A Controlled Study of Improved Javelin Side Recumbent Position and Conventional Postural Placement

NCT ID: NCT05551442

Last Updated: 2022-09-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

60 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-12-12

Study Completion Date

2022-09-07

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The Da Vinci surgical robot Xi system assisted laparoscopic pyeloureteroplasty uses the improved javelin side lying position, which can alleviate the unsafe factors of falling from the bed caused by the conventional posture, shorten the time of placing the posture5, prevent the possible pressure injuries and intraoperative complications caused by the conventional posture surgery, and the operation is more simple and convenient. The mechanical arm of the Da Vinci robot will not have the potential risk factors of crushing the head, face and trunk of the patient during the entire operation process, It is safe and reliable, making the whole process of positioning convenient and time-saving. It can not only improve the connection efficiency of each operation, but also ease the work intensity of nurses and reduce the incidence of robot secondary berths. Operator satisfaction. It is safe and reliable to achieve good results, improve the operation safety, effectively avoid intraoperative and postoperative complications, and ensure the operation safety of patients, which is worth promoting.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

To discuss the comparative study of different localization methods in robot-assisted laparoscopic epirenoplasty.

From December 2021 to January 2022, the researchers selected 60 participants to undergo laparoscopic pyroplasty assisted by the Da Vinci Robotic Xi system. Depending on the order of the surgeries, the researchers randomly assigned them, the subjects into three groups: control group A, control group B and observation group C, each with 20 cases. In control group A, we adopted the conventional lateral position, control group B adopted the lumbar bridge cushion lateral position, and observation group C adopted the modified javelin lateral position, The operation time, secondary berth incidence, operation time, intraoperative blood loss and the incidence of intraoperative complications were compared among the three groups.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Nurse-Patient Relations

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

In control group A,

In control group A, we adopted the conventional lateral position

To explore the comparative study of different positioning methods in robot assisted laparoscopic pyeloplasty.

Intervention Type PROCEDURE

The incidence of surgical positioning time and secondary berths, surgical time, intraoperative blood loss and intraoperative complications were compared among the three groups.

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

Intervention Type DEVICE

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

control group B

control group B adopted the lumbar bridge cushion lateral position

To explore the comparative study of different positioning methods in robot assisted laparoscopic pyeloplasty.

Intervention Type PROCEDURE

The incidence of surgical positioning time and secondary berths, surgical time, intraoperative blood loss and intraoperative complications were compared among the three groups.

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

Intervention Type DEVICE

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

observation group C

observation group C adopted the modified javelin lateral position

To explore the comparative study of different positioning methods in robot assisted laparoscopic pyeloplasty.

Intervention Type PROCEDURE

The incidence of surgical positioning time and secondary berths, surgical time, intraoperative blood loss and intraoperative complications were compared among the three groups.

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

Intervention Type DEVICE

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

To explore the comparative study of different positioning methods in robot assisted laparoscopic pyeloplasty.

The incidence of surgical positioning time and secondary berths, surgical time, intraoperative blood loss and intraoperative complications were compared among the three groups.

Intervention Type PROCEDURE

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

To discuss the comparative study of different position placement methods of renal pelvis ureteroplasty on the Da Vinci robotic Xi platform

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Exclusion Criteria

1. Patients who can use balloon dilation to achieve the therapeutic purpose
2. Open surgery is required
Minimum Eligible Age

2 Months

Maximum Eligible Age

5 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Guiyang Maternal and Child Health Care Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Jing P Liu, doctorat

Role: STUDY_DIRECTOR

Guizhou Provincial People's Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

GuiyangMaternalChildHCH

Guiyang, , China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Xu Pu

Identifier Type: -

Identifier Source: org_study_id

More Related Trials