Comparison of the Ultrasonic Cardiac Output Monitor and Echocardiography for Hemodynamic Assessment in Pediatric Anesthesia

NCT ID: NCT07342842

Last Updated: 2026-01-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

57 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-03-01

Study Completion Date

2022-03-15

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This prospective observational pilot study evaluates agreement between Ultrasound Cardiac Output Monitor (USCOM) measurements and transthoracic echocardiography-derived hemodynamic parameters in pediatric patients under standardized general anesthesia prior to surgical incision. Under stable hemodynamic and ventilatory conditions, suprasternal Doppler-derived velocity time integral (VTI), stroke volume (SV), cardiac output (CO), stroke volume variation (SVV), and aortic valve area (AVA) are obtained sequentially with USCOM and echocardiography within a short time window without changes in ventilation, anesthetic depth, positioning, fluid therapy, or vasoactive support. Agreement is assessed using correlation and Bland-Altman analyses.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This prospective observational pilot study is designed to evaluate the agreement between Ultrasound Cardiac Output Monitor (USCOM) measurements and transthoracic echocardiography-derived hemodynamic parameters in pediatric patients undergoing elective surgery under standardized general anesthesia.

After anesthesia induction and airway management, patients are allowed to reach stable hemodynamic and ventilatory conditions. Heart rate, noninvasive blood pressure, peripheral oxygen saturation, tidal volume, respiratory rate, and positive end-expiratory pressure are documented to confirm comparable physiological conditions during all measurements.

All measurements are performed before surgical incision and under unchanged ventilator settings, anesthetic depth, and patient positioning. No fluid administration, vasoactive medication, or ventilatory adjustments are made between techniques.

USCOM measurements are obtained first using a suprasternal approach to acquire spectral Doppler signals. Device-derived parameters, including velocity time integral (VTI), stroke volume (SV), cardiac output (CO), stroke volume variation (SVV), systemic vascular resistance (SVR), and device-calculated aortic valve area (AVA), are recorded consecutively during spontaneous or controlled mechanical ventilation without apnea. Only Doppler signals with clearly defined spectral envelopes are accepted. Measurements with artifacts or poor signal quality are repeated until optimal tracings are achieved.

Immediately afterward, transthoracic echocardiography is performed using a pediatric probe. Suprasternal Doppler recordings are aligned as parallel as possible to blood flow in the ascending aorta, and angle correction is applied when required. VTI is measured from the largest and most clearly defined spectral Doppler envelope. The aortic annulus diameter is obtained from the parasternal long-axis view during midsystole, and aortic valve area is calculated. Stroke volume is derived as aortic valve area × VTI, and cardiac output is calculated as stroke volume × heart rate. Inspiratory and expiratory VTI values are recorded to determine respiratory variation and calculate SVV.

USCOM and echocardiography measurements are performed sequentially within a 1-2-minute time window to minimize the impact of temporal hemodynamic variability. Each parameter is measured three consecutive times, and the average value is used for statistical analysis.

All examinations are conducted by a single experienced operator who completed supervised echocardiography training and independently performed at least 30 validated measurements before study initiation to minimize interobserver variability.

The primary objective is to assess agreement between USCOM and echocardiography for stroke volume and cardiac output measurements. Secondary objectives include correlation of suprasternal VTI values, agreement in SVV measurements, comparison of USCOM-calculated versus echocardiography-derived aortic valve area, and Bland-Altman analysis of all paired hemodynamic parameters.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

USCOM Echocardiography Echocardiography Guided Fluid Management

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

USCOM

Ultrasound cardiac output monitoring is performed using a suprasternal approach to obtain spectral Doppler signals from the ascending aorta. After anesthesia induction and stabilization, the probe is positioned at the suprasternal notch to acquire optimal Doppler waveforms. Velocity time integral (VTI), stroke volume (SV), cardiac output (CO), stroke volume variation (SVV), systemic vascular resistance (SVR), and device-calculated aortic valve area (AVA) are recorded using the manufacturer's algorithm. Only high-quality Doppler envelopes are accepted, and measurements are repeated if artifacts or poor signal quality are present. All parameters are obtained consecutively under unchanged ventilatory and hemodynamic conditions.

Intervention Type OTHER

Echocardiography

Transthoracic echocardiography is performed immediately after USCOM measurements under unchanged anesthetic depth, ventilator settings, and patient positioning. Using a pediatric probe, suprasternal Doppler recordings are obtained from the ascending aorta, with the Doppler cursor aligned as parallel as possible to blood flow; angle correction is applied when necessary. Velocity time integral (VTI) is measured from the largest and most clearly defined spectral Doppler envelope. The aortic annulus diameter is obtained from the parasternal long-axis view during midsystole, and aortic valve area is calculated. Stroke volume is derived as aortic valve area × VTI, and cardiac output is calculated as stroke volume × heart rate. Inspiratory and expiratory VTI values are recorded to determine respiratory variation and calculate stroke volume variation. Each parameter is measured three times and averaged for analysis.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Pediatric patients aged 6 months to 15 years
* ASA physical status I-II
* Scheduled for elective surgery requiring general anesthesia
* Written informed consent obtained from parent(s) or legal guardian(s)

Exclusion Criteria

* Intracardiac or extracardiac shunts
* Aortic valve disease
* Anatomical limitation preventing suprasternal Doppler assessment
* Required Doppler angle correction \>20° during echocardiography evaluation
* Emergency surgery
* Inability to obtain informed consent
Minimum Eligible Age

6 Months

Maximum Eligible Age

15 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Sehit Prof. Dr. Ilhan Varank Sancaktepe Training and Research Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Volkan Kuzlu

principal investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Marmara University Faculty of medicine

Istanbul, , Turkey (Türkiye)

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Turkey (Türkiye)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

USCOM-Echo

Identifier Type: -

Identifier Source: org_study_id

More Related Trials