"The Effect of the Use of an Autotransfusion Device on Hemodynamic Parameters During Resuscitation".

NCT ID: NCT06153160

Last Updated: 2025-03-30

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

24 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-11-22

Study Completion Date

2025-03-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of the research (pilot study) is to determine the impact of the use of the autotransfusion device on hemodynamic parameters during resuscitation.

24 people will be included in the pilot study (12 people will be included in the intervention group - with the usage of "autotransfusion socks" during resuscitation and 12 people in the control group - without "autotransfusion socks"). Investigators will compare the hemodynamic parameters and also neurological outcome between both groups.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The purpose of the research (pilot study) is to determine the impact of the use of the autotransfusion device on hemodynamic parameters during resuscitation.

Out-of-hospital cardiac arrest (OHCA) is one of the leading causes of death in Europe.

In order to improve the hemodynamic parameters during resuscitation, device for autotransfusion was developed. Devices are basically a very strong elastic stockings that also block arterial circulation. While "putting on" stockings, blood is being squeezed from the lower extremities (approximately 500 ml of blood for each lower limb). With blood being squeezed from the lower limb into the central circulation the filling of the heart is being improved; thus the device will improve the preload and also cardiac output.

A study done on an animal model showed that during resuscitation using "autotransfusion socks" increases both systolic and diastolic blood pressure during resuscitation, the perfusion of the coronary arteries improves and also the values of the partial pressure of carbon dioxide increases.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Out of Hospital Cardiac Arrest Cardiac Arrest

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients with HemaShock device

12 patients in cardiac arrest will receive HemaShock device during resuscitation.

All other interventions will be made following guidelines.

Group Type EXPERIMENTAL

HemaShock device

Intervention Type DEVICE

The HemaShock is a tight silicone ring attached to a pressure stocking. It comes wrapped into a doughnut and has a set of handles. The operator simply puts the doughnut over the foot or hand, and pulls on the handles to unravel the HemaShock while applying pressure throughout the appendage. The device displace blood from limbs to central blood system, thus improving preload and cardiac output.

Patients with-out HemaShock device

12 patients in cardiac arrest will not receive HemaShock device during resuscitation.

All other interventions will be made following guidelines.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

HemaShock device

The HemaShock is a tight silicone ring attached to a pressure stocking. It comes wrapped into a doughnut and has a set of handles. The operator simply puts the doughnut over the foot or hand, and pulls on the handles to unravel the HemaShock while applying pressure throughout the appendage. The device displace blood from limbs to central blood system, thus improving preload and cardiac output.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* OHCA (Out of Hospital Cardiac Arrest)
* age \> 18 years
* intubated
* meets criteria for resuscitation

Exclusion Criteria

* age \< 18 years
* not intubated
* clinical signs for DVT (deep vein thrombosis), PE (pulmonary embolism)
* clinical signs of acute inflammation of limbs, broken limbs etc.
* known oncological patient
* asphyxia
* trauma patients
Minimum Eligible Age

18 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

OHK Medical Devices

UNKNOWN

Sponsor Role collaborator

University Medical Centre Maribor

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Maribor University Medical Centre

Maribor, Maribor City Municipality, Slovenia

Site Status

Community health center Maribor, Prehospital unit

Maribor, , Slovenia

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Slovenia

References

Explore related publications, articles, or registry entries linked to this study.

Boyce LW, Vliet Vlieland TP, Bosch J, Wolterbeek R, Volker G, van Exel HJ, Heringhaus C, Schalij MJ, Goossens PH. High survival rate of 43% in out-of-hospital cardiac arrest patients in an optimised chain of survival. Neth Heart J. 2015 Jan;23(1):20-5. doi: 10.1007/s12471-014-0617-x.

Reference Type BACKGROUND
PMID: 25326102 (View on PubMed)

Olasveengen TM, Semeraro F, Ristagno G, Castren M, Handley A, Kuzovlev A, Monsieurs KG, Raffay V, Smyth M, Soar J, Svavarsdottir H, Perkins GD. European Resuscitation Council Guidelines 2021: Basic Life Support. Resuscitation. 2021 Apr;161:98-114. doi: 10.1016/j.resuscitation.2021.02.009. Epub 2021 Mar 24.

Reference Type BACKGROUND
PMID: 33773835 (View on PubMed)

Soar J, Bottiger BW, Carli P, Couper K, Deakin CD, Djarv T, Lott C, Olasveengen T, Paal P, Pellis T, Perkins GD, Sandroni C, Nolan JP. European Resuscitation Council Guidelines 2021: Adult advanced life support. Resuscitation. 2021 Apr;161:115-151. doi: 10.1016/j.resuscitation.2021.02.010. Epub 2021 Mar 24.

Reference Type BACKGROUND
PMID: 33773825 (View on PubMed)

Aminiahidashti H, Shafiee S, Zamani Kiasari A, Sazgar M. Applications of End-Tidal Carbon Dioxide (ETCO2) Monitoring in Emergency Department; a Narrative Review. Emerg (Tehran). 2018;6(1):e5. Epub 2018 Jan 15.

Reference Type BACKGROUND
PMID: 29503830 (View on PubMed)

Yang Z, Tang D, Wu X, Hu X, Xu J, Qian J, Yang M, Tang W. A tourniquet assisted cardiopulmonary resuscitation augments myocardial perfusion in a porcine model of cardiac arrest. Resuscitation. 2015 Jan;86:49-53. doi: 10.1016/j.resuscitation.2014.10.009. Epub 2014 Oct 23.

Reference Type BACKGROUND
PMID: 25447436 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

HemaShock socks

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

V-CPR Under Special Circumstances
NCT07101510 COMPLETED NA
Ventilation Monitoring in OHCA
NCT04988906 COMPLETED NA
Automated Real-time Feedback on CPR Study
NCT00539539 COMPLETED PHASE2