Efficacy and Safety of Hemostatic Methods in Distal Radial Artery Approach for Cardiac Catheterization
NCT ID: NCT05966376
Last Updated: 2023-09-21
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
482 participants
INTERVENTIONAL
2022-02-01
2023-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Transradial Versus Transulnar Artery Approach for Coronary Interventions
NCT01364532
The Procedural Success and Complication Rate of the Left Distal Radial Approach
NCT03292367
Effect of Reactive Hyperemia and Ultrasound-guided Puncture on the Success Rate of Radial Artery Cannulation (RadialHUS)
NCT05364463
Comparison of the Proximal Approach and Distal Approach of Axillary Vein Catheterization Under Ultrasound Guidance
NCT03395691
Intravascular ECG During Insertion of Peripheral Inserted Central-venous Catheters: Replacement for Chest X-ray?
NCT03197246
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Distal radial access at the level of the anatomical snuffbox and dorsal region of the hand has currently positioned itself as a viable and safe approach for procedures in interventional cardiology, whether diagnostic, simple, or complex angioplasties. We know that this approach method mainly reduces the occlusion rate of the proximal radial artery, among other advantages; however, we still do not have scientific evidence on the various hemostasis methods for this approach. Practice varies between centers and countries and hemostasis methods vary from an elastic compression bandage to the use of devices manufactured specifically for this approach such as the PreludeSYNC DISTAL or modification of devices manufactured for proximal radial hemostasis such as the TR band. In this clinical trial, we intend to analyze the efficacy and safety of two hemostasis methods in patients who require an interventional procedure (PredludeSYNC DISTAL vs modified TR band), to date, there is no clinical trial that compares these methods face to-face in relation to their efficacy and safety. Retrospective studies indicate that both methods are effective in reducing radial artery occlusion and are safe in reducing the bleeding/hematoma rate.
THE PURPOSE OF THE STUDY To compare the efficacy (distal radial artery occlusion) and safety (hematoma/bleeding) of two devices of distal radial hemostasis (PreludeSYNC distal and TR band) in patients undergoing percutaneous coronary intervention.
STUDY DESIGN Experimental, randomized, prospective, longitudinal, prolective, and comparative.
SUBJECTS OF STUDY Patients from the Ignacio Chávez National Institute of Cardiology who will undergo distal radial percutaneous coronary intervention/angiography.
METHODOLOGY After signing the informed consent, patients will be randomized by balanced block methods to: 1) Hemostasis using the PreludeSYNC distal device, or 2) Hemostasis using the Modified Radial Band device.
PRIMARY OUTCOME To compare the efficacy (distal radial artery occlusion) and safety (hematoma/bleeding) of PreludeSYNC distal versus Modified Terumo Radial Band in distal radial approach.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Modified Terumo Radial Band
A standard hemostatic device used for proximal radial approach. The hard plastic component is removed to achieve better attachment in the distal radial approach.
* Clean and dry the puncture site.
* The introducer is withdrawn 2 cm.
* Place the device on the patient's hand depending on the approach side.
* Terumo logo is positioned toward the little finger side.
* The green mark is positioned 1 cm proximal to the puncture site.
* The bands are adjusted and fixed around the wrist.
* The Terumo syringe is filled with 15 ml of air.
* The balloon of the device is slowly inflated through the valve while the introducer is slowly withdrawn simultaneously.
* Once the introducer is completely withdrawn, the balloon continues to be inflated until the absence of bleeding is verified.
* Once hemostasis is achieved, the patient must be able to move his fingers and wrist without bleeding. If bleeding is observed, the balloon is inflated to achieve adequate hemostasis.
Hemostatic device for distal radial approach.
Hemostasis after distal radial approach is done with one of two devices, one of them is designed specifically for the distal radial approach; the other is not but a modified technique with the last one could be helpful.
PreludeSYNC distal
A specific hemostatic device, designed for distal radial approach.
* Clean and dry the puncture site.
* Selection and preparation of the PreludeSYNC distal device according to the approach side.
* The introducer is withdrawn 2cm.
* The hemostasis device is placed on the patient's hand.
* Bands position: 1) little finger side; 2) thumb side; 3) between the thumb and the index finger.
* The circular mark of the balloon is positioned 1cm proximal to the puncture site.
* Bands are adjusted and fixed.
* The syringe is filled with 10 ml of air.
* The balloon of the device is slowly inflated while the introducer is slowly withdrawn simultaneously.
* Once the introducer is completely withdrawn, the balloon continues to be inflated until the absence of bleeding is verified.
* Once hemostasis is achieved, the patient must be able to move his fingers and wrist without bleeding. If bleeding is observed, the balloon should be inflated to achieve adequate hemostasis.
Hemostatic device for distal radial approach.
Hemostasis after distal radial approach is done with one of two devices, one of them is designed specifically for the distal radial approach; the other is not but a modified technique with the last one could be helpful.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Hemostatic device for distal radial approach.
Hemostasis after distal radial approach is done with one of two devices, one of them is designed specifically for the distal radial approach; the other is not but a modified technique with the last one could be helpful.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Cardiovascular disease that requires coronary angiography in its approach.
Exclusion Criteria
* Lesions in venous or arterial hemoducts.
* Impossibility to provide informed consent.
* Chronic kidney disease on hemodialysis through arteriovenous fistula at the same site where the approach is planned.
* Severe chronic renal failure (GFR less than 30 ml/min/m2)
* Patients diagnosed with cancer.
* Patient with rheumatological and hematological pro-thrombotic disorders.
* Non-hydrophilic radial introducer.
* Failed cannulation of the radial artery with an introducer.
* Successful trans-radial access that is crossed over to the femoral approach.
* Patients with an interventional procedure using a radial approach in the previous 30 days.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Instituto Nacional de Cardiologia Ignacio Chavez
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Arnoldo Enmanuel Loáisiga Sáenz
Interventional Cardiology
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Instituto Nacional de Cardiologia Ignacio Chávez
Mexico City, , Mexico
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
21-1255
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.