Pilot Study to Evaluate the Revoxa™ System in Hypoxic Patients

NCT ID: NCT04699942

Last Updated: 2024-01-17

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

7 participants

Study Classification

INTERVENTIONAL

Study Start Date

2021-02-01

Study Completion Date

2021-05-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Patients with COVID-19 may suffer from profound hypoxia, requiring the use of supplemental oxygen at high concentrations and flow rates. Non-invasive oxygen delivery systems such as high-flow nasal cannula and non-invasive ventilation have been used in an attempt to avoid the need for intubation and invasive mechanical ventilation. These systems consume large amounts of oxygen, which prevents them from being used in areas without high pressure oxygen sources. In addition, they generate aerosols which have the potential to spread infectious pathogens from the patient's respiratory tract to healthcare workers or other patients in the environment. This study aims to investigate a computer controlled rebreather system which functions to maintain a high fraction of inspired oxygen while minimizing the production of aerosol, among hospitalized patients requiring respiratory support due to hypoxemia. The Revoxa Oxygen Rebreather device can reduce the amount of wasted oxygen and can reduce the potential for any exhaled pathogens entering the surroundings. This type of breathing device is a promising oxygen delivery treatment, but it is not clear if it can offer comparable results to standard treatment. The purpose of this study is to compare the Revoxa Oxygen Rebreather device to standard oxygen delivery methods, including nasal cannula and face mask oxygen, in order to see if similar oxygenation can be achieved at comparable or lower rates of oxygen usage.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This study aims to investigate a two-phase rebreather system (Revoxa Oxygen Rebreather device) among hospitalized patients requiring oxygen therapy. This system can deliver a high fraction of inspired oxygen (FiO2) using a very low flow oxygen source with reduced or no aerosolization. This could provide effective respiratory support with reduced waste and risk of spreading of infectious particles. Such a device could also be used in field hospitals and other makeshift care centers in the event of a surge in demand, because it obviates the need for the type of high-flow oxygen infrastructure that is typically limited to hospital settings.

This is a prospective comparative study of sequential interventions to evaluate the ability of the Revoxa Oxygen Rebreather device (RO) to improve and maintain oxygen saturation at satisfactory levels compared to conventional low-flow supplemental oxygen delivery (COD) via nasal cannula or face mask. Prior to conducting study procedures in the patient population, feasibility of trial procedures will be determined among 3 healthy adults (Group A). The initial procedural test in a healthy sample will not be included in the endpoint assessment. Following initial trial conduct in a healthy sample, 20 adult patients requiring supplemental oxygen will be recruited: adults with non-severe hypoxemia (Group B), followed by enrollment of adults with hypoxemia of any severity not requiring mechanical ventilation (Group C). Baseline measures of oxygen saturation, oxygen flow rate, vital signs (respiratory rate, heart rate, and blood pressure), and patient self-reported dyspnea and comfort will be recorded prior to initiating treatment. Following baseline measurement, either conventional low-flow oxygen delivery or oxygen via the Revoxa Oxygen Rebreather device will be initiated for 20 minutes, followed by the other modality for 20 minutes. To avoid any bias that may be introduced by a fixed sequence of device utilization (eg. COD, then RO), the order in which devices are used will be determined quasi-randomly based on whether the patient is enrolled on an odd numbered day, or an even numbered day. Vital signs, supplemental oxygen, and self-reported dyspnea measures are captured during both treatment regimens. Participants may verbally withdraw at any time by contacting one of the clinical or research staff. At that point, all data collection relating to the withdrawn study participant will be terminated. If the participant wishes, all existing data will be deleted (with the exception of the signed consent form and data related to the consent withdrawal - including the reason for the withdrawal). Additional participants will be recruited to maintain an adequate sample size in the event that participants are withdrawn from the study.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Hypoxemia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

SEQUENTIAL

Following baseline measurement, either conventional low-flow oxygen delivery or oxygen delivery via the Revoxa Oxygen Rebreather device is initiated for 20 minutes, followed by the other modality for 20 minutes. The order of treatments will be determined quasi-randomly based on whether the patient is enrolled on an odd-numbered day, or an even-numbered day.
Primary Study Purpose

SUPPORTIVE_CARE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Conventional

Conventional low-flow Oxygen Delivery

Group Type ACTIVE_COMPARATOR

Conventional (low flow) oxygen delivery via nasal cannula

Intervention Type DEVICE

Conventional (low flow) oxygen delivery via nasal cannula or face mask for 20 minutes

Revoxa

Oxygen Delivery via Revoxa Oxygen Rebreather Device

Group Type EXPERIMENTAL

Revoxa Oxygen Rebrearther

Intervention Type DEVICE

Oxygen delivery via Revoxa Oxygen Rebreather device for 20 minutes

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Conventional (low flow) oxygen delivery via nasal cannula

Conventional (low flow) oxygen delivery via nasal cannula or face mask for 20 minutes

Intervention Type DEVICE

Revoxa Oxygen Rebrearther

Oxygen delivery via Revoxa Oxygen Rebreather device for 20 minutes

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Group A - Healthy adults (≥ 18 years of age) with SpO2 ≥ 96% without oxygen supplementation

Group B - non-severe hypoxemia requiring supplemental oxygen as defined by:

* SpO2 \> 96% with oxygen face mask or nasal cannula with low flow oxygen \<5LPM
* Adults (≥ 18 years of age)

Group C - Hypoxemia requiring supplemental oxygen as defined by:

* Oxygen saturation (SpO2) ≤ 92% on room air as measured by pulse oximetry; or
* SpO2 \< 94% with oxygen face mask or nasal cannula with low flow oxygen \<5LPM
* Adults (≥ 18 years of age)

Exclusion Criteria

* Acute / unstable cardiovascular condition
* Pregnancy
* Imminent need for intubation or noninvasive ventilation
* Glasgow coma scale \<14
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Ironstone Professional Development

UNKNOWN

Sponsor Role collaborator

Dr. David Maslove

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dr. David Maslove

Associate Professor

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Kingston Health Sciences Centre

Kingston, Ontario, Canada

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Canada

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

6031410

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.