Comparison Between Three Supraglottic Airway Devices ProSeal Laryngeal Mask Airway, Air-Q LMA and Ambu AuraGain

NCT ID: NCT04045899

Last Updated: 2019-08-06

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

150 participants

Study Classification

INTERVENTIONAL

Study Start Date

2016-11-30

Study Completion Date

2018-08-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The present study entitled, "A Randomized Controlled Study Comparing ProSeal Laryngeal Mask Airway, Air-Q LMA and Ambu AuraGain in mechanically ventilated patients." was conducted in during the period Nov 2016 - Aug 2018.

The Aim of the study was to compare the clinical performance of ProSeal-LMA (P-LMA) ,Air-Q and Ambu AuraGain in terms of efficacy and safety in anaesthetized and paralyzed patients on mechanical ventilation undergoing elective surgical procedures.

Objective was to study the three supraglottic devices with respect to following parameters:-number of insertion attempts and overall success rate, ease of insertion of device, time taken for placement of device, airway sealing pressure, glottic view, number of attempts of gastric tube placement, hemodynamic parameters: heart rate and mean arterial pressure: pre-insertion and 0,1,3,5 and 10 minutes post insertion and complications noted if any: blood staining of device and tongue, lip and dental trauma, laryngospasm ,sore throat, dysphagia, hoarseness of voice.

It was a randomized prospective single blind comparative study comprised of 150 ASA I - II patients, aged 18-65 years of either sex who weighed between 40 to 60 kg scheduled for elective surgical procedure of duration not more than 90 mins. After a thorough pre-anaesthetic check-up, informed written consent was obtained and the patients were randomized into 3 groups of 50 patients each as Group P(Proseal), Group Q (Air Q) and Group A (AuraGain) by computer generated randomization sequence.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In this study PLMA, Air-Q® and Ambu AuraGain were compared undergoing elective surgeries under general anaesthesia. Primary outcome measure was insertion time. Airway sealing pressure,ease of insertion, number of attempts,overall success rate, glottis view,number of attempts of gastric tube placement , hemodynamic parameters and complications were also compared.

After approval from the institutional ethical committee, 150 patients were studied in a randomised prospective study, designed to compare PLMA , Air-Q® and Ambu AuraGain .The period of the study was from nov 2016 to aug 2018. This study was conducted according to Good Clinical Practice standards and the Helsinki Declaration.

The American Society of Anesthesiologists (ASA) physical status I and II patients, between 18-65 years of age, weighing from 40 to 60 kg of either sex, undergoing elective surgical procedures of duration not more than 90 minutes were selected for the study. The exclusion criteria included patients with anticipated difficult airway (mouth opening of \<2 finger, Mallampati Score 4, limited neck extension, history of previous difficult intubation), upper respiratory tract infections,airway related conditions such as trismus, trauma or mass, cervical spine disease, obese with body mass index (BMI) ≥25kg/m2 ,pregnant females, patients at risk of aspiration (full stomach, hiatus hernia, gastro-oesophageal reflux disease, emergency surgery)and laparoscopic surgeries. Neck movement was assessed as Class: I-No reduction in movement, II-1/3rd reduction, III-2/3rd reduction, IV-Complete reduction.

Following detailed pre-anaesthetic check-up, informed written consent was obtained from all patients fulfilling the required criteria.Patients were randomly allocated into three groups namely Group P(ProSeal,n=50) ,Group Q (Air-Q®, n = 50) and Group A (AuraGain™, n = 50) using computer-generated randomisation sequence. Participants were assigned to specific groups by the operating room nurse in charge.

After attaching the standard monitors(ASA recommended), patients were pre-medicated with injection midazolam 0.05 mg/kg, glycopyrrolate 0.2 mg, dexamethasone 4 mg and nalbuphine 0.02mg/kg intravenously. All patients were pre-oxygenated for 3 min, and anaesthesia was induced with injection propofol 2 mg/kg. Injection vecuronium 0.1 mg/kg was given for neuromuscular blockade.

PLMA or Air-Q® or AuraGain™ appropriate for weight or/and height was inserted as per the manufacturers guidelines.After successful insertion, the cuff was inflated with air according to the size and type of LMA as per manufacturers guidelines, to prevent audible and palpable air leak. An effective airway was confirmed by bilateral symmetrical chest expansion on manual ventilation, auscultation of breath sounds, square waveform on capnography. Devices were fixed with adhesive tape applied to the maxilla on one side of the patient's face and passed over and under the tube in a single loop before fixing to the opposite maxilla.

