Research on a NTHF to Improve Pulmonary Function in Patients With Respiratory Failure
NCT ID: NCT05435079
Last Updated: 2022-06-28
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
138 participants
INTERVENTIONAL
2022-07-01
2024-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The project team is committed to the innovation of high-flow oxygen therapy devices and the research on oxygen therapy care. In the early stage, the "New Artificial Airway High Flow Oxygen Therapy Device" was designed (NTHF), in 2018, the new technology and new projects were declared and approved to solve the problem of the flow rate of oxygen therapy devices. In the pre-test, 78 tracheotomy patients were observed using NTHF and respiratory humidification therapy device (AIRVOTM2 ) with high-flow oxygen therapy. As a result, NTHF was superior to AIRVOTM2 in improving airway humidification, oxygenation effect and cost, and published an article, which was approved in 2019 "Non-inferiority of humidification performance of a novel high-flow oxygen therapy device in oxygen therapy for tracheostomy-off-weaned patients. In 2021, it will be approved for the promotion of appropriate technologies for health and health in Guangdong Province. Relying on the high-level clinical key specialties of Guangdong Province, support with scientific research technology and financial support conditions.
Research hypothesis: NTHF has the physiological effects of increasing the positive expiratory pressure of artificial airway, alveolar ventilation, and humidification, and can improve the lung function of patients with respiratory failure after tracheotomy.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Research of Spiral Exhalation Device Oxygen Therapy to Improve the Treatment Effect of Patients With Severe Pneumonia
NCT05452759
The Effects of Different Non-invasive Respiratory Support
NCT07247318
High Flow Nasal Oxygen Therapy in Perioperative Period of the Adult With Hypercapnic and Hypoxemic Respiratory Faliure
NCT03229460
High Flow Nasal Cannulae Oxygen Therapy in Respiratory Insufficiency Patients
NCT02972021
High-Flow-Therapy for the Treatment of Cheyne-Stokes-Respiration in Chronic Heart Failure
NCT03102827
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
1.2 The project team is committed to the innovation of high-flow oxygen therapy devices and research on oxygen therapy care. In the early stage, the "New Artificial Airway High Flow Oxygen Therapy Device" was designed (NTHF), in 2018, the new technology and new projects were declared and approved to solve the flow rate problem of oxygen therapy devices ,observing 78 tracheotomized patients using NTHF and respiratory humidification therapy device (AIRVOTM2) Perform high-flow oxygen therapy. As a result, NTHF was superior to AIRVOTM2 in improving airway humidification, oxygenation, and cost, and published an article. Approved in 2019 "New high-flow oxygen therapy device in tracheotomy Non-inferiority study of humidification performance in oxygen therapy for weaned patients" (funded 150,000 yuan, China Clinical Research Registry, ChiCTR1900023421). 2021 , it was approved to promote the "Artificial Airway High Flow Oxygen Therapy Airtight Suction Technology" in Guangdong Province for Health and Health Appropriate Technology . Relying on Guangdong Province High-level clinical key specialties,support with scientific research technology and financial support condition.
1.3 Scientific assumption: NTHF has the physiological effects of increasing positive expiratory pressure of artificial airway, alveolar ventilation, and humidification, and can improve respiratory failure trachea,The patient's lung function was incised.
2 goals 2.1 To evaluate the effect of NTHF on improving pulmonary ventilation, ventilation and defense function in patients with respiratory failure artificial airway.
2.2 Obtain evidence that NTHF improves pulmonary function in patients with respiratory failure, and establish a new model of oxygen therapy nursing for patients with artificial airway in respiratory failure.
3 Research content 3.1 In a randomized parallel control method, NTHF and AIRVOTM2 were used in two groups of patients with respiratory failure artificial airway, and the two groups of patients were observed for 7 days.
The oxygenation index, respiratory rate, and mechanical ventilation time were analyzed, and the improvement of oxygenation in patients with respiratory failure by two oxygen therapy devices was analyzed.
3.2 Comparing the results of pulmonary function tests and microbial metagenomic testing of the two groups of patients before treatment and after 7 days of treatment, to explore the effect of NTHF on improving pulmonary function and patient comfort in patients with mild and moderate respiratory failure, and to explore the effect of NTHF in patients with respiratory failure caused by different diseases. A new model of oxygen therapy care.
