Bipolar Radio-frequency Ablation After Standard Unipolar Approach - Prospective Registry.
NCT ID: NCT05707637
Last Updated: 2025-05-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
100 participants
OBSERVATIONAL
2022-11-02
2026-02-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Aims:
1. To assess how many patients after failed unipolar ablation need redo procedure with bipolar ablation (primary end-point)
2. To assess which intraprocedural electrophysiological parameters predict success during standard unipolar ablation (secondary endpoint)
3. To assess short term efficacy of bipolar ablation (secondary endpoint)
4. To assess one-month efficacy of bipolar ablation (secondary endpoint)
5. To assess which intraprocedural electrophysiological parameters predict success during redo bipolar ablation (secondary endpoint)
6. To evaluate the performance of ECG-based algorithms in predicting the localization / origin of VA, especially of transmural origin (secondary endpoint)
7. To assess the effects of ablation on QoL (secondary endpoint)Methods. The study group consists of all consecutive patients who underwent unipolar ablation of VA originating from the base of the heart in the Grochowski Hospital and collaborating centres. All these patients are referred to Grochowski Hospital for further follow-up and treatment if needed, including bipolar ablation if initial unipolar approach failed. In all patients acute and one-month efficacy of unipolar and bipolar ablation is assessed.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Catheter Cryoablation Versus Antiarrhythmic Drug as First-Line Therapy of Paroxysmal Atrial Fibrillation
NCT01803438
Low-voltage Areas Defragmentation in Sinus Rhythm for Radiofrequency Ablation of Persistent Atrial Fibrillation
NCT04045067
Real Zero Fluoroscopy Catheter Ablation.
NCT03458273
First-time Ablation of Atrial Fibrillation Registry
NCT06381245
Long-term Results of Bilateral Thoracoscopic Ablation for Stand-alone Atrial Fibrillation
NCT05836389
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Unipolar radio-frequency (RF) ablation is a standard approach to treat VA. When it fails, bipolar RF ablation may be an attractive alternative. Using this approach, RF energy travels between the tip of ablation electrode and the tip of another electrode, called return or passive electrode. By proper positioning of the electrodes in two adjacent structures, the site of VA origin may lay between the tips of these electrodes and high density RF current may effectively destroy the tissue responsible for VA. The most frequently used electrode locations for bipolar RF ablation are left pulmonic cusp (LPC), AoCusps, aorto-mitral continuity (AMC) and GCV.
It has been shown in animal model that bipolar ablation causes denser and larger lesions than standard unipolar approach. The lesions are also deeper, more transmural and created without steam pops as compared with unipolar RF ablation. Also, the perpendicular orientation of the electrodes tips as well as irrigated catheters rather than standard catheters are important for bipolar ablation safety and efficacy.
The bipolar approach is usually used when unipolar ablation fails. To date, only case reports and case series have been published showing improved outcome when bipolar ablation was used during redo procedures. However, no prospective registry was performed to establish how many patients with VA originating from the base of the heart require bipolar ablation and which invasive electrophysiological (EP) parameters predict failure of unipolar ablation and the need for bipolar approach. One ongoing registry does include consecutive patients and is heterogenous. In the current guidelines for VT ablation, the bipolar approach is only shortly mentioned as one of new and still experimental approaches. Also the performance of surface ECG criteria to predict intra-mural VA and effects of bipolar ablation of quality of life have not been established.
2\. Hypothesis.
1. Unipolar ablation fails in a mean of 30% (12-75% depending on VA site), consecutive patients with VA originating from the base of the heart and these patients are candidates for bipolar ablation.
