Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The total iodine load (TIL) is regarded as a decisive factor in the opacification of parenchymal structures. The EICAR trial demonstrated that injection with high flow rates of prewarmed contrast media (CM) was safe and patients did not experience any pain, stress of discomfort during injection. Flow rates as high as 8.8 ml/s were injected without any discomfort. All concentrations used (e.g. 240, 300 and 370 mg I/ml) in this study were prewarmed. According to the recent recommendations (ESUR guidelines 10.0) it should be considered to warm iodine-based CM before administration. The hypothesis is that although using CM at room temperature (\~23°C \[\~73°F\]) might result in lower attenuation of the liver parenchyma than would be achieved using CM pre-warmed to body temperature, diagnostic image quality, patient safety and comfort will not be compromised by not pre-warming CM in this setting. According to the guidelines, it is regarded as best clinical practice to pre-warm CM. Surprisingly, these recommendations are merely based on a hypothetical assumption. In the literature, there are no studies evaluating this topic and it has never been clearly shown to result in a better patient comfort. For this reason, many clinics do not pre-warm their CM in daily clinical routine. Only one study evaluated subjective comfort in hysterosalpingography (HSG), in which CM is injected in to the cavity of the uterus. This study found that prewarmed CM alleviates the pain and decreased the incidence of vasovagal episodes during HSG. To the best of our knowledge, no study showed that prewarmed CM in CT resulted in higher patient comfort, in comparison to CM at room temperature (20° C).
Up till now, all CM in the department is prewarmed. In case this study does not show a difference in patient comfort, prewarming the CM can be stopped, resulting in a considerable simplified workflow.
The hypothesis is that usage of CM at room temperature (20° C) might result in a decreased level of patient comfort in abdominal CT, in comparison to pre-heated (37° C) CM, with no significant difference in diagnostic attenuation of the liver parenchyma between groups.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effects of Contrast Media Temperature on Image Quality and Clinical Adverse Events in Coronary CTA
NCT05489055
Study of Iodine Contrast Media Extravasation
NCT03426735
Relationship Between Contrast Media Volume and Tube Voltage in CT for Optimal Liver Enhancement, Based on Body Weight.
NCT03735706
Catheter Tip Position and Contrast Distribution Following Paravertebral Catheter Insertion: a CT Study
NCT07064317
Evaluation of Contrast Medium Enhanced Post-mortem CT in Virtual Autopsy
NCT01541995
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
According to the recent recommendations (ESUR guidelines 10.0) it is advised to warm iodine-based CM before administration. Warming the CM is expected to result in a higher patient comfort, based on clinical observation. Kok et al. showed in phantom experiments that high temperature, low iodine concentration and low viscosity significantly decreases injection pressure. Subsequently, as increased temperature reduces the viscosity of the CM, the decreased viscosity is hypothesized to reduce the risk of extravasation. A decreased viscosity might also have a substantial impact on individual tailored CM injection protocols in daily routine scanning as it is speculated that a decrease of viscosity and subsequent decrease in peak injection pressure could influence patient comfort during injection. The EICAR trial showed that prewarmed CM can be safely injected at high flow rates, without patient discomfort, pain or stress. However, the latter was not compared to CM at room temperature.
Different CM concentrations are used in different hospitals throughout the world. The higher the concentration, the higher the viscosity of the CM. In present study, only one CM concentrations (e.g. 300 mg/ml) will be used, which is used in daily clinical practice for years. Heating the CM decreases the viscosity. It is therefore expected that the preheated CM in a concentration of 300 mg/ml has a lower viscosity in comparison to the CM at 20° C.
Pre-warming CM might be regarded as best clinical practice. No studies have been performed to investigate this statement, nor is there any literature that shows that prewarmed CM has a favorable patient comfort compared to CM injected at room temperature. For these reasons, there remains to be some reluctance and many clinics still not pre-warm their CM. One study, in which CM is injected in to the cavity of the uterus to check for any anatomical variants and causes for infertility, showed a preference for prewarmed CM in hysterosalpingography (HCG). This study found that prewarmed CM alleviates the pain and decreased the incidence of vasovagal episode during the HCG.
