Quantra vs TEG for Congenital Cardiac Surgery - a Pilot Validation Study
NCT ID: NCT05295693
Last Updated: 2025-05-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
40 participants
OBSERVATIONAL
2022-10-13
2023-05-25
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The current testing device used at our institution is the "TEG 5000" (Haemonetics Corporation). The novel coagulation testing device "Quantra System" (Hemosonics) has favorable properties (result within 20 minutes) allowing for a quicker identification of the coagulation problem and hence faster administration of the correct coagulation products, potentially leading to better coagulation quality and possibly reducing the need of additional blood products. The aim of this prospective observational (non-interventional, investigational only) quality improvement study is to investigate if the Quantra is reliable and valid in predicting the coagulation status when compared with our standard-of-care device TEG 5000.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
TEG 6s® for Perioperative Monitoring of Platelet Function During Cardiopulmonary Bypass for Cardiac Surgery
NCT04746560
Evaluation of TEG 6S PM® During Cardiopulmonary Bypass to Detect Postoperative Biological Coagulopathy
NCT06230640
Intraoperative Echocardiography in Low-Risk CABG Surgery
NCT06154265
HemoSonics - UTMB Cardiac Surgery Study
NCT03988465
Diagnostic Accuracy Study of a Point-of-Care Test for Coagulation Function
NCT06037720
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The current testing device used at our institution during congenital heart surgery on CPB is the TEG 5000 (Haemonetics Corporation). Prior to separation from CPB (mostly 30-60 minutes) and after the first coagulation products were given (approx. 60 minutes after separation from CPB) a Clauss Fibrinogen and a TEG are drawn. These samples are sent to an off-site lab for processing and time to result ranges from 60-90 minutes. Therefore, results are often not present when needed.
An easy to use point-of-care (POC) test device being readily available in the operation room and allowing for rapid results could result in quicker identification of the coagulation problem and hence allow for faster administration of the correct coagulation products, potentially leading to better coagulation quality and possibly reducing the need of additional blood products.
The Quantra System (Hemosonics) is an easy-to-use, stand-alone device presenting results within 20 minutes. With these properties all above mentioned problems would be addressed. To date the Quantra has not been used and has not been evaluated in patients with congenital heart disease for cardiac surgery on CPB.
The aim of this prospective observational (non-interventional, investigational only) quality improvement study is to investigate if the Quantra is reliable and valid in predicting the coagulation status when compared with our standard-of-care device TEG
All patients who are enrolled in this study will be patients who are scheduled to undergo cardiac surgery and who require a general anesthesia, endotracheal intubation, arterial line placement and coagulation testing as part of standard of care for the surgery.
No patient will have a general anesthesia, endotracheal intubation, arterial line inserted or coagulation testing for research purposes only.
If the family/patient consent to be enrolled in the study the patient will be included in the study. It is standard of care to draw blood samples for coagulation testing (TEG and Clauss Fibrinogen) prior to separation of cardio-pulmonary-bypass (t1) and after the first coagulation products were given (t2), resulting in 2 x 5.4mL of blood.
For testing of efficacy/reliability/validity of the Quantra System we will need to draw additional blood samples (2.7mL) for each time point t1 and t2, resulting in a total of 2 x 2.7mL. These extra 5.4mL of blood drawn during the research portion of this study is additional to what they need for the surgical procedure and is not standard of care.
No clinical decision will be made on the results of the Quantra System. This is an investigational, non-interventional study.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Correlation of the Quantra with the TEG
The purpose of this study is to evaluate the efficacy/reliability/validity of the Quantra device in patients with congenital heart disease for cardiac surgery on CPB.
The study if of investigational interest only. No clinical decisions will be made based on the results obtained by the Quantra device.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
* Bodyweight under 3kg
8 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Stanford University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Alexander R Schmidt, MD
Role: PRINCIPAL_INVESTIGATOR
Stanford University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Stanford University
Palo Alto, California, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Ochocinski D, Navaratnam M, Babb A, De Souza E, Kamra K, Sleasman JR, Margetson TD, Bhamidipati JK, Ramamoorthy C, Schmidt AR. Comparison of the Point-Of-Care Coagulation Device Quantra With the TEG-5000 for Congenital Cardiac Surgery-A Pilot Study. Paediatr Anaesth. 2025 Jun;35(6):469-480. doi: 10.1111/pan.15097. Epub 2025 Mar 17.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Quantra vs TEG
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.