Research of Spiral Exhalation Device Oxygen Therapy to Improve the Treatment Effect of Patients With Severe Pneumonia
NCT ID: NCT05452759
Last Updated: 2022-07-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
156 participants
INTERVENTIONAL
2022-08-01
2025-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
In the previous study, we improved the "New Artificial Airway High Flow Humidification Oxygen Therapy Device" (NTHF) to improve the accuracy of gas flow rate, and unified the baseline with AIRVOTM2. The status quo of the obvious differences in the airway humidification effect of patients. The pre-experiment again found that the gas flow rate consumption was significantly lower than that of AIRVOTM2 after the NTHF exhalation port was optimized, and the gas flow rate was proportional to the inhaled gas humidity. Based on this, we hypothesized that the flow rate of the optimized expiratory port of NTHF is more stable than that of AIRVOTM2, which can improve the airway humidification effect of patients. We intend to adopt a randomized controlled clinical study design, by comparing the application of two oxygen therapy devices in patients with severe pneumonia artificial airway, to explore whether NTHF can promote the clearance of airway secretions in patients with severe pneumonia and improve the therapeutic effect of severe pneumonia. Oxygen therapy nursing mode in patients with severe pneumonia artificial airway.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Research on a NTHF to Improve Pulmonary Function in Patients With Respiratory Failure
NCT05435079
Non-invasive Mechanical Ventilation as a Rescue Therapy to Relieve Dyspnea in Patients With Stable Severe COPD
NCT02012101
Evaluation of a Lightweight Nasal Interface and Ventilator in Patients With Respiratory Disease
NCT02278107
Study of Neural Inspiratory Time and Expiratory Delay in Patient and Health During Spontaneous Breathing and Ventilation
NCT02817035
Effects of High-intensity Noninvasive Positive Pressure Ventilation in AECOPD
NCT04044625
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Before the start of the study, all enrolled patients were required to sign an informed consent form. Patients who met the inclusion criteria were divided into NTHF exhalation port optimization group (experimental group) and AIRVOTM2 exhalation port conventional group (control group) according to the ratio of 1:1, with 78 cases in each group. The method of block randomization with random block size is adopted, and the random number and grouping result generated by the computer are used to make a random grouping card, which is stored in a sealed and opaque envelope with the same surface. And the envelopes are numbered one-time according to the sequence number of the random grouping method. The researcher selects the corresponding envelope according to the order in which the subjects entered the experiment, obtains the grouping number, and gives the subjects different high-flow humidified oxygen therapy strictly according to the card.
Blind method: This study is a single-blind study. The researcher clearly defines the treatment group, but the index evaluation, data collection and data statistics are completed by different trained researchers, and the treatment group is not clear.
Intervention group: use NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. , adjust the concentration of the venturi valve and the corresponding oxygen flow according to the monitored pulse oxygen saturation (SpO2), and test the pipeline at the preset gas flow rate levels of 40L/min, 50L/min and 60L/min respectively. Connect the actual gas flow rate value and gas flow rate loss difference before and after the optimized expiratory joint (screw joint), and measure the gas temperature and humidity at the near-patient end of the pipeline at the corresponding gas flow rate.
Control group: use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapeutic apparatus to 40L/min and 50L/min respectively. and 60L/min, measure the actual gas flow rate and the gas flow loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and at the corresponding gas flow rate, measure the gas near the patient end of the pipeline. temperature and humidity.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
new type of tracheotomy high-flow oxygen therapy (NTHF)
Using NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. The monitored pulse oxygen saturation (SpO2) is used to adjust the concentration of the venturi valve and the corresponding oxygen flow rate. At the preset gas flow rate levels of 40L/min, 50L/min and 60L/min, the test pipeline is connected to optimize the breath. The actual gas flow rate value and the gas flow rate loss difference before and after the gas joint (screw joint), and at the corresponding gas flow rate, measure the gas temperature and humidity at the near-patient end of the pipeline.
high-flow oxygen therapy device for Severe pneumonia patients with artificial airway
Using NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. The monitored pulse oxygen saturation (SpO2) is used to adjust the concentration of the venturi valve and the corresponding oxygen flow rate. At the preset gas flow rate levels of 40L/min, 50L/min and 60L/min, the test pipeline is connected to optimize the breath. The actual gas flow rate value and the gas flow rate loss difference before and after the gas joint (screw joint), and at the corresponding gas flow rate, measure the gas temperature and humidity at the near-patient end of the pipeline.
Respiratory Humidification Treatment( AIRVO TM 2)
Use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapy device to 40L/min, 50L/min and 60L/min, respectively. min, measure the actual gas flow rate value and the gas flow rate loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and measure the gas temperature and humidity near the patient end of the pipeline at the corresponding gas flow rate.
AIRVOTM2 device for Severe pneumonia patients with artificial airway
Use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapy device to 40L/min, 50L/min and 60L/min, respectively. min, measure the actual gas flow rate value and the gas flow rate loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and measure the gas temperature and humidity near the patient end of the pipeline at the corresponding gas flow rate.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
high-flow oxygen therapy device for Severe pneumonia patients with artificial airway
Using NTHF, adjust the MR850 humidifier to invasive automatic gear, the temperature sensor automatically adjusts and maintains the gas temperature at the entrance of the tracheal tube at 37°C according to the feedback temperature, and monitors and maintains SpO2 between 94% and 100%. The monitored pulse oxygen saturation (SpO2) is used to adjust the concentration of the venturi valve and the corresponding oxygen flow rate. At the preset gas flow rate levels of 40L/min, 50L/min and 60L/min, the test pipeline is connected to optimize the breath. The actual gas flow rate value and the gas flow rate loss difference before and after the gas joint (screw joint), and at the corresponding gas flow rate, measure the gas temperature and humidity at the near-patient end of the pipeline.
AIRVOTM2 device for Severe pneumonia patients with artificial airway
Use AIRVOTM2 (Fisher \& Paykel, Auckland, New Zealand), select the output gas temperature of 37°C, monitor and maintain SpO2 between 94% and 100%, and adjust the output gas flow rate of the therapy device to 40L/min, 50L/min and 60L/min, respectively. min, measure the actual gas flow rate value and the gas flow rate loss difference before and after each flow rate horizontal pipeline is connected to the conventional exhalation joint (matching special exhalation joint), and measure the gas temperature and humidity near the patient end of the pipeline at the corresponding gas flow rate.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* The patient has artificial airway preparation or has been released from the ventilator.
* Needs to receive oxygen therapy for more than 24 hours.
* The expected retention days of the tracheal tube ≥ 7 days ⑤ Sign the informed consent
Exclusion Criteria
* Patients with pregnancy and end-stage tumors ③Airway hemorrhage
* Medical history of airway injury, pulmonary trauma, lung surgery ⑤ Hypothermia (\<35℃), restrictive body fluid deficiency
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Shenzhen Second People's Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
MEI YANGMEI
Role: STUDY_CHAIR
Shenzhen Second People's Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Shenzhen Second People's Hospital
Shenzhen, Guangdong, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
20223357002
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.