2. Local ventricular signal precocity \> 20 ms, unipolar signal without R wave and pace mapping 12/12 predict effective unipolar ablation
3. Local signal precocity, unipolar signal and pace mapping do not predict efficacy of bipolar ablation,
4. Morphology of VA from surface ECG can identify patients with possible intramural localization of arrhythmia origin in whom initial unipolar ablation fails
5. Successful ablation results in improvement of quality of life (QoL) 3. Aim.
a. To assess how many patients after failed unipolar ablation need redo procedure with bipolar ablation (primary end-point) b. To assess which intraprocedural electrophysiological parameters predict success during standard unipolar ablation (secondary endpoint) c. To assess acute efficacy of bipolar ablation (secondary endpoint) d. To assess one-month efficacy of bipolar ablation (secondary endpoint) e. To assess which intraprocedural electrophysiological parameters predict success during redo bipolar ablation (secondary endpoint) f. To evaluate the performance of ECG-based algorithms in predicting the localization / origin of VA, especially of transmural origin (secondary endpoint) g. To assess the effects of ablation on QoL (secondary endpoint) Methods. Patients. The study group consists of all consecutive patients who underwent unipolar ablation of VA originating from the base of the heart in the Grochowski Hospital and collaborating centres. All these patients are referred to Grochowski Hospital for further follow-up and treatment if needed, including bipolar ablation if initial unipolar approach failed.
Electrophysiology study During EP study three EP parameters characterizing potential site for RF application are assessed. If surface ECG suggests right-sided focus - RVOT is firstly explored. If ECG suggests left-sided focus AoCusps, LVOT, GCV and possibly AIV are firstly explored. The EP parameters consist of (1) precocity of local V signal measured as a difference between the onset of the surface QRS complex (in lead with the earliest onset) and the onset of local bipolar V signal, and (2) presence or absence of R wave in the unipolar V signal. The third (3) parameter - pace-mapping, is also performed and expressed in the number of surface ECG leads with concordant pace-induced and spontaneous QRS morphology and also expressed in percentage of pace-matching in each lead, using dedicated software (EP Bard Lab System, US).
Unipolar ablation. Patients undergo ablation in light sedation using fentanyl and midazolam. In case of lack of PVC in patients with a history PVC only, isoproterenol infusion is used to facilitate PVC occurrence. In patients who undergo ablation due to VT, programmed ventricular stimulation is used to induce VT and in case of non-inducibility, isoproterenol infusion is used and programmed ventricular stimulation repeated to induce VT. In these patients stimulation is repeated at the end of procedure.
RF applications are performed at site with best EP parameters. If this ablation fails, no further attempts are made unless another site is almost as good as initial one and V signal exceeds surface QRS onset.
Ablation is considered acutely effective if no sVT is induced or \>90% reduction of PVC or abolition of nsVT (in patients with nsVT) is achieved.
Ablation is considered acutely failed if all possible sites of VA are mapped: RVOT, PA, GCV, LVOT, AoCusp, AMC (mapping of AVI is not obligatory if placing of ablation electrode there is not feasible) and after RF applications VA is present or no applications were made (no place with good EP parameters were found).
All procedures are performed using Smarttouch Thermocool catheter, ablation index and electroanatomical Carto® 3 (Biosense Webster, Diamond Bar, CA, USA) 3D mapping system. The Smartablate or nGEN ablators are used. Energy settings are standard as usually used for various sites, ranging from 20 watts at AoCusps to 40 watts in LVOT. The power, temperature and duration of RF applications may differ between patients according to the clinical needs and circumstances.
Medium-term efficacy of unipolar ablation. Medium-term efficacy of unipolar ablations is based on 24-h Holter ECG performed 1 month after ablation without any antiarrhythmic drugs (beta blockers are allowed). Efficacy is defined as \>90% reduction of PVC (from baseline Holter) and abolition of nsVT (in patients with nsVT before ablation). In patients with sVT - no sVT recurrence during one month.
Bipolar ablation. Bipolar ablation is performed in a patient with failed/unsuccessful initial unipolar ablation during with all accessible sites were mapped and EP parameters collected.
Bipolar ablation is performed using the Osypka and Carto 3 systems. The HAT500 (OSYPKA AG, Rheinfelden, Germany) generator enables to perform bipolar ablation using two ablation catheters. Power levels and impedance are recorded and displayed for both electrodes. Two open-irrigated 3.5mm or 4 mm tip mapping and ablation catheters are inserted in two adjacent locations. One ablation electrode is active and the second ablation catheter is passive (also named as return) catheter and is not visible on the electro-anatomical system screen during RF energy application.
