The Relationship Between Lower Limb Functionality, Knee Joint Position Sense, Balance and Falls in Haemiplegic Patients

NCT ID: NCT05973279

Last Updated: 2023-09-07

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

60 participants

Study Classification

OBSERVATIONAL

Study Start Date

2023-09-01

Study Completion Date

2024-06-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Stroke is defined as a neurological disorder attributed to acute focal damage of the central nervous system from a vascular cause, including cerebral infarction, intracerebral haemorrhage and subarachnoid haemorrhage. The World Health Organisation defines stroke as a focal and sometimes global impairment of cerebral function that lasts longer than 24 hours or ends in death, develops rapidly, has no demonstrable cause other than a vascular cause. Evaluation of muscle strength and balance ability of affected patients is critical for the recovery of lower extremity motor functions.

Proprioception encompasses various sensory perception modalities such as force, effort, movement and limb position. Impairment of sensory function in patients with haemiplegia can hinder the ability of muscles to recover during walking. Accurate and effective assessment of gait and balance functions and their subsequent improvement is one of the primary goals of stroke rehabilitation programmes. Studies comparing the effects of lower extremity functionality and knee joint position sense on balance and falls are available in various versions in the literature. However, there is no study in which 'Restorative Therapies RT300 leg/arm/cor' device was used to measure functionality, 'Humac Norm Isokinetic Machine' was used to measure knee joint position sense, and 'Tecno Body Prokin Isokinetic Balance System' was used to measure balance in a single simultaneous study. Therefore, the aim of this study was to investigate the relationship between lower limb functionality and knee joint position sense with balance and fall parameters in patients with hemiplegia using various devices.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Haemiplegic Patients Balance Knee Joint Position Sensation Lower Limb Functionality

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

OTHER

Study Time Perspective

OTHER

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Hemiplegic patients

Tecno Body Prokin Isokinetic Balance System

Intervention Type OTHER

It provides objectively measurable data in static and dynamic balance measurements. The moving balance platform of the system, which is driven by air piston servo motors, can measure at a working angle of 15 degrees in all directions. The results can be monitored and recorded live on the screen on the device. From these data, each individual's static and dynamic balance score is obtained by summing the forward-backward standard deviation and right-left standard deviation.

Restorative Therapies RT300 leg/arm/cor:

Intervention Type OTHER

RT300 is a motorised treatment system. In general there are 3 systems; Passive therapy, Active therapy and a combination of active therapy with some assistance from the motor. The device can be used from a chair, wheelchair or bed and there are two variants that can be used separately; Leg system, Arm system. Electrodes placed on the skin over specific muscle groups are connected via a cable or wirelessly to the RT300. These are used to stimulate peripheral motor nerves, causing the muscles to work. The software of the SAGE controller unit of the RT300 monitors the treatment process, including the stimulation patterns sent to the arms or legs, and the operation of the ergometer motor to produce smooth cycling motion. Contraindicated in the presence of lower limb fractures or pregnancy.

CSMI (CYBEX) Humac Norm Isokinetic Test and Exercise System

Intervention Type OTHER

22 isolated joint movement models, 4 resistance modes (isokinetic, isotonic, isometric and passive) and a large number of reports to meet the measurement and exercise needs of today's clinicians and researchers. The exercise modes of the device include; Continuous passive movement, multi-angle isometry, proprioception training, standard and eccentric focused isokinetic strengthening, deceleration training, dynamic isotonic training, strength training. Test modes of the device include; Proprioceptive, co-measured, standard isokinetic, concentric/eccentric isokinetic, intermittent stroke isokinetic test.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tecno Body Prokin Isokinetic Balance System

It provides objectively measurable data in static and dynamic balance measurements. The moving balance platform of the system, which is driven by air piston servo motors, can measure at a working angle of 15 degrees in all directions. The results can be monitored and recorded live on the screen on the device. From these data, each individual's static and dynamic balance score is obtained by summing the forward-backward standard deviation and right-left standard deviation.

Intervention Type OTHER

Restorative Therapies RT300 leg/arm/cor:

RT300 is a motorised treatment system. In general there are 3 systems; Passive therapy, Active therapy and a combination of active therapy with some assistance from the motor. The device can be used from a chair, wheelchair or bed and there are two variants that can be used separately; Leg system, Arm system. Electrodes placed on the skin over specific muscle groups are connected via a cable or wirelessly to the RT300. These are used to stimulate peripheral motor nerves, causing the muscles to work. The software of the SAGE controller unit of the RT300 monitors the treatment process, including the stimulation patterns sent to the arms or legs, and the operation of the ergometer motor to produce smooth cycling motion. Contraindicated in the presence of lower limb fractures or pregnancy.

Intervention Type OTHER

CSMI (CYBEX) Humac Norm Isokinetic Test and Exercise System

22 isolated joint movement models, 4 resistance modes (isokinetic, isotonic, isometric and passive) and a large number of reports to meet the measurement and exercise needs of today's clinicians and researchers. The exercise modes of the device include; Continuous passive movement, multi-angle isometry, proprioception training, standard and eccentric focused isokinetic strengthening, deceleration training, dynamic isotonic training, strength training. Test modes of the device include; Proprioceptive, co-measured, standard isokinetic, concentric/eccentric isokinetic, intermittent stroke isokinetic test.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Individuals over 18 years of age
* Volunteering to participate in the study

Exclusion Criteria

* Hip and knee prosthesis
* Being diagnosed with vertigo
* Having a history of serious neurological diseases such as Parkinson's disease, multiple sclerosis except hemiplegia
* Having a previous operation for the lower limb
* Poor co-operation
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Bolu Izzet Baysal Physiotherapy and Rehabilitation Training and Research Hospital

UNKNOWN

Sponsor Role collaborator

Karabuk University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Fatma Hale Altınkaya

INVESTIGATOR

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Adnan Demirel

Role: STUDY_DIRECTOR

Izzet Baysal Physiotherapy and Rehabilitation Training and Research Hospital

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Fatma Hale Altınkaya

Role: CONTACT

05312013899

Tarık Ozmen

Role: CONTACT

05063028740

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

KarabukUNI

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.