open paraesophageal hernia repair. Am Surg. 2011 Oct;77(10):1353-7.
Rathore MA, Andrabi SI, Bhatti MI, Najfi SM, McMurray A. Metaanalysis of recurrence after laparoscopic repair of paraesophageal hernia. JSLS. 2007 Oct-Dec;11(4):456-60.
Targarona EM, Bendahan G, Balague C, Garriga J, Trias M. Mesh in the hiatus: a controversial issue. Arch Surg. 2004 Dec;139(12):1286-96; discussion 1296. doi: 10.1001/archsurg.139.12.1286.
Grubnik VV, Malynovskyy AV. Laparoscopic repair of hiatal hernias: new classification supported by long-term results. Surg Endosc. 2013 Nov;27(11):4337-46. doi: 10.1007/s00464-013-3069-2. Epub 2013 Jul 23.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
ONMU-2
Identifier Type: -
Identifier Source: org_study_id