In general, three sites for bipolar system can be used: (1) LPC, (2) GCV with its extension - AIV and (3) LVOT/AoCusps/AMC/MA. The sites for ablation electrodes positioning are chosen based on intracardiac signals (where local signals exceeds the most the onset of the QRS complex), presumed localization of intramural substrate (anatomical approach - focus should be located between the tips of active and return electrode) and safety issues (no coronary artery between the tips of electrodes based on repeated coronary angiography). Thus, the possible configurations include (1) LPC → LVOT/AoCusps/AMC/MA, (2) GCV → LVOT/AoCusps/AMC/MA or (3) LPC → GCV.
Optimal energy settings for bipolar ablation have not been yet established and are adjusted to the actual needs for effective and safe RF applications in a given patient.
Medium-term efficacy of bipolar ablation. Acute and long-term efficacy are the same as for unipolar ablation.
Coronary artery angiography. Coronary artery angiography is performed routinely during bipolar ablation and in selected patients undergoing unipolar approach (as needed). The radial or femoral artery access is used to enable repetitive contrast injections into the coronary vessels.
Assessment of quality of life. In addition, all patients will be asked to fill-in quality of life (QoL) questionnaires - before and 1 month after ablation. Two types of questionnaire will be used: the EuroQoL (EQ-5D) and the EHRA questionnaire which was developed for patients with atrial fibrillation, however, in this study it will used for patients with VA.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
COHORT
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
VA group
Consecutive patients with VA originating from the base of the heart undergoing unipolar ablation
Ablation
Unipolar and bipolar ablation
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Ablation
Unipolar and bipolar ablation
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Initial unipolar ablation of VA originating from the base of the heart (R in II, III and aVF) performed according to the standard scheme which includes detailed measurements of EP parameters at each examined and/or ablated site and inspection of all three regions (RVOT with PA, GCV and LVOT/AoCusps/AMC/MA) in cases with unsatisfactory EP parameters or failed ablation at first or second site.
3. Typical indications for ablation: a. \> 10 000 PVC in 24-hour Holter ECG or b. \> 10% PVC in 24-hour Holter ECG or c. less frequent but symptomatic PVC or d. at least 3 episodes symptomatic non-sustained ventricular tachycardia (nsVT) (\>3 QRS evolutions) in Holter ECG, regardless of the amount of PVC or e. sustained ventricular tachycardia (sVT), regardless of nsVT or PVC
4. Written informed consent
Exclusion Criteria
2. Lack of properly acquired EP parameters during baseline unipolar ablation
3. Lack of baseline Holter ECG performed \< 6 months prior to initial unipolar ablation
4. Absence of typical indication for ablation
5. Lack of written informed consent for participation in the study
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Centre of Postgraduate Medical Education
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Prof. Piotr Kulakowski
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Piotr Kulakowski, MD PhD
Role: PRINCIPAL_INVESTIGATOR
Centre for Medical Postgraduate Education
Agnieszka Sikorska, MD PhD
Role: STUDY_CHAIR
Centre for Medical Postgraduate Education
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Department of Cardiology, Postgraduate Medical School, Grochowski Hospital
Warsaw, , Poland
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Stec S, Sikorska A, Zaborska B, Krynski T, Szymot J, Kulakowski P. Benign symptomatic premature ventricular complexes: short- and long-term efficacy of antiarrhythmic drugs and radiofrequency ablation. Kardiol Pol. 2012;70(4):351-8.
Yamada T, Yoshida N, Doppalapudi H, Litovsky SH, McElderry HT, Kay GN. Efficacy of an Anatomical Approach in Radiofrequency Catheter Ablation of Idiopathic Ventricular Arrhythmias Originating From the Left Ventricular Outflow Tract. Circ Arrhythm Electrophysiol. 2017 May;10(5):e004959. doi: 10.1161/CIRCEP.116.004959.
Neira V, Santangeli P, Futyma P, Sapp J, Valderrabano M, Garcia F, Enriquez A. Ablation strategies for intramural ventricular arrhythmias. Heart Rhythm. 2020 Jul;17(7):1176-1184. doi: 10.1016/j.hrthm.2020.02.010. Epub 2020 Feb 20.
