"Mini Fluid Challenge Assessment: a Comparison Among Three Hemodynamic Tools"

NCT ID: NCT04934943

Last Updated: 2025-06-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

45 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-08-01

Study Completion Date

2025-08-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The mini fluid challenge (mini\_FC) is a functional hemodynamic test which has been used in different clinical contexts to assess fluid responsiveness.

This test is performed by rapidly injecting a small aliquot of fluid (100 ml over 1 minute), which is followed by the infusion of the residual aliquot of fluid.

Since the threshold of the mini\_FC identified by the literature is rather small (5% of stroke volume (SV) increase after the 100 ml bolus to discriminate between responder and non-responder), it is crucial that the hemodynamic tool assessing this change could be reliable. Moreover, the SV changes with inspiratory/expiratory movements and the increase after the mini\_FC should also consider the physiological fluctuations of the SV.

In the literature this test has been performed by means of tolls with different least significant change of the SV. The least significant change (LSC) represents the smallest difference between successive measurements of SV that can be considered to be a real change and not attributable to chance.

The purpose of this study is to assess the agreement among MOSTCARE system (4.5\& of SV LSC described in the literature) and the echocardiography (about 10% of SV LSC described in the literature) with the PICCO system (about 1% of SV LSC described in the literature - considered the gold standard) in discriminating fluid responsiveness after a mini\_FC

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Targeted fluid therapy has received increasing attention in the management of patients showing acute circulatory failure in both intensive care unit (ICU) and operating room (OR), aiming at preventing both inadequate tissue blood flow and fluid overload. In fact, unnecessary fluid administration can increase morbidity and mortality and length of hospital stay of critically ill and surgical patients.

Since the only physiological reason to give a fluid challenge (FC) is to increase the stroke volume (SV) and this effect is obtained only in about 50% of ICU and OR patients, a vast literature investigated the possibility of predict this effect before FC administration, but the issue remains extremely challenging. Bedside clinical signs and pressure and static volumetric static variables, do not predict fluid responsiveness. Moreover, several physiological factors affect the reliability of the ventilator-induced dynamic changes in pulse pressure and stroke volume \[pulse pressure variation (PPV) and stroke volume (SV) variation (SVV), respectively\], and their echographic surrogates, in a significant number of ICU and OR patients.

To overcome these limitations, the functional hemodynamic assessment (i.e. the assessment of the dynamic interactions of hemodynamic variables in response to a defined perturbation), of fluid responsiveness has gained in popularity. A functional hemodynamic test (FHT) consist in a manoeuvre determining a sudden change in cardiac function and/or heart lung interaction, affecting the hemodynamics of fluid responders and non-responders to a different extent.

The FHT called passive leg raising (PLR) has been successfully used for assessing the fluid responsiveness in ICU patients since 2009 and its reliability has been confirmed by three large meta-analyses. However, the PLR is not usually practicable in the OR.

A lot of different FHTs have been proposed, as alternative to the PLR, in ICU and, more recently, OR. These tests could be basically subdivided in two groups. A subgroup of FHTs is based on sudden and brief variations of the mechanical ventilation to induce a change in right ventricle preload and/or after load and, as consequence, of left ventricle. Among these tests, the rapid administration of a small aliquot of the predefined FC (the so-called mini FC) has gained in popularity in the last years.

On of the drawbacks of this test is that the optimal threshold identified in the literature to stratify responders and non-responders (5% of SV variation) is quite small, and potentially affected by the reliability of the hemodynamic tool used. The aim of this paper is to compare the reliability of a hemodynamic invasive tool (the (PiCCO2 TM, Pulsion Medical Systems, Munich, Germany - considered the gold standard) with a mini-invasive tool (MostCareTM system (Vytech Health, Padua, Italy) and a non-invasive (echocardiography) in predicting the response to the mini-FC in critically ill patients.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Sepsis Shock, Septic Critically Ill

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Intervention _mini_FC

The fluid challenge consists of 4 ml\*Kg of Crystalloids' solution infused over 10 minutes, administered via either a central or a peripheral line.

