Self-invented Intracavitary ECG Wire VS the Commercial System - Certodyn®
NCT ID: NCT03697291
Last Updated: 2018-10-09
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
36 participants
INTERVENTIONAL
2018-08-01
2019-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Intracavitary ECG are proven effective for tip confirmation and provide some benefits i.e. lower cost, decrease exposure to harmful radiation for care providers and also the patients, require less personals and equipments, provide real-time confirmation as comparable to fluoroscopy, etc. There are several devices and makes of iECG apparatus but B.Braun-Certodyn® remains the only available system in our institution. The limitation is the availability of the Certodyn devices on each locations where CVL will be placed i.e. operating theater, intensive care unit, bedside placement, radiology suite, etc. Since the connecting wire is only supplied in the certain CVL kits under B.Braun brand, this has rendered iECG for other types or makes of CVL or PICC line become even more difficult.
Self-invented connector wire for iECG (PS wire) has been made and used effectively in the past few years at Siriraj hospital. The patent registration is underway and the author seek to compare this PS wire against the commercial Certodyn system.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Application of Intracavity Electrocardiogram Positioning Technique in PICC
NCT05555160
Non-Inferiority Study to Compare the Effectiveness of the Seldinger Over-the-Wire Technique and the Modified Seldinger Technique
NCT04303052
Siting Central Venous Catheters Precisely While Performing the Access Procedure
NCT05751395
Intravascular ECG During Insertion of Peripheral Inserted Central-venous Catheters: Replacement for Chest X-ray?
NCT03197246
A Study to Assess Placement and Confirmation of Peripheral Inserted Central Catheters Tip Position Using a New Electrocardiographic Method
NCT01969981
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
1. To evaluate the success rate of iECG CVL tip confirmation by self-invented iECG connector wire.
2. To compare quality of iECG tracing produced from both of self-invented iECG wire versus the Certodyn system.
Materials, participants and study method
Equipments required:
1\) Self-invented iECG wire (PS wire) 2) Commercial iECG system which consists of the Certodyn and the wire. 3) Standard ECG monitoring system which can display and printout the ECG tracing. 4) A digital ECG caliper which can measure P wave amplitude and noise segment in millimeter up to 2 decimal points. Study method
1. Patient presented for PICC line from upper torso will be screened and assessed for eligibility.
2. Exclusion criteria includes children younger than 18 yo, patient with atrial fibrillation or other rhythms not generated from intrinsic SA node i.e. pacer, unstable hemodynamic, patient with history arrhythmias, HR \> 120 bpm, patients with hypercoagulable state, allergy to heparin or patients with known heparin induced thrombocytopenia, patients with known Creutzfeldt-Jakob Disease
3. Obtain informed consent.
4. Patient will be monitored with standard 3-lead ECG, the baseline lead II ECG will be printed out and tagged with a serial number.
5. Patient will undergo the standard PICC line placement using Seldinger or modified Seldinger technique. The catheter will be pre-flushed with 10 units/mL heparinized NSS. When catheter is inserted into the proximal SVC (guided by landmark measurement), the wire will be retracted to the marked location where the tip of the wire is at the end of the catheter. The iECG connection by Certodyn will be applied. The catheter and wire will be adjusted until the giant P wave (highest P) was detected on screen, this ECG tracing will be printed out and tagged with another non-sequential serial number. The iECG will then switched to the PS wire and the iECG tracing will be printed out again and tagged with another non-sequential serial number. All 3 ECG printouts will be stapled together for measurement by cardiologist who is blind to the intervention later.
6. The intervention related to research study is considered ended at this point. The patient will have their CVL/PICC line adjusted to the proper position (mid to distal SVC for mid-long term and long term catheter). The CVL or PICC will be secured, flushed and locked per standard protocol.
7. Portable CXR will be routinely obtained when patients arrived to the ward. The information of the tip of the catheter will be recorded as well.
Data analysis
1. Demographic data, type of catheter, depth of catheter where giant P wave obtained and final position of catheter will be recorded.
2. Each study patient produce 3 ECG print outs which are -baseline surface lead II ECG
* iECG produced by Certodyn system
* iECG produced by PS wire Each ECG tracing will be evaluated and measured by a cardiologist who is blind to the intervention. The 2 measured parameters includes:
* The amplitude of P wave in mm from baseline surface ECG of each cardiac cycle. -The amplitude of giant P wave in mm from iECG from both Certodyn and PS wire.
3. All 3 ECG print outs will be compared for quality and the length noisy ECG segment (determined as the ECG with interference artifact of baseline \> 1 mm) will also be measured in mm.
6\) All measurement will be analyzed statistically to determine the differences between the 2 systems.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
CROSSOVER
DIAGNOSTIC
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
PS wire
self-invented iECG wire
PS wire
The wiring connection used to convey ECG signal from inside the body
Certodyn
Commercially available iECG system - Certodyn
PS wire
The wiring connection used to convey ECG signal from inside the body
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PS wire
The wiring connection used to convey ECG signal from inside the body
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Requires PICC line insertion from upper torso.
Exclusion Criteria
* Patient with atrial fibrillation or other rhythms not generated from intrinsic SA node i.e. pacer, atrial fibrillation, etc.
* Unstable hemodynamic.
* Patient with history arrhythmias.
* Patient with HR \> 120 bpm.
* Patients with hypercoagulable state.
* Allergy to heparin.
* Patients with known heparin induced thrombocytopenia.
* Patients with known Creutzfeldt-Jakob Disease.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Mahidol University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Prasert Sawasdiwipachai
Principal investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Prasert Sawasdiwipachai, MD
Role: PRINCIPAL_INVESTIGATOR
Anesthesiology department Siriraj hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Siriraj hospital, Mahidol university
Bangkok Noi, Bangkok, Thailand
Department of Anesthesiology, Faculty of Medicine, Siriraj Hospital
Bangkok, , Thailand
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
1. Oster, D.D. "Improving ECG trace quality." Biomedical Instrumentation & Technology, 2000; 34: 219-222. 2. Corsten SA, van Dijk B, Bakker NC, de Lange JJ, Scheffer GJ. Central venous catheter placement using the ECG-guided Cavafix-Certodyn SD catheter. J Clin Anesth. 1994; 6(6): 469-72. 3. Pittiruti M, La Greca A, Scoppettuolo G. The electrocardiographic method for positioning the tip of central venous catheters. J Vasc Access. 2011; 12(4): 280-91. 4. Pittiruti M, Bertollo D, Briglia E, Buononato M, Capozzoli G, De Simone L, La Greca A, Pelagatti C, Sette P. The intracavitory ECG method for positioning the tip of central venous catheters: results of an italian multicenter study. J Vasc Access. 2012; 13(3):357-65. 5. Wang G, Guo L, Jiang B, Huang M, Zhang J, Qin Y. Factors Influencing Intracavitory Electrocardiographic P-Wave Changes during Central Venous Catheter Placement. PLoS One. 201510(4):e0124846. 6. Yuan L, Li R, Meng A, Feng Y, Wu X, Yang Y, et al. Superior success rate of intracavitory electrocardiogram guidance for peripherally inserted central catheter placement in patients with cancer: A randomized open-label controlled multi center study. PLoO One. 2017; 12(3):e0171630.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Si 548/2018
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.