Hemodynamics Measurement in Radiofrequency Catheter Ablation

NCT ID: NCT04227119

Last Updated: 2021-06-14

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

11 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-01-23

Study Completion Date

2020-05-18

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This study will occur in patients undergoing routine cardiac ablation of his/her arrhythmia with planned use of an irrigated ablation catheter. The main objective of this study is to take intracardiac pressure measurements and pressure waveforms with both a "gold standard" balloon tipped pulmonary artery catheter placed for this study and an irrigated ablation catheter placed as standard of care for the procedure.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Measuring internal heart pressures allows for the assessment and diagnosis of a variety of cardiac conditions which are commonly found in patients undergoing catheter ablation, including congestive heart failure, diastolic dysfunction, and valvular heart disease. Currently it is unknown if taking pressure measurements with the ablation catheter is accurate and it is not standard practice to insert the additional 'gold standard' pressure sensing catheter. Catheter ablation of cardiac arrhythmia is performed to offer symptomatic relief from a variety of atrial, ventricular and atrio-ventricular rhythms. Irrigated ablation catheters are commonly used for ablation of arrhythmias arising from the left heart and coronary sinus. These catheters contain internal channels allowing for infusion of an external fluid directly to the tip of the catheter, where the fluid is sprayed through numerous end holes allowing for cooling of the catheter ablation tip.

Fluid filled catheters are also the primary tool utilized to assess intravascular and intracardiac pressures and hemodynamics in the cardiac catheterization suite and intensive care unit. However, the fluid filled catheters commonly used for these assessments are single lumen with a single end hole and generally have a larger minimal diameters compared to the ablation catheter. "Dampening" of pressure waveforms are observed in smaller diameter catheters and may lead to underestimation of peak pressure and overestimation of the nadir pressure gradient. It is unknown if transduction of pressures from the tip of an irrigated ablation catheter will yield equivalent results compared to use of a single 5 French (5F) sized lumen catheter.

This study will seek to enroll patients already scheduled to have a cardiac ablation for a clinical arrhythmia at Emory University Hospital. After completion of the standard ablation, the ablation catheter will be positioned in the heart and pressures will be measured. Next, a standard pressure sensing catheter will be positioned in the same area in the heart and pressures will be measured. The pressure values for each heart chamber assessed will be compared between the catheters. The purpose of this study is to test the hypothesis that transduction of intracardiac pressures using an irrigated ablation catheter placed as standard of care for the ablation procedure is equivalent to transduction of pressures using a standard 5F balloon tipped PA catheter placed only for this research study.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cardiac Arrhythmia

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Irrigated ablation catheter and 5F balloon tipped PA catheter

Participants undergoing cardiac ablation will have cardiac pressures measured with an irrigated ablation catheter (standard protocol for this procedure) and a 5F balloon tipped pulmonary artery (PA) catheter (for study purposes only).

Group Type EXPERIMENTAL

Irrigated ablation catheter

Intervention Type DEVICE

After completion of ablation, the ablation catheter will be serially positioned in the cardiac chambers (either the left or right side of the heart). The stop cock will be turned to the pressure transducer and waveforms will be stored corresponding to each chamber.

Balloon tipped PA catheter

Intervention Type DEVICE

After removal of the irrigated ablation catheter, a 5F balloon tipped PA catheter which will be positioned under fluoroscopic guidance in each previously evaluated chamber and the chambers will be measured again.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Irrigated ablation catheter

After completion of ablation, the ablation catheter will be serially positioned in the cardiac chambers (either the left or right side of the heart). The stop cock will be turned to the pressure transducer and waveforms will be stored corresponding to each chamber.

Intervention Type DEVICE

Balloon tipped PA catheter

After removal of the irrigated ablation catheter, a 5F balloon tipped PA catheter which will be positioned under fluoroscopic guidance in each previously evaluated chamber and the chambers will be measured again.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* patient undergoing routine cardiac ablation of his/her arrhythmia with planned use of an irrigated ablation catheter

Exclusion Criteria

* inability to provide informed consent
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Emory University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Anand D Shah

Assistant Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Anand D Shah, MD

Role: PRINCIPAL_INVESTIGATOR

Emory University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Emory Clinic

Atlanta, Georgia, United States

Site Status

Emory University Hospital

Atlanta, Georgia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

Provided Documents

Download supplemental materials such as informed consent forms, study protocols, or participant manuals.

Document Type: Study Protocol and Statistical Analysis Plan

View Document

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

IRB00116832

Identifier Type: -

Identifier Source: org_study_id