Electromyographic Monitoring and Postoperative Recovery

NCT ID: NCT03891381

Last Updated: 2021-12-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

TERMINATED

Clinical Phase

NA

Total Enrollment

130 participants

Study Classification

INTERVENTIONAL

Study Start Date

2019-03-26

Study Completion Date

2020-10-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Residual neuromuscular blockade (weakness) is a common occurrence in the postanesthesia care unit when muscle relaxant drugs have been used in the operating room. The only method of reliably detecting residual neuromuscular blockade is through the use of quantitative neuromuscular monitors. These devices measure and quantify the degree of muscle weakness and display the results on a screen. When using train-of-four (TOF) nerve stimulation, the ratio of the fourth muscle contraction (twitch) to the first twitch will be displayed; when this ratio is 90% (or 0.9) or greater, full recovery of muscle strength is present, and the endotracheal tube can be safely removed. At the present time, there is only one commercially available quantitative monitor produced in the United States -the TOF-Watch. The TOF-Watch is not used by many clinicians because it requires experience to obtain accurate results, is expensive, and is subject to interference by factors in the operating room. The aim of this investigation is to examine a new quantitative monitor (the TetraGraph, an electromyography (EMG) device) in the clinical setting. Patients will be randomized to receive either electromyography monitoring (EMG group-using the TetraGraph) or qualitative peripheral nerve stimulator monitoring (PNS group-the standard type of neuromuscular monitoring used at NorthShore University HealthSystem). The primary endpoint of the investigation is the incidence of postoperative residual blockade (defined as a TOF ratio \< 0.9 with TOF-Watch, the current "gold standard quantitative monitor). Secondary endpoints include a variety of standard clinical recovery variables.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Although anesthesiologists recognize that residual neuromuscular block can adversely affect postoperative recovery, a high percentage of patients continue to arrive in the PACU with TOF ratios \< 0.9. An important reason this problem occurs is that anesthesiologists rarely use quantitative neuromuscular monitoring in the operating room. In current anesthesia practices, clinicians typically use standard peripheral nerve stimulators (qualitative neuromuscular monitors) and / or clinical tests of muscle strength to detect residual muscle weakness at the end of surgical procedures. Qualitative nerve stimulators/monitors are routinely used in the operating rooms; TOF electrical stimuli are applied to a peripheral nerve, and the contractions of the innervated muscle observed. However, visual or tactile assessment of TOF stimulation using these monitors is only effective in detecting profound levels of muscle weakness (TOF ratios \< 0.4) Therefore, qualitative nerve stimulators are unable to reliably detect clinically relevant neuromuscular block (TOF ratios of 0.5-0.9). Clinical assessment of patients for signs of muscle weakness (head-lift, hand squeeze) is also an insensitive method of detecting residual neuromuscular block, since many patients can perform these tests with TOF ratios as low as 0.5.

In order for clinicians to reliably exclude residual neuromuscular blockade, quantitative neuromuscular monitoring should be used. At the present time, only one stand-alone quantitative monitor has been produced for clinical use, the TOF-Watch (Blue Star Enterprises, Chanhassen, Minnesota-no longer manufactured). This technology (acceleromyography (AMG)) uses a piezoelectric crystal to sense the acceleration of muscle contractions, and converts this data into a displayed TOF ratio (0-100%). Although the use of the TOF-Watch has been demonstrated to reduce the risk of residual blockade, the routine application of this monitor by clinicians has been limited by a number of factors, related to complexity of use in the operating room.. There is an urgent need for an easy-to-use and accurate quantitative neuromuscular monitor in the clinical setting. Recently, a new device has been developed that uses electromyography (EMG) technology to assess recovery of muscle function in the clinical setting (the TetraGraph). This EMG device measures electrical activity (compound muscle action potentials) following nerve stimulation (usually at the thenar eminence after ulnar or median nerve stimulation). When TOF stimuli are provided, this data is then converted to a measurable TOF ratio (from 0-1.0 or 0-100%). In a study completed at NorthShore University HealthSystem, the investigators compared the applicability (ease of use, equipment need, etc.), repeatability (precision or internal consistency), and performance (agreement with established standard, bias) of this EMG technology to the TOF-Watch (the current clinical "gold standard" quantitative neuromuscular monitor). The subsequent analysis suggested that EMG monitoring accurately measures onset and recovery of neuromuscular function in the operating room.

The use of quantitative neuromuscular monitoring in the operating room should allow for more rational management of dosing and reversal of NMBAs. Furthermore, if incomplete neuromuscular recovery is detected at the end of a surgical procedure, tracheal extubation can be delayed until full recovery of muscle strength has occurred. Therefore, fewer patients should leave the operating room with muscle weakness, and the risks/complications of residual blockade in the PACU reduced. The aim of this clinical investigation is to determine whether EMG monitoring in the operating room reduces the incidence of postoperative residual blockade (measured at the time of tracheal extubation and on arrival to the PACU). During the PACU admission, patients will also be assessed for potential complications related to incomplete neuromuscular recovery (signs and symptoms of muscle weakness, episodes of hypoxemia and airway obstruction, prolonged PACU length of stay). Patients will be randomized to receive either electromyography monitoring (EMG group-TetraGraph) or qualitative peripheral nerve stimulator monitoring (PNS group) in the operating room. The primary endpoint is the incidence of postoperative residual block (defined as a TOF ratio \< 0.9 with the TOF-Watch monitor). Secondary endpoints include a variety of clinical recovery variables listed below.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Postoperative Residual Neuromuscular Blockade

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Patients will be randomized to a qualitative (peripheral nerve stimulator) or quantitative (Tetragraph) monitor
Primary Study Purpose

PREVENTION

Blinding Strategy

SINGLE

Participants
Patients will be under anesthesia and unaware of type of monitoring used in the operating room

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Tetragraph

Patients will be randomized to receive quantitative monitoring in the operating room. Neuromuscular management will be guided by information provided by the monitor

Group Type EXPERIMENTAL

Tetragraph quantitative monitoring

Intervention Type DEVICE

Neuromuscular monitoring will be guided by information provided by the Tetragraph

Qualitative monitoring

The screen of the Tetragraph will be covered so that information is not provided to the clinician. The monitor will therefore function as a standard peripheral nerve monitor (clinicians will only observe the response to nerve stimulation)

Group Type ACTIVE_COMPARATOR

Tetragraph quantitative monitoring

Intervention Type DEVICE

Neuromuscular monitoring will be guided by information provided by the Tetragraph

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Tetragraph quantitative monitoring

Neuromuscular monitoring will be guided by information provided by the Tetragraph

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

\-

Exclusion Criteria

presence of an underlying neuromuscular disease; use of drugs known to interfere with neuromuscular transmission (antiseizure medications, anticholinesterases, magnesium sulfate); renal insufficiency (serum creatinine \> 1.8 mg/dL) or renal failure.
Minimum Eligible Age

18 Years

Maximum Eligible Age

90 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Endeavor Health

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Glenn S Murphy, MD

Role: PRINCIPAL_INVESTIGATOR

Endeavor Health

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

NorthShore University HealthSystem

Evanston, Illinois, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

EH13-032

Identifier Type: -

Identifier Source: org_study_id