4 Key issues to be addressed 4.1 To verify the effect of the new high-flow oxygen therapy device in improving oxygenation, ventilation and humidification of patients with respiratory failure artificial airway.
4.2 To explore whether the new high-flow oxygen therapy device can improve the lung function of patients with respiratory failure artificial airway, and establish a new model of oxygen therapy nursing.
5 Expected results 5.1 Academic indicators: Establish a personalized weaning scheme for patients with respiratory failure and a new nursing model for tracheotomy and high-flow humidified oxygen therapy. Published papers 1-2Participate in academic exchange conferences.
5.2 Talent training: train 1-2 respiratory therapists and graduate students. 5.3 Social and economic benefits: reduce the time of mechanical ventilation in patients with respiratory failure,Shorten the days of hospitalization, reduce costs, and reduce the burden on families and society.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SUPPORTIVE_CARE
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
new type of tracheotomy high-flow oxygen therapy (NTHF)
NTHF (connect the oxygen suction tube, Venturi, Fisher \& Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, airtight suction tube and tracheotomy in sequence from the output end of the automatic pressure-adjustable oxygen flow meter Catheter), adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy catheter at 37°C according to the feedback temperature, and adjusts according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate of the oxygen therapy device is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.
high-flow oxygen therapy device for tracheotomized patients
From the output end of the automatic pressure-adjustable oxygen flow meter, connect the oxygen suction tube, Venturi, Fisher \& Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, closed sputum suction tube and tracheostomy tube), Adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy tube at 37°C according to the feedback temperature, and adjusts the oxygen therapy device according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.
Respiratory Humidification Treatment( AIRVO TM 2)
AIRVOTM 2 (Fisher \& Paykel, Auckland, New Zealand), connect the special breathing circuit, tracheostomy joint and tracheostomy tube in sequence from the output end of the oxygen flow meter. The gas outflow from the mouth is the standard, adjust the output gas flow rate of the therapy device to 40-60L/min, adjust the oxygen concentration according to the monitored pulse oxygen saturation (SpO 2 ), and maintain the SpO 2 between 94% and 100%. .
high-flow oxygen therapy device for tracheotomized patients
From the output end of the automatic pressure-adjustable oxygen flow meter, connect the oxygen suction tube, Venturi, Fisher \& Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, closed sputum suction tube and tracheostomy tube), Adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy tube at 37°C according to the feedback temperature, and adjusts the oxygen therapy device according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
high-flow oxygen therapy device for tracheotomized patients
From the output end of the automatic pressure-adjustable oxygen flow meter, connect the oxygen suction tube, Venturi, Fisher \& Paykel MR850 heated humidifier, RT308 breathing tube with humidification tank, closed sputum suction tube and tracheostomy tube), Adjust the MR850 to invasive automatic transmission, the temperature sensor automatically adjusts and maintains the gas temperature at the inlet of the tracheostomy tube at 37°C according to the feedback temperature, and adjusts the oxygen therapy device according to the gas outflow from the exhalation port of the patient's inspiratory phase. The gas flow rate is 40-60L/min. According to the monitored pulse oxygen saturation (SpO 2 ), the concentration of the venturi valve and the corresponding oxygen flow rate are adjusted to maintain the SpO 2 between 94% and 100%.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Have an artificial airway, ready or have been released from the ventilator
3. The circulation is basically stable, and there are no shocks of various types that are difficult to correct (mean arterial pressure remains unchanged under the condition of vasoactive drugs).
\<65mmHg)
4. Consciousness and ability to cooperate with clinical treatment
Exclusion Criteria
2. History of airway injury, pulmonary trauma, and lung surgery
3. Central respiratory failure or status asthmaticus caused by neurological diseases
4. Refusing to cooperate with treatment or to participate in the researcher
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Shenzhen Second People's Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
MEI YANGMEI
Role: STUDY_CHAIR
Shenzhen Second People's Hospital
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Shenzhen Second People's Hospital
Shenzhen, Guangdong, China
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
A2022088
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.