Transfer of Technological Innovations to Nursing Practice: A Contribution to the Prevention of Infections
NCT ID: NCT03563703
Last Updated: 2021-02-08
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
40 participants
INTERVENTIONAL
2018-10-01
2019-12-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Guidelines state that puncture should be attempted only twice per professional, to a maximum of four attempts; against this recommendation and due to the patient's therapeutic needs and clinical situation, health professionals attempt to puncture multiple times in a single scenario. In this regard, health professionals should consider using specific technologies that help to select the vein and reduce the number of puncture attempts and catheter-related mechanical complications. Taking into account the multiplicity of existing technologies in the international market that assist health professionals in peripheral venous catheterization, ultrasound and infrared devices emerge in the literature as two of the most commonly used during this procedure.
These technologies were developed with the purpose of improving peripheral intravenous catheterization success rate and thus reducing the number and extent of the negative effects of multiple or unsuccessful attempts, with the additional purpose of avoiding the frustrations of health professionals in these scenarios. However, such technologies are still underused in clinical practice, since health professionals are not familiar with the use of these devices. Moreover, the costs associated with their purchase and maintenance may be considered as excessive in relation to the traditional method.
The project investigators aim to determine whether the use of either ultrasound or near-infrared vascular imaging will significantly improve the success rate of peripheral intravenous catheterization in adults on first attempt by nurses compared with the standard approach, reduce immediate related complications and improve patient and provider satisfaction.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of the Effectiveness of Ultrasound-guided Techniques and Infrared Illumination, Compared With the Standard Approach to Peripheral Venous Line Placement in People With Difficult Venous Access
NCT06838364
Using a Infrared Thermometer to the Early Detection of Catheter Related Infections
NCT02077816
Ultrasound-guided Peripheral IV vs. Standard Technique in Difficult Vascular Access Patients by ICU Nurses
NCT03745209
Color Doppler and Peripheral Venous Catheters
NCT03889678
Infrared for Peripheral Venous Catheterization in the Critically-ill
NCT03932214
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Ultrasound imaging
Ultrasonography offers visual information about the size and depth of blood vessels, potentially facilitating intravenous placement of the needle in real time.
Ultrasound
Ultrasound allows viewing veins and surrounding anatomical structures, making it easier to perform the placement of a cannula into a peripherally located vein in real time. This process allows the cannulation of veins that are unable to be visualised or palpated.
Near-infrared imaging
Near-infrared imaging devices project near-infrared light onto the skin, which is absorbed by deoxygenated hemoglobin. The invisible image of the underlying vascular pattern is captured by the device, processed and projected, in real time, back onto the patient's skin using visible green light. This technology allows hands-free visualization of a vascular map to guide catheter placement.
Near Infrared Light
Infrared technologies allows illuminating the vein with a near-infrared light, which is absorbed by blood and reflected by adjacent tissue.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ultrasound
Ultrasound allows viewing veins and surrounding anatomical structures, making it easier to perform the placement of a cannula into a peripherally located vein in real time. This process allows the cannulation of veins that are unable to be visualised or palpated.
Near Infrared Light
Infrared technologies allows illuminating the vein with a near-infrared light, which is absorbed by blood and reflected by adjacent tissue.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Participants whose primary nurse agrees to participate in the study;
* Participants who are able to give written assent or oral assent.
Exclusion Criteria
* Participants who are unable to communicate orally and/or in writing.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Unidade Local de Saúde de Coimbra, EPE
OTHER
Associação Portuguesa de Acessos Vasculares
UNKNOWN
Escola Superior de Tecnologia da Saúde de Coimbra
OTHER
Escola Superior de Enfermagem de Coimbra
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Anabela Salgueiro-Oliveira
Ph.D, Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Anabela Salgueiro-Oliveira, Ph.D
Role: PRINCIPAL_INVESTIGATOR
Assistant Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Centro Hospitalar e Universitário de Coimbra
Coimbra, , Portugal
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Marsh N, Webster J, Mihala G, Rickard CM. Devices and dressings to secure peripheral venous catheters to prevent complications. Cochrane Database Syst Rev. 2015 Jun 12;2015(6):CD011070. doi: 10.1002/14651858.CD011070.pub2.
Grune F, Schrappe M, Basten J, Wenchel HM, Tual E, Stutzer H; Cologne Quality Control Network. Phlebitis rate and time kinetics of short peripheral intravenous catheters. Infection. 2004 Feb;32(1):30-2. doi: 10.1007/s15010-004-1037-4.
Pujol M, Hornero A, Saballs M, Argerich MJ, Verdaguer R, Cisnal M, Pena C, Ariza J, Gudiol F. Clinical epidemiology and outcomes of peripheral venous catheter-related bloodstream infections at a university-affiliated hospital. J Hosp Infect. 2007 Sep;67(1):22-9. doi: 10.1016/j.jhin.2007.06.017. Epub 2007 Aug 27.
Abolfotouh MA, Salam M, Bani-Mustafa A, White D, Balkhy HH. Prospective study of incidence and predictors of peripheral intravenous catheter-induced complications. Ther Clin Risk Manag. 2014 Dec 8;10:993-1001. doi: 10.2147/TCRM.S74685. eCollection 2014.
Cicolini G, Manzoli L, Simonetti V, Flacco ME, Comparcini D, Capasso L, Di Baldassarre A, Eltaji Elfarouki G. Phlebitis risk varies by peripheral venous catheter site and increases after 96 hours: a large multi-centre prospective study. J Adv Nurs. 2014 Nov;70(11):2539-49. doi: 10.1111/jan.12403. Epub 2014 Mar 31.
Dorniak-Wall T, Rudaks L, Solanki NS, Greenwood J. Safe and correct use of peripheral intravenous devices. ANZ J Surg. 2013 Oct;83(10):764-8. doi: 10.1111/j.1445-2197.2012.06281.x. Epub 2012 Oct 4.
Ismailoglu EG, Zaybak A, Akarca FK, Kiyan S. The effect of the use of ultrasound in the success of peripheral venous catheterisation. Int Emerg Nurs. 2015 Apr;23(2):89-93. doi: 10.1016/j.ienj.2014.07.010. Epub 2014 Aug 15.
Partovi-Deilami K, Nielsen JK, Moller AM, Nesheim SS, Jorgensen VL. Effect of Ultrasound-Guided Placement of Difficult-to-Place Peripheral Venous Catheters: A Prospective Study of a Training Program for Nurse Anesthetists. AANA J. 2016 Apr;84(2):86-92.
Park JM, Kim MJ, Yim HW, Lee WC, Jeong H, Kim NJ. Utility of near-infrared light devices for pediatric peripheral intravenous cannulation: a systematic review and meta-analysis. Eur J Pediatr. 2016 Dec;175(12):1975-1988. doi: 10.1007/s00431-016-2796-5. Epub 2016 Oct 26.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
TecPrevInf
Identifier Type: -
Identifier Source: org_study_id
More Related Trials