The hypothesis is that although using CM at room temperature (\~23°C \[\~73°F\]) might result in lower attenuation of the liver parenchyma than would be achieved using CM pre-warmed to body temperature, diagnostic image quality, patient safety and comfort will not be compromised by not pre-warming CM in this setting. Pre-warming CM requires special equipment and more complex planning and logistics. On the other hand, pre-warming CM may yield higher attenuation levels, comfort and image quality. In case this study does not show a significant difference in patient comfort and diagnostic quality between groups, pre-warming the CM can be stopped, resulting in a considerable simplified workflow.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
We are aiming to prospectively enrol 216 consecutive patients, who will be scheduled for contrast enhanced abdominal CT.
216 patients will be divided into 2 different groups:
* Group I: 300 mg/ml at a temperature of 20° C
* Group II: 300 mg/ml at a temperature of 37° C Iodine concentrated CM of 300 mg/ml is clinically used as a standard routine injection protocol for all CT scans in our department, including abdominal CT. The scan protocol is identical to our daily clinical practice. The only difference is that 50% of the included patients will receive CM warmed at room temperature. Both CM temperatures are saved/warmed in an incubator.
OTHER
DOUBLE
The randomization schedule will be prepared and centrally administered. A computer random number generator prepares the randomization schedule in a 1:1 fashion (balanced randomization). Stratification is performed, based on age (\< 60 and ≥ 60 years) and weight (\< 80 and ≥ 80 kg). Variable block randomization will distribute patients equally over time.
The blinding and randomization process will be conducted by Clinical Trial Centre Maastricht (CTCM, www.CTCM.nl) with a randomization program designed for usage of different techniques (minimization, block method, biased-coin, etc). The technician who administers the CM is aware of the CM temperature. Therefore, the technicians will be instructed before start of the study, not to give this information to the patient, not even when requested by the patient.
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
CM temperature 20° C
CM is administered to the patient at a temperature of 20° C.
CM Temperature (20° C)
CM will be administered at 20° C (room temperature).
Weight
The patients' weight is measured prior to scanning by a technician on a weighing scale available in the scanner room.
CM temperature 37° C
CM is administered to the patient at a temperature of 37° C.
CM Temperature (37° C)
CM will be administered at 37° C (pre-heated).
Weight
The patients' weight is measured prior to scanning by a technician on a weighing scale available in the scanner room.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
CM Temperature (20° C)
CM will be administered at 20° C (room temperature).
CM Temperature (37° C)
CM will be administered at 37° C (pre-heated).
Weight
The patients' weight is measured prior to scanning by a technician on a weighing scale available in the scanner room.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Patient ≥ 18 years old and competent to sign informed consent
Exclusion Criteria
* Pregnancy
* Renal insufficiency defined as glomerular filtration rate (GFR) \< 30ml/min/1.73m2 (Odin protocol 004720)
* Iodine allergy (Odin protocol 022199)
* Age \< 18 year
* Unable to give informed consent or no informed consent obtained
* Inability to position an 18 gauge cannula in an antecubital vein
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Maastricht University Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Joachim E Wildberger, Professor
Role: PRINCIPAL_INVESTIGATOR
Maastricht University Medical Center
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
MaastrichtUMC
Maastricht, Limburg, Netherlands
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Martens B, Wildberger JE, Van Kuijk SMJ, De Vos-Geelen J, Jeukens CRLPN, Mihl C. Influence of Contrast Material Temperature on Patient Comfort and Image Quality in Computed Tomography of the Abdomen: A Randomized Controlled Trial. Invest Radiol. 2022 Feb 1;57(2):85-89. doi: 10.1097/RLI.0000000000000807.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
NL68789.068.19
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.