Anaesthesia was maintained with oxygen, nitrous oxide and isoflurane and intermittent positive pressure ventilation. Haemodynamic parameters\[heart rate(HR), mean arterial pressure(MAP)\]were monitored before and after the insertion of the device. A lubricated gastric tube was placed in the stomach through the gastric channel. At the end of surgical procedure, anaesthesia was discontinued and residual neuromuscular blockade reversed with injection neostigmine and glycopyrrolate, followed by device removal. Complication if any was noted.

Insertion time, number of insertion attempts, overall success rate, ease of insertion, airway sealing pressure, glottis view, number of attempts of gastric tube insertion, hemodynamic parameters (HR and MAP) preinduction, induction and 1,3,5 and 10mins post induction and complications were noted. One attempt was defined as insertion of the LMA between the teeth until the LMA will be deemed to be correctly placed and its cuff will be properly inflated. In case of insertion attempts, maximum of three attempts were allowed. An attempt was considered unsuccessful, if there was failure to negotiate the device beyond oropharynx, significant leak present (both audible and auscultatory) or inadequate ventilation with EtCO2\>45 mmHg. Failure of a device was defined as three unsuccessful insertion attempts or inadequate ventilation. After failure of three attempts, intubation was performed using conventional rigid laryngoscopy and case was recorded as failed and also deleted from the study. The ease of insertion of device based on Visual Analogue Scale(VAS) was recorded.0 was considered the easiest insertion of device and 10 being the most difficult insertion.Insertion time was defined as time interval (in seconds) elapsed from insertion of LMA between the dental arches until the confirmation of successful ventilation determined by chest wall movement, auscultation of breath sounds and square wave capnographic curves and no oropharyngeal leak with peak airway pressure ≥ 20cmH2O, which was recorded by an independent observer.The airway sealing pressure was measured by closing the expiratory valve of the circle system at a fixed gas flow of 3 L/min and recording the airway pressure at which equilibrium is reached. At this stage, a leak at mouth and stomach was ascertained. Glottic viewing was assessed by insertion of the fibreoptic bronchoscope through the airway channel of the respective LMA.A maximum of two attempts were allowed for gastric tube placement. Its correct placement was confirmed by injection of air and epigastric auscultation or aspiration of gastric contents. Failure was defined as inability to advance the orogastric tube into the stomach within two attempts. Blood staining of the device and tongue, lip or dental trauma was noted. Incidence of laryngospasm or hypoxia (defined as oxygen saturation \<92%), if any, in intra-operative period was noted and managed accordingly. In post-operative period, an investigator blinded to study asked the patients about the signs of sore throat, dysphagia and hoarseness of voice. Incidence of hoarseness and sore throat, whether present or absent, were enquired in 24 h post-operatively.

The primary outcome measure of the study was insertion time. Based on a previous study investigators found mean insertion time in PLMA group was 23.43 seconds and SD of 3.54. Based on that, taking alpha 0.05, β =0.90 and 25% difference between the means as significant, investigators calculated 47 patients were required in each group; hence, the sample size was increased to 50 patients each.

The data were recorded in a Microsoft Excel Spreadsheet and analysed using SPSS statistics software version 24 (IBM SPSS Inc., Chicago, IL, USA). Continuous numerical variables were presented as mean (standard deviation) and intergroup differences were compared using one-way analysis of variance with post hoc correction. Categorical variables were presented as ratio or as n (%) and inter-group differences were compared using Kruskall-Wallis test. The P\< 0.05 was considered statistically significant.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Proseal LMA vs Air-Q LMA vs Ambu AurGain LMA

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Methods:This prospective, randomised, single-blind study was conducted on 150 American Society of Anesthesiologists physical status I-II, randomly allocated into 3 groups, undergoing elective surgical procedures under general anaesthesia.PLMATM, Air-Q® and Ambu AuraGainTM appropriate for weight or/and height was inserted.Primary outcome measure was insertion time.Airway sealing pressure,ease of insertion, number of attempts,overall success rate, glottis view,number of attempts of gastric tube placement , hemodynamic parameters and complications were also recorded.
Primary Study Purpose

OTHER

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

ProSeal Laryngeal Mask Airway Group

ProSeal LMA was inserted in 50 patients

Group Type ACTIVE_COMPARATOR

Proseal LMA

Intervention Type DEVICE

The Proseal Laryngeal Mask Airway (p-LMA) has a dual cuff modified to provide better sealing, and a drainage tube for gastric tube insertion. These features attribute in increasing the safety of the p-LMA when used with positive pressure ventilation.

