Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
50 participants
INTERVENTIONAL
2011-10-31
2012-10-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Methods and results Handgrip strength and VO2 max determined strength and endurance. Twenty-three medicine (M) and 27 physical education (PE) female students performed 30 minutes CPR. Compression quality and ECG were continuously monitored, heartrate and non-invasive blood pressure (NIBP) every 2 minutes. Capillary pH, PcCO2, lactate, potassium and sodium bicarbonate were analyzed every 10 minutes.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Optimal Training Frequency for Attainment and Maintenance of High-quality CPR on a High-fidelity Manikin
NCT02998307
Three Different Cardiopulmonary Resuscitation (CPR) Training Methods
NCT01361919
Assessment of CPR Skills Acquisition and Retention: Impact of Technology and Self-training
NCT05493189
Ultra-Brief Versus Brief Hands Only CPR Video Training With and Without Psychomotor Skill Practice
NCT01191736
Standard CPR Versus Chest Compressions Only
NCT04569812
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
2.2 Study protocol The participants were divided into two groups according to their expected physical condition: Medicine students (M; n=23) and Physical Education students (PE; n=27). As a consequence of their curriculum we expected the physical education students to have a good or at least better physical condition compared to the medical students. The participants' height (anthropometer GPM, DKSH Switzerland), weight (electronic SECA, 815 Elegantia) and body fat percentage (Harpende Skinfold Calliper, Fysio Supplies) were measured. Body mass index (BMI; kg/m²) was calculated. To assess baseline strength and endurance respectively, we measured hand grip strength (kg) (Hydraulic hand dynamometer, Sachon corporation, Mason) as a determinant of general muscle strength and we estimated maximal oxygen uptake (ml/kg/min) by means of an endurance shuttle run test as a parameter of maximal aerobic power.In order to detect unknown cardiac abnormalities a 12 lead ECG (Delta 60 plus, Cardioline) was performed in all volunteers.
All participants were considered as lay rescuers and had received previous CPR training. However, to avoid any pre-testing difference, each group received a CPR instruction booster, using the ERC-accredited 4-stage approach, one week before the study.
After this, the students were asked to perform a 30 minutes sustained CPR sequence (30:2). Regarding the available evidence on the impact of CPR feedback devices on CPR quality, participants were given real-time feedback on hand positioning, compression depth, ventilation volume and a metronome continuously provided a rhythm of 100-120 compressions per minute.(5) CPR quality data were registered using a Laerdal Resusci Anne manikin (Laerdal, Norway) connected to a Laerdal PC Skill reporting software (version 2.4) and simultaneously monitored by an observer.
To define compressions as adequate, they were automatically evaluated for depth (\>5 cm), frequency (100-120/min) and complete release (\<0.5 cm). The ventilations were automatically evaluated for the inflated volume (400-1000 ml). The 30:2 CPR was performed during 30 minutes with a hands-off period every 2 minutes during the AED analysis. This time interval was used to measure and register the volunteers heart rate (bpm), non-invasive blood pressure (NIBP) and peripheral oxygen saturation (SpO2), which was repeated every 2 minutes. All participants were connected to a continuous 5 lead ECG monitor (SC 9000 xl, Siemens). In addition to the non invasive monitoring, capillary blood samples from the fingertip were taken every 10 minutes to analyze the pH, PcCO2, lactate, potassium and sodium bicarbonate (Radiometer ABL90 Flex, Denmark). The results of the non-invasive and capillary monitoring were evaluated by an anaesthesiologist and exercise physiologist throughout the whole exercise. In case of hypertension or arrhythmia, tiredness, feeling unwell or failure to maintain correct compression rhythm or depth the participant was asked to stop the physical effort and the reason was noted. At the end of the 30 minutes the participants were asked to appraise their feeling of exertion on a "Borg rating of perceived exertion scale" ranging from 6 to 20.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
BASIC_SCIENCE
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Medicine students
students with normal expected fitness
Physiological responses during sustained CPR
Physical education students
students with better expected fitness
Physiological responses during sustained CPR
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Physiological responses during sustained CPR
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
FEMALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University Ghent
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
B670201112158
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.