Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
ACTIVE_NOT_RECRUITING
NA
32 participants
INTERVENTIONAL
2021-07-23
2025-09-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This study will prospectively compare visual satisfaction and ease of use between corneal gas permeable and scleral lenses for patients with mild to moderate keratoconus.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Risk Factors and Progression of Keratoconus
NCT05676580
Corneal Changes After Crosslinking in Keratoconus Patients Compared to the Untreated Fellow Eye
NCT02428166
Wavefront Guided Scleral Lenses for Keratoconus and Irregular Astigmatism
NCT04698590
Effect of Corneal and Scleral RGP Lenses on Ocular Health and Visual Quality in Keratoconus
NCT06921967
Validation of Innovative Scheimpflug Topography Derived RGP Contact Lens Designs In Optometry Network
NCT06312163
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The investigators hypothesize that study participants will select scleral lens over corneal gas permeable lens as their preferred final lens type of choice.
The Primary outcome measure of this study is participant selected final lens choice for continued use for the management of keratoconus.
Methods:
Study Design This is a prospective, multi-center, randomized interventional clinical trial with a 2x2 crossover design of patients with keratoconus fit with corneal and scleral gas permeable contact lenses. The crossover design allows intra-subject differences between two randomized groups with participants serving as their own controls. Contact lens #1 will be the SynergEyes VS (Synergeyes, Inc., Carlsbad CA) which features bi-tangential toric peripheries with linear landing zones. The standard lens is 16.0mm and is available from 14.5 to 17.5mm diameters. Contact lens #2 will be the RoseK2 corneal gas permeable lens (Blanchard Contact Lens, Inc. Manchester, NH). The lens is available in with a base curve range from 4.30 to 8.60 mm, diameter of 7.90 to 10.40mm.
Inclusion Criteria
* Age 18 or older.
* Diagnosis of keratoconus.
* Available baseline corneal topography and pachymetry
* Amsler-Krumeich keratoconus classification of stage 1 or higher
Exclusion Criteria
* No prior corneal transplantation or INTACTS
* No prior use of hybrid, corneal or scleral gas permeable lenses
* Presence of corneal scarring
Study procedures During the initial study visits patient demographics, past ocular and medical history and best corrected visual acuity with manifest refraction will be recorded. Additional testing may include corneal topography, pachymetry and meibography. Dry eye symptoms and contact lens comfort will be assessed using the OSDI and CLDEQ questionnaires.
Participants will be fit according to standard practices with the RoseK 2 corneal gas permeable and Synergeyes VS scleral lenses following manufacturer's recommendations. Over refraction and best corrected visual acuity will be recorded. Subjective comfort with lens use rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
Participants will be randomized to dispense lens #1 vs lens #2. They will be trained in safe application and removal and provided instructions on lens disinfection procedures. Best corrected visual acuity with lens #1 and subjective comfort with lens use will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
At the next visit, participants will return wearing lens #1 for minimum of 3 hours. Best corrected visual acuity with lens #1 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
At the final visit, participants will return wearing lens #2 for minimum of 3 hours. Best corrected visual acuity with lens #2 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
The participant will make a final selection of lens of choice #1 or #2.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Corneal gas permeable lens first
Device: corneal gas permeable contact lenses (RoseK2 corneal Blanchard Contact Lens, Inc. Manchester, NH).
Participants with an odd study ID will be fit with the corneal gas permeable lens first.
Corneal gas permeable lens
Fit in corneal gas permeable contact lens first.
Scleral lens first
Device: scleral lenses (SynergEyes VS (Synergeyes, Inc., Carlsbad CA).
Participants with an even study ID will be fit with the scleral lens first.
Corneal gas permeable lens
Fit in corneal gas permeable contact lens first.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Corneal gas permeable lens
Fit in corneal gas permeable contact lens first.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Available baseline corneal topography and pachymetry
* Amsler-Krumeich keratoconus classification9 of stage 1
Exclusion Criteria
* No prior use of hybrid, corneal or scleral gas permeable lenses
* Presence of corneal scarring.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Illinois at Chicago
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ellen S Shorter
Associate Professor of Clinical Ophthalmology
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Ellen S Shorter, OD
Role: PRINCIPAL_INVESTIGATOR
University of Illinois at Chicago
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Illinois at Chicago Eye and Ear Infirmary
Chicago, Illinois, United States
Illinois Eye Institute
Chicago, Illinois, United States
Mayo Clinic
Rochester, Minnesota, United States
The Ohio State University College of Optometry
Columbus, Ohio, United States
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol
Document Type: Informed Consent Form
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2020-1504
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.