Air-Q LMA Group

Air-Q LMA was inserted in 50 patients

Group Type EXPERIMENTAL

Air-Q LMA

Intervention Type DEVICE

Air-Q LMA has a self-pressurizing cuff which inflates to adequate pressure during positive pressure ventilation thus eliminating the adverse effects of cuff over inflation associated with the use of Supraglottic airway device with an inflatable cuff.

Ambu AuraGain LMA Group

Ambu AuraGain was inserted in 50 patients

Group Type EXPERIMENTAL

Ambu AuraGain LMA

Intervention Type DEVICE

The AmbuAuraGain™ is a disposable, preformed second generation SAD, anatomically curved with integrated gastric access and intubation capability, taking patient safety and airway management efficiency to a new level.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Proseal LMA

The Proseal Laryngeal Mask Airway (p-LMA) has a dual cuff modified to provide better sealing, and a drainage tube for gastric tube insertion. These features attribute in increasing the safety of the p-LMA when used with positive pressure ventilation.

Intervention Type DEVICE

Air-Q LMA

Air-Q LMA has a self-pressurizing cuff which inflates to adequate pressure during positive pressure ventilation thus eliminating the adverse effects of cuff over inflation associated with the use of Supraglottic airway device with an inflatable cuff.

Intervention Type DEVICE

Ambu AuraGain LMA

The AmbuAuraGain™ is a disposable, preformed second generation SAD, anatomically curved with integrated gastric access and intubation capability, taking patient safety and airway management efficiency to a new level.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age 18-65 years of either sex.
* Weight between 40-60 kg of either sex.
* Elective Surgical procedures of duration not more than 90 minutes with no need for endotracheal intubation.

Exclusion Criteria

* • Patients with anticipated difficult airway(Mouth opening of \<2 finger, Mallampati class 4,limited neck extension, history of previous difficult intubation).

* Restricted mouth opening
* Pregnant females
* Cervical spine disease
* Obese with body mass index ≥25kg/m2.
* Patients with upper respiratory tract infections.
* Patients at the risk of gastroesophageal regurgitation (eg hiatus hernia,sepsis, Diabetes Mellitus,obesity,pregnancy or a history of upper gastrointestinal surgery)
* Laparoscopic surgeries
* Patients with airway related conditions such as trismus,trauma or mass.
Minimum Eligible Age

18 Years

Maximum Eligible Age

65 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Dr.Mahak Mehta

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dr.Mahak Mehta

POST GRADUATE STUDENT

Responsibility Role SPONSOR_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

MAHAK MEHTA, MD

Role: PRINCIPAL_INVESTIGATOR

M.B.B.S M.D Anaesthesia GMC Haldwani(Nainital)

References

Explore related publications, articles, or registry entries linked to this study.

1. Sood J. Laryngeal mask airway and its variants. Indian J Anaesth. 2005;49(4):275-80.

Reference Type BACKGROUND

Singh K, Gurha P. Comparative evaluation of Ambu AuraGain with ProSeal laryngeal mask airway in patients undergoing laparoscopic cholecystectomy. Indian J Anaesth. 2017 Jun;61(6):469-474. doi: 10.4103/ija.IJA_163_17.

Reference Type BACKGROUND
PMID: 28655951 (View on PubMed)

Seet E, Rajeev S, Firoz T, Yousaf F, Wong J, Wong DT, Chung F. Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial. Eur J Anaesthesiol. 2010 Jul;27(7):602-7. doi: 10.1097/eja.0b013e32833679e3.

Reference Type BACKGROUND
PMID: 20540172 (View on PubMed)

13. Soliman HF. Insertion characteristics of three supraglottic airway devices: A randomized comparative trial. Ain-Shams J Anaesthesiol. 2016;9(2):212-8.

Reference Type BACKGROUND

14.Abdel-Halim TM, El Enin MA, Elgoushi MM, Afifi MG, Atwa HS. Comparative study between Air-Q and Intubating Laryngeal Mask Airway when used as conduit for fiber-optic. Egyptian J Anaesth. 2014;30(2):107-13.

Reference Type BACKGROUND

Brimacombe J, Keller C. The ProSeal laryngeal mask airway. Anesthesiol Clin North Am. 2002 Dec;20(4):871-91. doi: 10.1016/s0889-8537(02)00044-5.

Reference Type BACKGROUND
PMID: 12512267 (View on PubMed)

Brimacombe J, Keller C, Boehler M, Puhringer F. Positive pressure ventilation with the ProSeal versus classic laryngeal mask airway: a randomized, crossover study of healthy female patients. Anesth Analg. 2001 Nov;93(5):1351-3, table of contents. doi: 10.1097/00000539-200111000-00064.

