Validation of the Use of Terahertz Scanning System on Corneal Scars and Corneal Edema
NCT ID: NCT06983652
Last Updated: 2025-05-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
150 participants
OBSERVATIONAL
2024-07-01
2026-08-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optical Coherence Tomography Guided Transepithelial Phototherapeutic Keratectomy
NCT01243931
Effectiveness and Safety of the TENEO 317 Model 2 Excimer Laser to Treat Myopia With or Without Astigmatism by Transepithelial Photorefractive Keratectomy
NCT06618547
Measuring Corneal Cells With Specular Microscopy
NCT01792154
Feasibility and Tolerability Study of Smart Contact Lens With Healthy Subjects and Patients With Stargardt's Disease
NCT06989658
Laser Acupuncture for Dry Eye Disease Due to Visual Display Terminal Use
NCT06688630
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Terahertz (THz) waves are electromagnetic radiation, and have emerged as a novel, non-invasive and non-contact imaging modality in the biomedical field, with a fast-scanning speed (30ms per scan) to meet medical diagnostic needs. With its fast scanning, it provides a more accurate result for the estimation of corneal thickness. Its high sensitivity hydration absorption and characterization peaks of collagen will provide a useful tool to obtain information that are related to the corneal layers. Water has a high dielectric constant and is highly absorptive to THz spectrum. This allows THz wave to be highly sensitive to water content in tissue. Furthermore, THz scan has been applied to a variety of hydration-related diseases or conditions. With THz scan, early detection of disease and diagnosis can be carried out. Some examples would be the prediction of skin flap failure, diagnosis for the presence of caries lesion at its initial stage, identification of skin cancer in skin biopsy samples and to access the physiological dynamics of tear film in dry eye syndrome. Previous studies have demonstrated that THz scanning system could be used as an early diagnostic tool, to identify the cancerous area based on the lack of clear cellular order in the skin. It was able to detect disease conditions in deeper layers, allowing it to be an effective early diagnostic tool for basal cell carcinoma. Moreover, it had been confirmed that THz scanning system had the sensitivity to identify the difference in colon tissue composition. The findings showed that the properties of ex vivo tissue, had an increase in both absorption coefficient and refractive indices in disease tissue when compared to healthy tissue. A recent study showed that with THz scanning system, clinicians will be able to obtain different images, such as 3D imaging methods to provide multiple views of internal structures. Furthermore, with the THz scan, the process of water loss in an in vitro porcine corneal tissue could be determined using a THz reflection imaging system. It was found that THz wave was approximately linear to the water content concentration, and that the slope decreased monotonously with an increase in frequency. Thus THz imaging is suggested to be used for the clinical diagnosis of corneal edema or scars, dry eye diseases and corneal hydration in refractive surgery.
The investigators would like to conduct the clinical trial to validate the use of THz scanning system in human corneal edema and corneal scars.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
CROSS_SECTIONAL
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Corneal edema cohort
Patients with corneal endothelial dysfunction (Fuchs' endothelial dystrophy or other causes of bullous keratopathy) at any disease stage, with manifestation of corneal edema.
THz scanning using THz Imaging system.
The THz scanning system is non-invasive and non-contact. It is a prototype developed by Institute of Materials Research and Engineering (IMRE), A\*STAR, Singapore and is performed for the purpose of research. THz scanning will provide safety data in human and the measurement of cornea hydration status. Each THz scan will take approximately 1 second. Real-time data will be generated when participants are positioned in front of the device.
Corneal scar cohort
Patients with corneal scars from any cause, with the absence of corneal edema.
THz scanning using THz Imaging system.
The THz scanning system is non-invasive and non-contact. It is a prototype developed by Institute of Materials Research and Engineering (IMRE), A\*STAR, Singapore and is performed for the purpose of research. THz scanning will provide safety data in human and the measurement of cornea hydration status. Each THz scan will take approximately 1 second. Real-time data will be generated when participants are positioned in front of the device.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
THz scanning using THz Imaging system.
The THz scanning system is non-invasive and non-contact. It is a prototype developed by Institute of Materials Research and Engineering (IMRE), A\*STAR, Singapore and is performed for the purpose of research. THz scanning will provide safety data in human and the measurement of cornea hydration status. Each THz scan will take approximately 1 second. Real-time data will be generated when participants are positioned in front of the device.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Regardless of gender (Male/Female).
* Regardless of race (Chinese/Malay/Indian/Eurasian/Others).
* Willingness and ability to follow all instructions and comply with study schedule for study visit.
* Patients with corneal endothelial dysfunction (Fuchs' endothelial dystrophy or other causes of bullous keratopathy) at any disease stage OR Patients with corneal scars from any cause, with the absence of corneal edema.
* Ability to hold face sufficiently stable to undergo necessary scans.
Exclusion Criteria
* Unable to give consent
* Physically immobile/poor instructional compliance
* PI determined
* Pregnant/ breast feeding women
21 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Singapore Eye Research Institute
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Singapore National Eye Centre
Singapore, , Singapore
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2024-3286
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.