Quantra vs TEG for Congenital Cardiac Surgery - a Pilot Validation Study

NCT ID: NCT05295693

Last Updated: 2025-05-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

40 participants

Study Classification

OBSERVATIONAL

Study Start Date

2022-10-13

Study Completion Date

2023-05-25

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Congenital heart surgery on cardio-pulmonary bypass (CPB) is associated with impacted coagulation quality and increased bleeding after separation of CPB.

The current testing device used at our institution is the "TEG 5000" (Haemonetics Corporation). The novel coagulation testing device "Quantra System" (Hemosonics) has favorable properties (result within 20 minutes) allowing for a quicker identification of the coagulation problem and hence faster administration of the correct coagulation products, potentially leading to better coagulation quality and possibly reducing the need of additional blood products. The aim of this prospective observational (non-interventional, investigational only) quality improvement study is to investigate if the Quantra is reliable and valid in predicting the coagulation status when compared with our standard-of-care device TEG 5000.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Congenital heart surgery on cardio-pulmonary bypass (CPB) is associated with impacted coagulation quality and increased bleeding after separation of CPB. Therefore, coagulation products and blood products often need to be given/transfused during these cases. The correct choice and dosing of coagulation products is essential to effectively stop bleeding and reduce the need of additional blood transfusion.

The current testing device used at our institution during congenital heart surgery on CPB is the TEG 5000 (Haemonetics Corporation). Prior to separation from CPB (mostly 30-60 minutes) and after the first coagulation products were given (approx. 60 minutes after separation from CPB) a Clauss Fibrinogen and a TEG are drawn. These samples are sent to an off-site lab for processing and time to result ranges from 60-90 minutes. Therefore, results are often not present when needed.

An easy to use point-of-care (POC) test device being readily available in the operation room and allowing for rapid results could result in quicker identification of the coagulation problem and hence allow for faster administration of the correct coagulation products, potentially leading to better coagulation quality and possibly reducing the need of additional blood products.

The Quantra System (Hemosonics) is an easy-to-use, stand-alone device presenting results within 20 minutes. With these properties all above mentioned problems would be addressed. To date the Quantra has not been used and has not been evaluated in patients with congenital heart disease for cardiac surgery on CPB.

The aim of this prospective observational (non-interventional, investigational only) quality improvement study is to investigate if the Quantra is reliable and valid in predicting the coagulation status when compared with our standard-of-care device TEG

All patients who are enrolled in this study will be patients who are scheduled to undergo cardiac surgery and who require a general anesthesia, endotracheal intubation, arterial line placement and coagulation testing as part of standard of care for the surgery.

No patient will have a general anesthesia, endotracheal intubation, arterial line inserted or coagulation testing for research purposes only.

If the family/patient consent to be enrolled in the study the patient will be included in the study. It is standard of care to draw blood samples for coagulation testing (TEG and Clauss Fibrinogen) prior to separation of cardio-pulmonary-bypass (t1) and after the first coagulation products were given (t2), resulting in 2 x 5.4mL of blood.

For testing of efficacy/reliability/validity of the Quantra System we will need to draw additional blood samples (2.7mL) for each time point t1 and t2, resulting in a total of 2 x 2.7mL. These extra 5.4mL of blood drawn during the research portion of this study is additional to what they need for the surgical procedure and is not standard of care.

No clinical decision will be made on the results of the Quantra System. This is an investigational, non-interventional study.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coagulopathy

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Correlation of the Quantra with the TEG

The purpose of this study is to evaluate the efficacy/reliability/validity of the Quantra device in patients with congenital heart disease for cardiac surgery on CPB.

The study if of investigational interest only. No clinical decisions will be made based on the results obtained by the Quantra device.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* All cases with hypothermia (\<=30C)

Exclusion Criteria

* Neonatal/Infant Bloodless surgery
* Bodyweight under 3kg
Maximum Eligible Age

8 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Stanford University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Alexander R Schmidt, MD

Role: PRINCIPAL_INVESTIGATOR

Stanford University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Stanford University

Palo Alto, California, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Ochocinski D, Navaratnam M, Babb A, De Souza E, Kamra K, Sleasman JR, Margetson TD, Bhamidipati JK, Ramamoorthy C, Schmidt AR. Comparison of the Point-Of-Care Coagulation Device Quantra With the TEG-5000 for Congenital Cardiac Surgery-A Pilot Study. Paediatr Anaesth. 2025 Jun;35(6):469-480. doi: 10.1111/pan.15097. Epub 2025 Mar 17.

Reference Type RESULT
PMID: 40095320 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Quantra vs TEG

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Thrombin in Cardiac Surgery
NCT04762576 UNKNOWN