Servo Controlled Oxygen Targeting Study

NCT ID: NCT04177992

Last Updated: 2022-03-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

22 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-01-16

Study Completion Date

2021-01-06

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Most premature babies require oxygen therapy. There is uncertainty about what oxygen levels are the best. The oxygen levels in the blood are measured using a monitor called a saturation monitor and the oxygen the baby breathes is adjusted to keep the level in a target range. Although there is evidence that lower oxygen levels maybe harmful, it is not known how high they need to be for maximum benefit. Very high levels are also harmful. Saturation monitors are not very good for checking for high oxygen levels. For this a different kind of monitor, called a transcutaneous monitor, is better.

Keeping oxygen levels stable is usually done by nurses adjusting the oxygen levels by hand (manual control). There is also equipment available that can do this automatically (servo control). It is not known which is best.

Studies of automated control have shown that infants spend more time within their intended target oxygen saturation range. These have not included measurements of transcutaneous oxygen.

The investigators aim to show the transcutaneous oxygen levels as well as the oxygen saturation levels when babies have their oxygen adjusted manually or automatically.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Presently oxygen is titrated against saturation (SpO2) by manual adjustment. Automated or servo-control systems have been developed that result in tighter control of SpO2 and more time spent in the intended target range. These systems are already in clinical use. Automated systems produce quite large fluctuations in fraction of inspired oxygen (FiO2) in order to keep SpO2 in range. It is possible that this could result in short periods of high or low oxygen tension (PO2) that are undetectable using saturation monitoring. Studies to date have examined the effects of manual and automated (servo) oxygen targeting on SpO2 but not on transcutaneous oxygen tension (TcPO2).

There is a need to determine the achieved SpO2 and TcPO2 distributions associated with the use of manual and automated control as a first step in planning trials comparing these approaches over many weeks. When this is measured over a small number of hours it is not anticipated that this would have an influence on clinical outcome.

This study is a prospective, single centre, randomised crossover trial of automated (servo) control versus manual oxygen titration. Each infant will act as their own control. Infants born at less than 29 weeks gestation, greater than 48 hour of age and receiving supplementary oxygen will be eligible for inclusion.

The study will be undertaken in the Neonatal Unit at the Simpson Centre for Reproductive Health at the Royal Infirmary of Edinburgh.

Total study time is 12 hours for each infant. Infants will be randomised to commence on either automated (servo) control or manual mode. SpO2 (range 90-95%) will be continuously monitored as per normal standard of care. A second pulse oximetry probe will be place for servo control input.

Additional monitoring will be carried out as shown below:

1. TcPO2 monitoring
2. FiO2 monitoring
3. Heart rate monitoring (used to validate SpO2 readings)
4. Arterial gas sampling (only if conducted by the direct care team as part of the routine care of the infant; no extra blood samples will be taken as part of the study)

In manual mode, all oxygen adjustments will be made by clinical/nursing staff. In automated mode, oxygen will be adjusted by the respiratory support device.

In automated mode (servo control), oxygen adjustments will be made by one of two devices (depending on the clinical requirements of the baby) - the IntellO2 device (IntellO2, Vapotherm) or Leoni plus CLAC (Closed-Loop Automated oxygen Control) ventilator (Leoni plus, Löwenstein Medical).

SpO2 and TcPO2 readings will be downloaded directly from the multiparameter patient monitor. SpO2 will be measured using a Phillips MX500 multiparameter monitor. TcPO2 will be measured using a SenTec Digital Monitoring System with OxiVent sensor. TcPO2 is calculated by dynamic fluorescence quenching which measures oxygen molecules present in the vicinity of a fluorescent dye incorporated within the sensor surface. The sensor is operated at a constant temperature of 43 degrees Celsius. Control of sensor temperature and application duration are designed to meet all applicable standards and this monitoring device is used routinely in many neonatal units.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Premature Infant Oxygen Therapy Hypoxia Hyperoxia Obstetric Labor, Premature

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

This is a randomised cross-over study of servo-controlled oxygen targeting in premature infants, with infants acting as their own controls.
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

The study is randomised but not blinded. Infants will be randomised to commence on either automated (servo) control or manual mode, and then cross-over to the alternative range after 6 hours of monitoring (total study time of 12 hours). SpO2 (range 90-95%) will be continuously monitored as per normal standard of care.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Servo control

Automated control of oxygen. The oxygen saturation target range will be set to 93%.

Automated oxygen control can be over-ridden by manual adjustment of oxygen at any time if this is considered necessary to optimise control of oxygenation according to current clinical targets.

Group Type EXPERIMENTAL

Servo control

Intervention Type OTHER

FiO2 adjustments will be made by one of two respiratory devices depending on the clinical requirements and current ventilatory therapy of the infant

Manual control

Standard practice. Oxygen adjustments will be made by clinical/nursing staff to maintain a target oxygen range of 90%-95%.

Group Type NO_INTERVENTION

No interventions assigned to this group

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Servo control

FiO2 adjustments will be made by one of two respiratory devices depending on the clinical requirements and current ventilatory therapy of the infant

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Infants born at less than 29 weeks gestation
2. Infants greater than 48 hours of age
3. Infants who are receiving supplementary oxygen
4. Person with parental responsibility able to give consent

Exclusion Criteria

1. Congenital anomalies that would prevent targeting SpO2 to 90-95% (e.g. cardiac defects)
2. Clinical condition of an infant would impair accurateTcPO2 measurement (e.g. impaired perfusion or requirement of inotropic or vasopressor support)
Maximum Eligible Age

1 Month

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

NHS Lothian

OTHER_GOV

Sponsor Role collaborator

University of Edinburgh

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

The Simpson Centre for Reproductive Health, Royal Infirmary Edinburgh

Edinburgh, , United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

AC19110

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

NICU Oxygen Control Study
NCT04269161 COMPLETED NA
PRICO: OPTI Target Range
NCT06207994 RECRUITING NA