Autoguide Positioning Device for Multiple Stereotactic Biopsies
NCT ID: NCT06306118
Last Updated: 2025-04-03
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
25 participants
OBSERVATIONAL
2024-04-15
2025-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The aim of these biopsies in advance to the actual tumor resection will be to receive tumor tissue samples not altered in such a way that it is no longer adequate for further treatment. If not adequate, a so-called "undergrading" could occur, which means that the biological structure of the tumor is misjudged and further therapy does not achieve the desired effect in the patient.
On the one hand, certain tumor regions can drift due to a "brain shift" which leads to inaccurate tissue removal, and on the other hand samples are not altered by pressure or bleeding.
To carry out these biopsies, a robot positioning device (AutoGuide®) will be used that has already been approved and tested for this type of intervention. The use of the AutoGuide® is intended to ensure that the tumor sample is taken with the greatest possible precision.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Prognostic IntraOperative Biomarkers ideNtification in Tumor rElatEd suRgery
NCT06617208
Prospective Surgical Study on the Pattern of Electrical Activity in High Grade Glioma as a Predictor of Progression
NCT05565118
Supramarginal Resection in Glioblastoma Guided by Artificial Intelligence
NCT05735171
Biopsy Versus Resection in Elderly Glioblastoma Patients. A Prospective Cohort Study.
NCT05641220
Multicenter Safety Trial Assessing an Innovative Tumor Molecular and Cellular Print Medical Device in Glioma
NCT02077543
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Therefore, navigation-guidance was implemented and established over the last two decades. Using preoperatively compiled anatomical patient data from radiological images (Computerized Tomography \[CT\] or Magnetic Resonance Imaging \[MRI\] scans) a trajectory from entry to target point can be defined and matched intraoperatively on the patient's head.
In case of stereotactic needle biopsies, inaccuracy is associated with the acquisition of non-diagnostic samples in up to 24% of stereotactic biopsy series or non-representative tumor samples in up to 64% of biopsies. Therefore, serial biopsies could be performed to overcome this drawback - associated with an increased risk of intracranial hemorrhages, which have been reported in 0.3 - 59.8% of the cases and contribute considerably to the reported morbidity of 0-16.1% of this procedure.
The Autoguide® system is a modular guidance system for surgical invasive tools which provides a precise, submillimetric trajectory alignment according to the predefined navigation data.
After the development of this miniaturized robotic guidance system for neurosurgery was successfully finalized, AutoGuide®, a robot for clinical application in neurosurgery, is now commercially available from the Medtronic company.
Precision medicine requires highly accurate tissue sampling from radiologic targets. Thereby, multiple targets on molecular imaging (e.g., MR-spectroscopy, PET) are of interest in many cases. On the basis of the pathologist's diagnosis of these tissue samples, the oncologist can provide patient-specific targeted therapy - a current standard practice in modern cancer treatment.
The aim of this study is to perform a clinical series of multiple stereotactic needle biopsies with the AutoGuide® system previous of brain tumor resection to achieve a more accurate diagnosis of a possible hotspot within the tumor.
Prior to oncologic treatment, neurosurgical resection for maximum reduction of tumor cell load is still the basis of brain tumor treatment. During surgery, tissue sampling is performed manually by removing tumor tissue from hotspots as shown on the navigation system screen. This method of tissue harvesting, however, is prone to considerable inaccuracy due to the brain shift that occurs as soon as the craniotomy has been performed. High precision targeting is therefore required for highly accurate tissue sampling from radiologic targets to ensure correct postoperative therapy allocation.
A robotic system such as AutoGuide® has the potential to provide highly accurate tissue samples from hotspots of interest prior to craniotomy. This allows to send a highly relevant tumor sample to pathology for frozen section right at the very beginning of surgery for decisions about further resection.
The major advantage in AutoGuide® performed surgeries lies in its rapid re-alignment if multiple areas have to be targeted. Such "pre-resection biopsies" could be routinely performed before brain tumor surgery with only minimal additional time expenditure and a more accurate diagnosis of a hotspot area of the tumor.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Multiple stereotactic Tumor Biopsies during a Brain Tumor Resection
For pre-resection biopsy cases (3 target per patient), the targets will be selected from metabolite hotspots on MR-spectroscopy imaging and/or amino acid tracer uptake hotspots on PET imaging. Depending on the tumor location and surgical procedure, all biopsies will be performed via one single or multiple entry points.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Diagnosis of a cerebral lesion with the indication for surgical resection
* Written informed consent to participate in the present study
* MRI and CT scanner compatibility
Exclusion Criteria
* Patients not able to reason
* Age \<18 or \>80 years
* Claustrophobia
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Medical University of Graz
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Stefan Wolfsberger, Prof.
Role: PRINCIPAL_INVESTIGATOR
Medical University of Graz
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Medical University of Graz
Graz, Styria, Austria
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
35-046 ex 22/23
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.