1. The patient is already connected to the PICCO monitoring for clinical purpose of hemodynamic monitoring (before study enrollment)
2. The MOSTCARE system is connected to the MONITOR of the patient (and not to the patient itself) by means of a cable inserted into the connections system.
3. The echocardiography will be performed by a senior intensivist/cardiologist. The stroke volume is calculated by measuring VTI and diameter at the same point. This is best performed by measuring the diameter of the LVOT in the parasternal long axis (PLAX) view

mini_FC

Intervention Type DIAGNOSTIC_TEST

100 ml of Crystalloids infused over 1 minute - data recording and new baseline - FC 4 ml/kg in 10 minutes - data recording

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

mini_FC

100 ml of Crystalloids infused over 1 minute - data recording and new baseline - FC 4 ml/kg in 10 minutes - data recording

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1\) Acute circulatory failure defined as:

* SAP ≤ 90 mmHg (or a decrease \> 50 mm Hg in hypertensive patients)
* or a mean arterial pressure (MAP) ≤ 70 mmHg
* or the use of vasopressors to maintain SAP \>90 mmHg,
* associated with skin mottling; tachycardia ≥100 beats/min; urinary flow ≤0.5 mL/kg for at least 2 hours; blood lactate level ≥4 mmol/L.

Exclusion Criteria

* known severe myocardial or valvular dysfunction
* cardiac arrhythmias
* severe acute respiratory distress syndrome
* on-going haemodialysis or continuous hemofiltration
* moribund patients
* persistent low quality of the arterial signal affecting hemodynamic monitoring measurements
* poor echographic windows.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Humanitas Clinical and Research Center

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Humanitas Research Hospital

Rozzano, MILANO, Italy

Site Status

Antonio Messina

Novara, Novara, Italy

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Italy

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Antonio Messina, MD

Role: primary

+390282241

Antonio Messina, MD

Role: backup

+3902822414131

References

Explore related publications, articles, or registry entries linked to this study.

Messina A, Lionetti G, Foti L, Bellotti E, Marcomini N, Cammarota G, Bennett V, Saderi L, Sotgiu G, Della Corte F, Protti A, Monge Garcia MI, Romagnoli S, Cecconi M. Mini fluid chAllenge aNd End-expiratory occlusion test to assess flUid responsiVEness in the opeRating room (MANEUVER study): A multicentre cohort study. Eur J Anaesthesiol. 2021 Apr 1;38(4):422-431. doi: 10.1097/EJA.0000000000001406.

Reference Type BACKGROUND
PMID: 33399372 (View on PubMed)

de Courson H, Ferrer L, Cane G, Verchere E, Sesay M, Nouette-Gaulain K, Biais M. Evaluation of least significant changes of pulse contour analysis-derived parameters. Ann Intensive Care. 2019 Oct 11;9(1):116. doi: 10.1186/s13613-019-0590-z.

Reference Type BACKGROUND
PMID: 31602550 (View on PubMed)

Georges D, de Courson H, Lanchon R, Sesay M, Nouette-Gaulain K, Biais M. End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study. Crit Care. 2018 Feb 8;22(1):32. doi: 10.1186/s13054-017-1938-0.

Reference Type BACKGROUND
PMID: 29415773 (View on PubMed)

Messina A, Dell'Anna A, Baggiani M, Torrini F, Maresca GM, Bennett V, Saderi L, Sotgiu G, Antonelli M, Cecconi M. Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness. Crit Care. 2019 Jul 29;23(1):264. doi: 10.1186/s13054-019-2545-z.

Reference Type BACKGROUND
PMID: 31358025 (View on PubMed)

Shi R, Monnet X, Teboul JL. Parameters of fluid responsiveness. Curr Opin Crit Care. 2020 Jun;26(3):319-326. doi: 10.1097/MCC.0000000000000723.

Reference Type BACKGROUND
PMID: 32332283 (View on PubMed)

Vistisen ST, Scheeren TWL. Challenge of the Mini-fluid Challenge: Filling Twice without Creating a Self-fulfilling Prophecy Design. Anesthesiology. 2018 May;128(5):1043-1044. doi: 10.1097/ALN.0000000000002141. No abstract available.

Reference Type BACKGROUND
PMID: 29664782 (View on PubMed)

Biais M, de Courson H, Lanchon R, Pereira B, Bardonneau G, Griton M, Sesay M, Nouette-Gaulain K. Mini-fluid Challenge of 100 ml of Crystalloid Predicts Fluid Responsiveness in the Operating Room. Anesthesiology. 2017 Sep;127(3):450-456. doi: 10.1097/ALN.0000000000001753.

Reference Type BACKGROUND
PMID: 28640019 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

MINI3

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.