Reference Type BACKGROUND
PMID: 11682428 (View on PubMed)

Galgon RE, Schroeder KM, Han S, Andrei A, Joffe AM. The air-Q((R)) intubating laryngeal airway vs the LMA-ProSeal(TM) : a prospective, randomised trial of airway seal pressure. Anaesthesia. 2011 Dec;66(12):1093-100. doi: 10.1111/j.1365-2044.2011.06863.x. Epub 2011 Aug 22.

Reference Type RESULT
PMID: 21880031 (View on PubMed)

Jagannathan N, Hajduk J, Sohn L, Huang A, Sawardekar A, Gebhardt ER, Johnson K, De Oliveira GS. A randomised comparison of the Ambu(R) AuraGain and the LMA(R) supreme in infants and children. Anaesthesia. 2016 Feb;71(2):205-12. doi: 10.1111/anae.13330. Epub 2015 Dec 9.

Reference Type RESULT
PMID: 26648173 (View on PubMed)

4. Youssef MM, Lofty M, Hammad Y, Elmenshawy E. Comparative study between LMA-Proseal™ and Air-Q® Blocker for ventilation in adult eye trauma patients. Egyptian J Anaesth. 2014;30(3):227-33.

Reference Type RESULT

5. Sethi S, Maitra S, Saini V, Samara T. Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: a randomized controlled trial. Egyptian J Anaesthes. 2017;33(2):137-40.

Reference Type RESULT

Joshi R, Rudingwa P, Kundra P, Panneerselvam S, Mishra SK. Comparision of Ambu AuraGain and LMA(R) ProSeal in children under controlled ventilation. Indian J Anaesth. 2018 Jun;62(6):455-460. doi: 10.4103/ija.IJA_86_18.

Reference Type RESULT
PMID: 29962528 (View on PubMed)

Brimacombe J, Keller C, Fullekrug B, Agro F, Rosenblatt W, Dierdorf SF, Garcia de Lucas E, Capdevilla X, Brimacombe N. A multicenter study comparing the ProSeal and Classic laryngeal mask airway in anesthetized, nonparalyzed patients. Anesthesiology. 2002 Feb;96(2):289-95. doi: 10.1097/00000542-200202000-00011.

Reference Type RESULT
PMID: 11818758 (View on PubMed)

Parikh DA, Jain RA, Lele SS, Tendolkar BA. A cohort evaluation of clinical use and performance characteristics of Ambu(R) AuraGain: A prospective observational study. Indian J Anaesth. 2017 Aug;61(8):636-642. doi: 10.4103/ija.IJA_285_17.

Reference Type RESULT
PMID: 28890558 (View on PubMed)

Wong DT, Ooi A, Singh KP, Dallaire A, Meliana V, Lau J, Chung F, Singh M, Wong J. Comparison of oropharyngeal leak pressure between the Ambu(R) AuraGain and the LMA(R) Supreme supraglottic airways: a randomized-controlled trial. Can J Anaesth. 2018 Jul;65(7):797-805. doi: 10.1007/s12630-018-1120-4. Epub 2018 Mar 26.

Reference Type RESULT
PMID: 29582360 (View on PubMed)

11. Bhandari G, Mitra S, Shahi KS, Chand G, Tyagi A. A comparative study evaluating I-gel and Air-Q LMA for ventilation in anaesthetised and paralysed patients. Ann Int Med Dent Res. 2015;32:25-8.

Reference Type RESULT

Lopez AM, Agusti M, Gambus P, Pons M, Anglada T, Valero R. A randomized comparison of the Ambu AuraGain versus the LMA supreme in patients undergoing gynaecologic laparoscopic surgery. J Clin Monit Comput. 2017 Dec;31(6):1255-1262. doi: 10.1007/s10877-016-9963-0. Epub 2016 Nov 26.

Reference Type RESULT
PMID: 27889843 (View on PubMed)

Darlong V, Biyani G, Pandey R, Baidya DK, Punj Ca. Comparison of performance and efficacy of air-Q intubating laryngeal airway and flexible laryngeal mask airway in anesthetized and paralyzed infants and children. Paediatr Anaesth. 2014 Oct;24(10):1066-71. doi: 10.1111/pan.12462.

Reference Type RESULT
PMID: 24961960 (View on PubMed)

19. Lopez AM, Sala-Blanch X, Valero R, Prats A. Cross-over assessment of the AmbuAuraGain, LMA Supreme New Cuff and Intersurgical I-Gel in fresh cadavers. Open J Anesthesiol. 2014;4(12):332-9.

Reference Type RESULT

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

328/GMC/IEC/2016/Reg.No.280

Identifier Type: -

Identifier Source: org_study_id

More Related Trials