Electromyographic and Acceleromyographic Monitoring in Restricted Arm Movement Surgical Setting

NCT ID: NCT04352140

Last Updated: 2023-02-17

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-08-18

Study Completion Date

2022-02-14

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Researchers are comparing the ease of use and repeatability of the force vs electrical activity produced by a muscle after it has undergone nerve stimulation during a surgical procedure in which the patients' arm movement is restricted (placed under surgical drapes) in laparoscopic or robotic procedures.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Residual Neuromuscular Blockade

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Dominant hand

Subject scheduled to undergo an elective surgical procedure will have TetraGraph device lead placement on the dominant hand, ToFscan placed on non-dominant hand

Group Type EXPERIMENTAL

Tetragraph

Intervention Type DEVICE

FDA approved neuromuscular transmission monitor capable of measuring the depth of neuromuscular block in anesthetized patients who received neuromuscular blocking agents. TetraGraph uses EMG to measure the muscle action potentials that are generated in response to electrical neurostimulation via skin electrodes.

ToFscan

Intervention Type DEVICE

ToFscan is a nerve stimulator module used for the measurement of neuromuscular transmission via accelerometry. ToFscan was developed by Drager Technologies, Canada, and it uses a three-dimensional piezoelectric sensor that attaches to the thumb via a hand adapter to measure acceleration in multiple planes (Murphy et al, 2018). Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis will be measured

Non-dominant hand

Subject scheduled to undergo an elective surgical procedure will have TetraGraph device lead placement on the non-dominant hand, ToFscan placed on dominant hand

Group Type EXPERIMENTAL

Tetragraph

Intervention Type DEVICE

FDA approved neuromuscular transmission monitor capable of measuring the depth of neuromuscular block in anesthetized patients who received neuromuscular blocking agents. TetraGraph uses EMG to measure the muscle action potentials that are generated in response to electrical neurostimulation via skin electrodes.

ToFscan

Intervention Type DEVICE

ToFscan is a nerve stimulator module used for the measurement of neuromuscular transmission via accelerometry. ToFscan was developed by Drager Technologies, Canada, and it uses a three-dimensional piezoelectric sensor that attaches to the thumb via a hand adapter to measure acceleration in multiple planes (Murphy et al, 2018). Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis will be measured

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tetragraph

FDA approved neuromuscular transmission monitor capable of measuring the depth of neuromuscular block in anesthetized patients who received neuromuscular blocking agents. TetraGraph uses EMG to measure the muscle action potentials that are generated in response to electrical neurostimulation via skin electrodes.

Intervention Type DEVICE

ToFscan

ToFscan is a nerve stimulator module used for the measurement of neuromuscular transmission via accelerometry. ToFscan was developed by Drager Technologies, Canada, and it uses a three-dimensional piezoelectric sensor that attaches to the thumb via a hand adapter to measure acceleration in multiple planes (Murphy et al, 2018). Following simultaneous ulnar nerve stimulation on each arm, the response of the adductor pollicis will be measured

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age \> or = 18 years old
* Patients willing to participate and provide an informed consent
* Patients undergoing an elective laparoscopic or robotic surgical procedure that requires use of NMBA agents administered intraoperatively.

Exclusion Criteria

* Patients with disorders, such as stroke, carpal tunnel syndrome, broken wrist with nerve damage, Dupuytren contracture, or any similar wrist injury.
* Patients with systemic neuromuscular diseases such as myasthenia gravis
* Patients with significant organ dysfunction that can significantly affect pharmacokinetics of neuromuscular blocking and reversal agents, i.e., severe renal impairment or end-stage liver disease.
* Patients having surgery that would involve prepping the arm or leg into the sterile field
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Mayo Clinic

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

J. Ross Renew, M.D.

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

J.Ross Renew, MD

Role: PRINCIPAL_INVESTIGATOR

Mayo Clinic

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Mayo Clinic in Florida

Jacksonville, Florida, United States

Site Status

Université de Lorraine, CHU de Brabois

Vandœuvre-lès-Nancy, , France

Site Status

University of Debrecen

Debrecen, , Hungary

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States France Hungary

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Related Links

Access external resources that provide additional context or updates about the study.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

20-000629

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Thumb vs Great Toe Recovery
NCT04312256 COMPLETED NA