Neural Integrity Monitor Electromyogram (NIM-EMG) Endotracheal Tube Intubation With Video Laryngoscope
NCT ID: NCT05366582
Last Updated: 2023-03-14
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
60 participants
INTERVENTIONAL
2022-05-10
2022-11-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
C-MAC D-Blade vs Macintosh for Postoperative Vocal Cord Evaluation
NCT07277985
Influenced the Type of Laryngoscopy the Intraoperative Nerve Monitoring During Thyroid Surgery
NCT02943980
The Effect of McGrath Video Laryngoscope on the Glottic View at Thyroid Surgery Position
NCT05251194
Comparison of Video Laryngoscopy and Conventional Laryngoscopy for Safe Intubation in Adult Thyroid Surgery Patients With Anticipated Difficult Airway
NCT07113171
Univent Tube for Thoracoscopic Thymectomy in Myasthenic Patients
NCT06101407
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The placement of the tube may change due to reasons such as movement of the neck during the operation. In addition, endotracheal tube placement may be problematic due to poor vision during direct laryngoscopy. Incorrect placement of the tube may result in equipment inoperability and increase the likelihood of injury to the recurrent laryngeal nerve.
Laryngoscopy is a term for tracheal intubation that provides visualization and evaluation of the larynx with its upper airway structures.
Until recently, direct laryngoscopy was considered the standard technique for endotracheal intubation. Recently, a wide variety of methods have been developed for endotracheal intubation. Video laryngoscopes are similar to direct laryngoscopes but provide laryngeal imaging with a small video chip on their blade. This imaging is superior compared to direct laryngoscopy. The aim of the study was to compare the use of direct laryngoscopy and video laryngoscopy in intubation with the NIM-EMG tube, which is routinely used in operations where the recurrent laryngeal nerve (RLN) may be damaged, in terms of intubation success, intubation time, tracheal intubation comfort, hemodynamic responses, surgical satisfaction, and complications that may develop after anesthesia or surgery.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SCREENING
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group Macintosh Laryngoscope (ML)
Macintosh laryngoscope is used for intubation after anesthesia induction
Macintosh Laryngoscope
After the induction, laryngoscopy will be performed with a Macintosh laryngoscope after 2 minutes of manual ventilation after muscle relaxant by an anesthesiologist with at least 4 years of experience. Patients will be intubated with the "Medtronic Xomed Nerve Integrity Monitor Standard Reinforced ElectromyographyEndotracheal Tube" (size 6.0, 7.0 or 8.0). The cuff of the intubation tube will be connected to a manometer and inflated at a pressure of 20-30 mmHg until there is no air leak. Intubation will be confirmed by the appearance of end-tidal carbon dioxide (CO2). Failed intubation will be considered if not achieved within 2 minutes
Group Video Laryngoscope (VL)
Video laryngoscope is used for intubation after anesthesia induction
Video Laryngoscope
After the induction, laryngoscopy will be performed with a Video laryngoscope after 2 minutes of manual ventilation after muscle relaxant by an anesthesiologist with at least 4 years of experience. Patients will be intubated with the "Medtronic Xomed Nerve Integrity Monitor Standard Reinforced ElectromyographyEndotracheal Tube" (size 6.0, 7.0 or 8.0). The cuff of the intubation tube will be connected to a manometer and inflated at a pressure of 20-30 mmHg until there is no air leak. Intubation will be confirmed by the appearance of end-tidal CO2. Failed intubation will be considered if not achieved within 2 minutes
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Macintosh Laryngoscope
After the induction, laryngoscopy will be performed with a Macintosh laryngoscope after 2 minutes of manual ventilation after muscle relaxant by an anesthesiologist with at least 4 years of experience. Patients will be intubated with the "Medtronic Xomed Nerve Integrity Monitor Standard Reinforced ElectromyographyEndotracheal Tube" (size 6.0, 7.0 or 8.0). The cuff of the intubation tube will be connected to a manometer and inflated at a pressure of 20-30 mmHg until there is no air leak. Intubation will be confirmed by the appearance of end-tidal carbon dioxide (CO2). Failed intubation will be considered if not achieved within 2 minutes
Video Laryngoscope
After the induction, laryngoscopy will be performed with a Video laryngoscope after 2 minutes of manual ventilation after muscle relaxant by an anesthesiologist with at least 4 years of experience. Patients will be intubated with the "Medtronic Xomed Nerve Integrity Monitor Standard Reinforced ElectromyographyEndotracheal Tube" (size 6.0, 7.0 or 8.0). The cuff of the intubation tube will be connected to a manometer and inflated at a pressure of 20-30 mmHg until there is no air leak. Intubation will be confirmed by the appearance of end-tidal CO2. Failed intubation will be considered if not achieved within 2 minutes
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Age 18-65
* Undergoing Elective Thyroid and Parathyroidectomy surgery
* undergoing Intraoperative Recurrent Laryngeal Nerve Monitoring
Exclusion Criteria
* Body mass index less than 19 or greater than 30
* Muscle relaxant allergy
* Lidocaine allergy
* IDS score \>5
* Uncontrolled hypertension, bronchial asthma, tracheal pathology
* undergoing emergency surgery
* Cases that cannot give informed consent
18 Years
65 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Bezmialem Vakif University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
İsmail SÜMER
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ismail Sumer, MD
Role: PRINCIPAL_INVESTIGATOR
Bezmialem Vakif University
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Bezmialem Vakif University
Istanbul, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Ismail02
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.