Diagnostic Accuracy Study of a Point-of-Care Test for Coagulation Function
NCT ID: NCT06037720
Last Updated: 2023-09-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
50 participants
OBSERVATIONAL
2023-09-30
2024-01-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Objective: To analyze the accuracy between the point-of-care diagnostic method and the laboratory test considered the gold standard for checking the INR.
Methodology: Cross-sectional study of diagnostic accuracy with simultaneous testing of the Coaguchek XS device and standard laboratory method in patients undergoing cardiopulmonary bypass to evaluate INR results.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of TEG 6S PM® During Cardiopulmonary Bypass to Detect Postoperative Biological Coagulopathy
NCT06230640
Interchangeability of Arterial Coagulation and Venous Coagulation, in the Context of Cardiac Surgeries Under Cardiopulmonary Bypass, Using the DMDiv Hemochron Signature Elite
NCT05875272
Comparing Point of Care Clotting Tests in the OR Versus Standard Laboratory Clotting Tests
NCT00892905
Kidney Function in Diabetics During CPB (Cardio Pulmonary Bypass)
NCT03405532
Quantification of Thrombocytes Number and Function in Patients Undergoing Prolonged Extracorporeal Circulation
NCT02771223
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The prothrombin time (PT) is a general assessment of the integrity of the extrinsic and common pathway of coagulation. It determines the time of formation of the fibrin clot. The INR/RNI (International Normalized Ratio) is calculated from the PT and is intended to establish valid comparisons regardless of the type of PT reagent (known as thromboplastin) used by different clinical laboratories. The INR is indicated for evaluating the integrity of the extrinsic (factor VII\*) and common pathway (fibrinogen and factors II\*, V and X\*), and for monitoring the anticoagulant effect of an anti-vitamin K agent (warfarin), capable of inhibiting the synthesis of vitamin K dependent factors (II, VII, IX, X, proteins C and S).
Today, due to its safety, sensitivity and speed, the thromboelastogram is recommended as the method of choice for assessing hemostasis in a surgical setting. However, because it is still not widespread in many centers, mainly due to its high cost, many hospitals are limited to the use of traditional laboratory methods which, despite their undeniable reliability, require more time for their execution and release of results.
In cardiac surgery with cardiopulmonary bypass (CPB), the use of prime solution to fill the CPB circuit results in hemodilution of coagulation factors, with factor I (fibrinogen) being one of the most affected, but not the only one. Each abnormality detected requires a specific action. Thus, the activated clotting time (ACT) is normalized with the administration of protamine. Thrombocytopenia and/or platelet dysfunction, with platelet concentrate infusion. Abnormalities in clotting factors, with administration of the specific factor, eg fibrinogen, either by factor concentrate, cryoprecipitate or plasma. It is at this moment that a quick assessment of hemostasis, in a global and individualized way at the same time, is necessary.
More than a decade ago, devices appeared on the market designed to help patients using warfarin to maintain their anticoagulation within parameters established for each case, providing safety, speed and comfort. Using a reagent strip and a drop of blood, evaluating the INR has become as simple as evaluating capillary blood glucose for diabetic patients. In just a few seconds, INR assessment can show significant changes in the extrinsic coagulation pathway, an important step to help with rapid decision-making in surgical environments. The Coaguchek Device, validated and used for outpatient management of patients using Warfarin, presents valuable characteristics for this purpose (simplicity, speed, safety), also important in the context of intraoperative decision-making. There are few reports in the literature on the use of the Coaguchek device in surgery and on the reliability of the data obtained through its use.
To evaluate this correlation, the main objective of the present study is to evaluate the effectiveness of the portable INR meter in a surgical setting and comparing it with conventional laboratory methods. The proposal is a cross-sectional diagnostic study in patients scheduled electively to undergo cardiac surgery with cardiopulmonary bypass at Hospital de Base in the Federal District.
All patients will receive standard monitoring associated with hemodynamic monitoring with invasive blood pressure and central venous access. Balanced general inhalation anesthesia will be administered to all patients. Hemodynamic support with dobutamine, noradrenaline, nitroprusside, nitroglycerin, vasopressin, or milrinone will be offered according to perioperative needs. The same commercial brand of heparin and protamine will be used to all the patients.
Laboratory tests, including samples for the Coaguchek device strip, will be collected 10 minutes before heparin administration and 10 minutes after the end of the protamine infusion. The laboratory exams that will be collected are: arterial blood gases, venous blood gases, electrolytes, complete blood count, coagulogram (TAP, aPTT, INR) and fibrinogen.
The sample size was calculated for the limits of agreement by Bland and Altman (1986)1, according to the method developed by Lu et al. (2016).2 Based on previous studies3-5, we assumed a mean difference between the POC test and the laboratory test of 0.126 units with a standard deviation of 0.132. Furthermore, based on clinical criteria, we consider that an absolute difference greater than 0.5 units will be clinically relevant. In other words, the maximum difference (Δ) between the tests (so as not to change the clinical approach) would be up to ± 0.5 units; that is, (-Δ ,Δ) equals (-0.5,0.5). Assuming a 5% ɑ level and 95% confidence intervals around the Bland-Altman limits of agreement, 43 participants were needed to ensure a statistical power of 90% to detect agreement between the two methods. All calculations were performed using the Stata 16 program (StataCorp, Texas, United States). We decided to increase the sample to 50 patients for cases of loss to follow-up or failures in annotations.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CROSSOVER
CROSS_SECTIONAL
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Coaguchek testing
Patients scheduled electively to undergo cardiac surgery with cardiopulmonary bypass at Hospital de Base in the Federal District.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* admitted to the Hospital de Base of the Federal District for cardiac surgery, who volunteered to participate in the examination both by the traditional method of venous INR examination and by the use of the Coaguchek device and only after signing the TCLE.
* patients who refuse to participate in the study
* patients with kidney, liver, hematological disease or any disease that affects coagulation
* patients participating in other studies
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hospital de Base
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Fabricio Tavares Mendonca
MD, MSc, PhD
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
References
Explore related publications, articles, or registry entries linked to this study.
Khalaf-Adeli E, Alavi M, Alizadeh-Ghavidel A, Pourfathollah AA. Comparison of standard coagulation testing with thromboelastometry tests in cardiac surgery. J Cardiovasc Thorac Res. 2019;11(4):300-304. doi: 10.15171/jcvtr.2019.48. Epub 2019 Oct 13.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PeriopCoaguChek
Identifier Type: -