Koruth JS, Dukkipati S, Miller MA, Neuzil P, d'Avila A, Reddy VY. Bipolar irrigated radiofrequency ablation: a therapeutic option for refractory intramural atrial and ventricular tachycardia circuits. Heart Rhythm. 2012 Dec;9(12):1932-41. doi: 10.1016/j.hrthm.2012.08.001. Epub 2012 Aug 2.
Sauer PJ, Kunkel MJ, Nguyen DT, Davies A, Lane C, Tzou WS. Successful ablation of ventricular tachycardia arising from a midmyocardial septal outflow tract site utilizing a simplified bipolar ablation setup. HeartRhythm Case Rep. 2018 Nov 20;5(2):105-108. doi: 10.1016/j.hrcr.2018.11.002. eCollection 2019 Feb. No abstract available.
Futyma P, Santangeli P, Purerfellner H, Pothineni NV, Gluszczyk R, Ciapala K, Moroka K, Martinek M, Futyma M, Marchlinski FE, Kulakowski P. Anatomic approach with bipolar ablation between the left pulmonic cusp and left ventricular outflow tract for left ventricular summit arrhythmias. Heart Rhythm. 2020 Sep;17(9):1519-1527. doi: 10.1016/j.hrthm.2020.04.029. Epub 2020 Apr 26.
Futyma P, Sander J, Ciapala K, Gluszczyk R, Wysokinska A, Futyma M, Kulakowski P. Bipolar radiofrequency ablation delivered from coronary veins and adjacent endocardium for treatment of refractory left ventricular summit arrhythmias. J Interv Card Electrophysiol. 2020 Sep;58(3):307-313. doi: 10.1007/s10840-019-00609-9. Epub 2019 Aug 11.
Della Bella P, Peretto G, Paglino G, Bisceglia C, Radinovic A, Sala S, Baratto F, Limite LR, Cireddu M, Marzi A, D'Angelo G, Vergara P, Gulletta S, Mazzone P, Frontera A. Bipolar radiofrequency ablation for ventricular tachycardias originating from the interventricular septum: Safety and efficacy in a pilot cohort study. Heart Rhythm. 2020 Dec;17(12):2111-2118. doi: 10.1016/j.hrthm.2020.06.025. Epub 2020 Jun 26.
Igarashi M, Nogami A, Fukamizu S, Sekiguchi Y, Nitta J, Sakamoto N, Sakamoto Y, Kurosaki K, Takahashi Y, Kimata A, Komatsu Y, Machino T, Kuroki K, Yamasaki H, Aonuma K, Ieda M. Acute and long-term results of bipolar radiofrequency catheter ablation of refractory ventricular arrhythmias of deep intramural origin. Heart Rhythm. 2020 Sep;17(9):1500-1507. doi: 10.1016/j.hrthm.2020.04.028. Epub 2020 Apr 28.
Kany S, Alken FA, Schleberger R, Baran J, Luik A, Haas A, Ene E, Deneke T, Dinshaw L, Rillig A, Metzner A, Reissmann B, Makimoto H, Reents T, Popa MA, Deisenhofer I, Piotrowski R, Kulakowski P, Kirchhof P, Scherschel K, Meyer C. Bipolar ablation of therapy-refractory ventricular arrhythmias: application of a dedicated approach. Europace. 2022 Jul 15;24(6):959-969. doi: 10.1093/europace/euab304.
Cronin EM, Bogun FM, Maury P, Peichl P, Chen M, Namboodiri N, Aguinaga L, Leite LR, Al-Khatib SM, Anter E, Berruezo A, Callans DJ, Chung MK, Cuculich P, d'Avila A, Deal BJ, Della Bella P, Deneke T, Dickfeld TM, Hadid C, Haqqani HM, Kay GN, Latchamsetty R, Marchlinski F, Miller JM, Nogami A, Patel AR, Pathak RK, Saenz Morales LC, Santangeli P, Sapp JL Jr, Sarkozy A, Soejima K, Stevenson WG, Tedrow UB, Tzou WS, Varma N, Zeppenfeld K. 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias: Executive summary. J Interv Card Electrophysiol. 2020 Oct;59(1):81-133. doi: 10.1007/s10840-019-00664-2.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
123/2022
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.